No photo available yet
Nabertherm W 5000/H
Nabertherm W 5000/H — Furnace Solutions 1400 Degc.
Bogie hearth furnace with a 5000-litre chamber (1000 × 3600 × 1400 mm) and wire heating to a 1340 °C maximum, built for loads transferred on a rail-mounted bogie. The /H modification is the high-temperature variant of the W 5000 platform, positioned below the W 7500 in chamber volume within the series. It serves batch heat treatment of heavy, large-footprint charges that cannot be hand-loaded.
Nabertherm Bogie Hearth Furnaces with Wire Heating up to 1400 °C | Nabertherm Series — Model Comparison & Selection
Full specifications
| Chamber volume | 5000 l |
| Chamber volume | 5000 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating power | 235 watt |
| Heating power | 235 watt |
| Inner dimensions (W × D × H) mfr | 1000 × 3600 × 1400 mm |
| Outer dimensions (W × D × H) mfr | 1670 × 4390 × 2520 mm |
| Weight | 7300 kg |
| Weight | 7300 kg |
| Max temperature | 1340 °C |
| Max temperature | 1340 °C |
Description
Construction and series positioning
- Chamber volume 5000 l with inner dimensions 1000 mm wide × 3600 mm deep × 1400 mm high; outer envelope 1670 × 4390 × 2520 mm, unit weight 7300 kg.
- The load is carried on a bogie hearth rather than a fixed floor, so the charge is built up outside the furnace and rolled in — the reason for the long 3600 mm depth relative to width.
- Within the series, the W 5000/H is the high-temperature (/H) version of the 5000-litre size: the W 5000 is the same chamber volume without the /H designation, the W 1500 and W 1500/14 are smaller chambers, and the W 7500 is the next size up. Choose this model when the charge footprint needs the 5000-litre class and the process needs the elevated maximum temperature.
Thermal behaviour
- Wire heating with a stated maximum temperature of 1340 °C; no heating-curve or uniformity data is published for this model, so ramp rates and uniformity must be established per installation.
- The 1400 °C-class furnace family is the reference frame; the model's own ceiling is 1340 °C, and process setpoints should be kept below it with margin for control overshoot.
Electrical and control
- Three-phase connection; the heating power figure in the source data (235 W) is not physically consistent with a 5000-litre 1340 °C furnace and is therefore not quoted here — the actual connected load must be taken from the nameplate/order documents.
- Controller and process-data functions follow the Nabertherm controller series 500 / MyNabertherm documentation (process data storage, temperature-uniformity instrumentation per AMS2750F, recorder options); no controller is specified as part of this model's verified data.
Installation
- At 7300 kg and 2520 mm overall height, the unit requires a prepared floor and sufficient headroom for the bogie travel and door swing; the 4390 mm outer depth includes the hearth extension beyond the 3600 mm chamber.
Integration & Operating Notes
The wire heating is rated to a 1340 °C maximum. Controller overshoot at the end of a ramp can push the chamber above the setpoint, so the working setpoint must leave margin below 1340 °C; sustained operation at the ceiling shortens element life and is outside the published limit.
Nabertherm controller series 500 documentation covers process-data storage, AMS2750F temperature-uniformity instrumentation types and recorder options, but none of these is confirmed as included with this model. Specify the controller, recorder and uniformity class at order time if the process requires documented traces.
Selection & Integration Q&A
Take the /H when the process needs the elevated maximum temperature at 5000 l. The plain W 5000 gives the same 5000-litre chamber without the /H rating; the W 7500 is the larger chamber when charge footprint exceeds 1000 × 3600 mm. The W 1500 sizes are for smaller loads.
The connection is three-phase, but the published power figure is not consistent with this chamber size, so feeder, breaker and isolation must be sized from the unit nameplate and the order-specific connection diagram rather than from the catalogue data.
Controller series 500 functions, AMS2750F uniformity instrumentation and recorders are documented options, not confirmed base delivery — specify them at order. No maintenance interval is published for this model; element and thermocouple condition should be checked per the order documents.