Shimadzu
·Made in Japan
·
In Active Production
Shimadzu MALDI 8020
Shimadzu MALDI 8020 — Mass spectrometers.
The Shimadzu MALDI 8020 is a benchtop linear MALDI-TOF mass spectrometer configured for positive-ion linear mode, using a 355 nm solid-state laser with variable pulse rates of 50, 100, or 200 Hz. It covers a mass range of m/z 1 to 500,000 with resolution greater than 5,000 FWHM and sensitivity better than 250 amol. This modification is intended for routine intact-mass analysis of large biomolecules in a compact laboratory footprint.
Direct drop-in replacements
Full specifications
Core Performance & Functional Specifications
| Type | benchtop, linear MALDI-TOF mass spectrometer (MALDI-8020) |
| Ion source | linear mode (positive ion) MALDI (MALDI-8020) |
| Wavelength | 355 nm (MALDI-8020) |
| Resolution (4.2 kDa peptide, average) mfr | >5000 FWHM (4.2 kDa peptide, average) |
| Flow rate (LCMS single quadrupole, 70-mer DNA analysis) mfr | 0.3 mL/min (LCMS single quadrupole, 70-mer DNA analysis) |
| Detection wavelength range (PDA detection, 70-mer DNA analysis) mfr | 200-400 nm (PDA detection, 70-mer DNA analysis) |
| Ionization mode (LCMS single quadrupole, 70-mer DNA analysis) mfr | ESI/APCI (DUIS), Negative mode (LCMS single quadrupole, 70-mer DNA analysis) |
| Flow rate (LCMS single quadrupole, FLP impurity analysis) mfr | 0.3 mL/min (LCMS single quadrupole, FLP impurity analysis) |
| UV detection wavelength range (LCMS single quadrupole, FLP impurity analysis) mfr | 190-400 nm (LCMS single quadrupole, FLP impurity analysis) |
| Injection volume (LCMS single quadrupole, FLP impurity analysis) mfr | 6 μL (LCMS single quadrupole, FLP impurity analysis) |
| Scan mode (LCMS single quadrupole, FLP impurity analysis) mfr | Scan (m/z 550-2000) (LCMS single quadrupole, FLP impurity analysis) |
| Nebulizing gas flow (LCMS single quadrupole, FLP impurity analysis) mfr | 3.0 L/min (LCMS single quadrupole, FLP impurity analysis) |
| Drying gas flow (LCMS single quadrupole, oligonucleotide impurity analysis) mfr | 5.0 L/min (LCMS single quadrupole, oligonucleotide impurity analysis) |
| Co-injection volumes (Nexera XS inert, co-injection pretreatment) mfr | 1, 3, 5 μL (Nexera XS inert, co-injection pretreatment) |
Dimensions, Weight & Mechanical Design
| Height | 1055 mm (MALDI-8020) |
| Weight | 92 kg (MALDI-8020) |
| Width | 600 mm (MALDI-8020) |
| Depth mfr | 745 mm (MALDI-8020) |
Electrical, Power & Drive Specifications
| Mobile phase A composition (LCMS single quadrupole, 70-mer DNA analysis) mfr | 95.4 mM HFIP, 7.1 mM TEA in water (LCMS single quadrupole, 70-mer DNA analysis) |
| Mobile phase A composition (Nexera XS inert, oligonucleotide impurity analysis) mfr | 100 mmol/L HFIP, 10 mmol/L TEA in water (Nexera XS inert, oligonucleotide impurity analysis) |
| Flow rate (Reversed-phase ion-pair chromatography optimization) mfr | 0.35 mL/min (Reversed-phase ion-pair chromatography optimization) |
Interfaces, Connections & Control
| Interface voltage (LCMS single quadrupole, 70-mer DNA analysis) mfr | -2.0 kV (LCMS single quadrupole, 70-mer DNA analysis) |
Operating Conditions, Environment & Protection
| Noise (quiet operation) mfr | <55 dB (quiet operation) |
Description
Construction and positioning
- Benchtop linear MALDI-TOF architecture with a single solid-state laser (355 nm) and fixed linear positive-ion detection. - The linear mode is optimized for broad mass range (m/z 1–500,000) rather than high-resolution reflectron operation. ### Behavior under load and in different modes
- The laser pulse rate is selectable among 50, 100, and 200 Hz, allowing adjustment of acquisition speed versus sample consumption. - Resolution is specified as >5,000 FWHM, and sensitivity as >250 amol; no curve points or mode-specific performance data are available. - Operation is limited to positive-ion linear mode; no negative-ion or reflectron data is provided. ### Installation, connection, and operation
- No PDF digests or manual excerpts were supplied, so installation, control interfaces, and operating specifics cannot be detailed beyond the listed specifications.