Agilent Technologies Cary 3500 Flexible UV-Vis, Large Sample Compartment
Agilent Technologies Cary 3500 Flexible UV-Vis, Large Sample Compartment — Molecular spectroscopy.
The Cary 3500 Flexible UV-Vis is a large-sample-compartment spectrophotometer for liquid and solid samples, distinct from the Compact and Multicell siblings. Its eight-position cell changer holds seven samples plus a reference, and the 1.5 mm focused beam suits 3.5 mL cuvettes. It serves as the series' open-architecture platform for variable-path-length and solid-sample work.
Agilent Technologies Cary Series — Model Comparison & Selection
| Model | Wavelength range | Focused beam diameter, mm | Integrating sphere diameter, mm | Temperature range, °C |
|---|---|---|---|---|
| Cary 3500 Flexible UV-Vis, Large Sample Compartment Current | — | 1.5 | — | — |
| Cary 3500 | — | 1.5 | — | 5...110 |
| Cary 3500 Compact UV-Vis Spectrophotometer | — | 1.5 | — | 5...110 |
| Cary 4000 UV-Vis | 175...900 | — | 150 | — |
| Cary 5000 UV-Vis-NIR spectrophotometer | 175...900 | — | — | — |
| Cary 60 | 190...1,100 | — | — | — |
| Cary 6000i UV-Vis-NIR | 175...900 | — | 150 | — |
Full specifications
| Cuvette Volume | 3.5 mL |
| Focused Beam Diameter | 1.5 mm |
| Number of cell positions mfr | eight positions positions |
| Maximum samples plus reference mfr | seven samples and a reference reference |
| Microcuvette measurement capacity mfr | eight microcuvettes microcuvettes |
| Flow cell channels mfr | three channels channels |
| Flow cells filled and rinsed simultaneously mfr | three flow cells cells |
| Wavelength range shown mfr | 250...600 nm |
| Path length mfr | 1 cm |
Description
Construction and series positioning
- The Flexible UV-Vis is the large-sample-compartment member of the Cary 3500 series; the Compact and Multicell variants use smaller, enclosed compartments.
- The open compartment accepts a variable-path-length cuvette holder and solid-sample accessories, which the Compact and Multicell configurations do not.
- The cell changer provides eight positions: seven samples plus a reference, or eight microcuvettes.
- A 1.5 mm focused beam diameter is matched to 3.5 mL cuvettes; larger rectangular cells (7, 17.5, 35 mL; 2, 5, 10 cm) and cylindrical cells (2.8, 14.1, 28.2 mL; 1, 5, 10 cm) are listed accessories.
Measurement behavior
- The eight-position changer supports batch sequences without manual cuvette exchange; the reference position allows baseline correction within a run.
- A three-channel flow-cell configuration fills and rinses three flow cells simultaneously, enabling sequential flow measurements.
- The documented wavelength window of 250–600 nm covers UV-Vis dye, nucleic-acid and protein assays; the melting-temperature example (Tm 86.5–87.1 °C) indicates thermal ramping capability when the temperature-controlled accessory is fitted.
- No digitized performance curves were supplied, so photometric accuracy and stray-light behavior cannot be stated here.
Installation and operation
- The large compartment is open by design; the variable-path-length holder is a separate accessory and must be ordered for path-length work.
- Cuvette accessories are supplied with PTFE lids or stoppers; the base delivery does not include cells.
- No electrical, interface or environmental specifications were verified for this model, so supply and control details must be taken from the site-specific configuration.
Integration & Operating Notes
The large sample compartment is empty by default; path-length work requires the dedicated variable-path-length cuvette holder, and solid-sample work requires the corresponding solid-sample accessory. Confirm the holder is on the order before planning 1, 2, 5 or 10 cm measurements.
The 1.5 mm beam diameter is matched to 3.5 mL rectangular cuvettes; larger 7, 17.5 and 35 mL cells and cylindrical cells are listed accessories. Using a cell whose window does not fully intercept the beam will bias absorbance readings.
Batch sequences can be queued across seven sample positions with one reference position for baseline correction, or eight microcuvettes. Plan sample batches around this eight-position limit; larger batches require reloading mid-sequence.
The three-channel flow configuration fills and rinses three flow cells simultaneously; residual sample in the lines after a run will contaminate the next measurement. Include a rinse cycle in the method and verify line cleanliness before switching media.
Selection & Integration Q&A
Choose the Flexible when you need the large open compartment for variable-path-length cuvettes (1–10 cm) or solid samples. The Compact suits routine fixed-path liquid work in a small footprint; the Multicell adds multiple temperature zones for parallel thermal ramps. The Flexible trades enclosure for accessory breadth.
The variable-path-length cuvette holder is a separate accessory and is required for 1, 2, 5 or 10 cm work; the base instrument does not include it. Cuvettes are also not included: rectangular cells with PTFE lids are listed at 3.5, 7, 17.5 and 35 mL for 1, 2, 5 and 10 cm paths.
The three-channel flow configuration fills and rinses three flow cells simultaneously, while the eight-position changer handles seven samples plus a reference or eight microcuvettes. These are separate sample-handling setups; switching between them requires changing the compartment configuration, so plan campaigns accordingly.
The three-channel flow system fills and rinses three flow cells simultaneously; a rinse cycle must be included in the method after each sample set. Residual liquid in the lines will contaminate the next measurement, so verify line cleanliness before switching media or samples.