The Cary 3500 Compact UV-Vis is a double-beam spectrophotometer with an eight-position cell holder (seven samples plus reference) and a 1.5 mm focused beam. It is the compact member of the Cary 3500 series, distinguished from the Multicell and Flexible variants by its small sample compartment and integrated multicell holder. It is used for routine quantitative UV-Vis analysis and temperature-dependent measurements such as DNA melting curves.
Agilent Technologies Cary Series — Model Comparison & Selection
| Model | Wavelength range | Focused beam diameter, mm | Integrating sphere diameter, mm | Temperature range, °C |
|---|---|---|---|---|
| Cary 3500 Compact UV-Vis Spectrophotometer Current | — | 1.5 | — | 5...110 |
| Cary 3500 | — | 1.5 | — | 5...110 |
| Cary 3500 Flexible UV-Vis, Large Sample Compartment | — | 1.5 | — | — |
| Cary 4000 UV-Vis | 175...900 | — | 150 | — |
| Cary 5000 UV-Vis-NIR spectrophotometer | 175...900 | — | — | — |
| Cary 60 | 190...1,100 | — | — | — |
| Cary 6000i UV-Vis-NIR | 175...900 | — | 150 | — |
Full specifications
| Focused Beam Diameter | 1.5 mm |
| Temperature range | 5...110 °C |
| Number of cell positions mfr | eight positions positions |
| Maximum samples plus reference mfr | seven samples and a reference reference |
| Microcuvette measurement capacity mfr | eight microcuvettes microcuvettes |
| Flow cell channels mfr | three channels channels |
| Flow cells filled and rinsed simultaneously mfr | three three |
| Cell positions mfr | eight eight |
| Samples plus reference mfr | seven samples and a reference reference |
| Flow cell pump channels mfr | three three |
| data acquisition rate mfr | 250 second |
| wavelength drive speed mfr | 2500 second |
| spectral bandwidth mfr | 0.1...5 nm |
| path length options mfr | 2 cm |
| lamp replacement warranty mfr | 10 year |
Description
Construction and series positioning
- Double-beam optical architecture with a focused beam diameter of 1.5 mm.
- Eight-position cell holder: seven sample positions plus one reference position; accepts eight microcuvettes.
- Compact sample compartment distinguishes it from the Cary 3500 Flexible (large sample compartment for solid and liquid samples) and the Cary 3500 Multicell (ambient, temperature-controlled, or multiple-temperature-zone configurations).
- The Compact variant is available in ambient or temperature-controlled form; this card covers the temperature-controlled configuration where ramp and Tm data apply.
Measurement behavior
- The eight-position holder allows sequential measurement of seven samples against a single reference without manual cuvette exchange.
- Temperature-controlled operation supports ramp rates from 1 °C/min and melting-temperature determination; reported Tm values of 86.5–87.1 °C indicate the range observed in thermal denaturation experiments.
- A three-channel flow-cell configuration is supported: three flow cells can be filled and rinsed simultaneously, enabling automated flow-through measurements.
Installation and operation
- The focused 1.5 mm beam requires cuvettes positioned accurately in the holder; microcuvette capacity is eight.
- No electrical, interface, or environmental specifications were verified for this model; consult the factory specification sheet for supply and communication details.
Selection & Integration Q&A
Choose the Compact for routine UV-Vis with up to seven samples plus a reference in a small compartment, with optional temperature control for melt curves. Choose the Multicell for multiple independent temperature zones, and the Flexible for large solid samples requiring an extended compartment.
A three-channel flow-cell configuration is supported, with three flow cells filled and rinsed simultaneously. This suits automated flow-through assays; ensure the peristaltic or syringe pump delivers to all three channels in parallel and that rinse steps cover all channels.
Verified data specify a minimum ramp rate of 1 °C/min and Tm values of 86.5–87.1 °C for the reference assay. Ambient temperature range, humidity, and duty-cycle limits are not stated in the verified facts; consult the factory specification sheet before installing in a non-conditioned laboratory.
The base delivery does not include cuvettes or flow cells; eight microcuvettes or a three-channel flow-cell set must be ordered separately. Routine maintenance consists of flushing all three flow-cell channels simultaneously after each run to prevent residue buildup.