Agilent Technologies Cary 3500
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Cary 3500

Agilent Technologies Cary 3500 — Molecular spectroscopy.

The Cary 3500 Multicell UV-Vis is a modular spectrophotometer built from a Xenon-flash dual-monochromator engine and an eight-position Multicell module (seven samples plus reference). It is the multicell modification of the Cary 3500 series, distinguished by simultaneous multi-cuvette measurement; Peltier variants add four independently controlled temperature zones from -5 to 110 °C. It serves high-throughput absorbance and thermal-melting workflows in laboratory molecular spectroscopy.

Agilent Technologies Cary Series — Model Comparison & Selection

Model Wavelength rangeFocused beam diameter, mmIntegrating sphere diameter, mmTemperature range, °C
Cary 3500 Current —1.5—5...110
Cary 3500 Compact UV-Vis Spectrophotometer —1.5—5...110
Cary 3500 Flexible UV-Vis, Large Sample Compartment —1.5——
Cary 4000 UV-Vis 175...900—150—
Cary 5000 UV-Vis-NIR spectrophotometer 175...900———
Cary 60 190...1,100———
Cary 6000i UV-Vis-NIR 175...900—150—

Full specifications

Core Performance & Functional Specifications
Focused Beam Diameter 1.5 mm
Memory 16 RAM
Operating system 10 bit
Temperature range 5...110 °C
Number of cell positions mfr eight positions positions
Maximum samples plus reference mfr seven samples and a reference reference
Microcuvette measurement capacity mfr eight microcuvettes microcuvettes
Flow cell channels mfr three channels channels
Flow cells filled and rinsed simultaneously mfr three three
Measurement category mfr 61010 I
Clearance for Peltier models mfr 20 cm
Rear clearance for Peltier models mfr 10 cm
Clearance for non-Peltier models mfr 10 cm
Rear clearance for non-Peltier models mfr 10 cm
Processor mfr 5 cache
Storage mfr 512 Drive
Graphics mfr 770
Communications mfr 2 NIC
Nitrogen water vapor mfr 2570 ppm
Compressed air purity mfr 8573
Purge kit maximum pressure mfr 689 kpa
Purge gas flow rate mfr 15 LPM
Drain vessel minimum volume mfr 2 liters
Purge tubing dimensions mfr 6 ID
Magnet safe distance mfr 145 mm
Cell positions mfr eight eight
Samples plus reference mfr seven samples and a reference reference
Flow cell pump channels mfr three three
Nitrogen purge gas water vapor mfr 2570 ppm
Air purge gas quality mfr 8573
Minimum drain vessel volume mfr 2 liters
data acquisition rate mfr 250 second
wavelength drive speed mfr 2500 second
spectral bandwidth mfr 0.1...5 nm
G9862AA mfr 3500 Vis
G9866AA mfr 3500 Vis
G9867AA mfr 3500 Vis
Lamp module mfr 9864
Magnetic stirrer bar PTFE star type mfr 7418000400
Flow meter mfr 8003
Purge tubing mfr 3710043100
G9894A mfr Cary Compact Peltier UV-Vis Module Module
G9889A mfr Cary Multicell Peltier UV-Vis Module Module
Peltier side clearance mfr 20 cm
Peltier rear clearance mfr 10 cm
Non-Peltier side clearance mfr 10 cm
Non-Peltier rear clearance mfr 10 cm
Drain vessel minimum capacity mfr 2 liters
Drain outlet tubing OD mfr 6 OD
Dimensions, Weight & Mechanical Design
Workbench height mfr 90 cm
Drain tubing outer diameter mfr 6 OD
path length options mfr 2 cm
Electrical, Power & Drive Specifications
G9871A mfr 3500 A
G9873A mfr 3500 A
G9875A mfr 3500 A
Operating Conditions, Environment & Protection
Pollution degree mfr 61010
Cuvette cooling time mfr five minutes minutes
Standards, Safety & General Data
lamp replacement warranty mfr 10 year

Description

Architecture and series positioning

Behavior and measurement modes

Installation, connection and operation

Integration & Operating Notes

Cooling & Media
Peltier Multicell needs 15 LPM purge gas, not the Compact's 5 LPM

Multicell Peltier and Multizone Peltier systems require 15 LPM purge flow, three times the Compact Peltier figure, so the regulator and flow meter must be sized for that rate. Purging prevents condensation in the sample compartment at temperatures below ambient and keeps vapors and particles off optical surfaces.

User Manual, Compressed Gas Purging, page 27
Cooling & Media
Never connect purge gas directly to the module

Gas must pass through a pressure regulator; the G9891A purge kit is rated to a maximum of 689 kPa (100 PSIG). Use clean flexible plastic (PVC or equivalent) 6 mm OD/4 mm ID tubing, never rubber, because rubber tubing may be internally treated with talc that can be blown into the optical system. Nitrogen must have water vapor below 2570 ppm; compressed air must meet ISO 8573-1:2010 CLASS 1.3.1.

User Manual, Compressed Gas Purging, pages 26-27; Specifications, page 15
Mounting
Peltier Multicell needs 20 cm side and 10 cm rear clearance

Peltier models require 20 cm on both sides and about 10 cm at the rear for electrical and gas connections and for air flow; insufficient clearance impairs air-cooled Peltier control, especially at low temperatures. Non-Peltier models need 10 cm on both sides and 10 cm at the rear. Recommended ambient is 20 to 25 °C held within ±2 °C through the working day.

User Manual, Specifications, pages 12-13
Process Limits
Cuvettes stay hot after temperature reduction

The sample compartment and cuvettes may become extremely hot during Peltier operation and remain hot after the setpoint is lowered; allow at least five minutes to cool before removing cuvettes. Plan access to the eight positions around this cool-down so that multi-zone runs are not interrupted by handling hot cells.

User Manual, Introduction, page 21
Process Limits
Provide a 2-liter inert drain vessel for the Multicell module

Spills in the Multicell sample compartment drain through a 6 mm OD outlet into a user-supplied chemically inert collection vessel of at least 2 liters (4 pints); glass or narrow-necked vessels are not suitable. Check the tubing and vessel regularly for kinks, blockages or a full vessel, and select materials compatible with the solvents in use.

User Manual, Drain Outlet, page 27
Electrical
Each unit needs its own earth-grounded outlet

A 3-wire outlet grounded at the grounding pin must be provided, with a separate receptacle for each unit; extension cords and outlet adaptors are not recommended. The instrument is rated IEC 61010 measurement category I and must not be connected to measurement categories II, III or IV circuits. Disconnect mains before fuse replacement and use only the rating marked on the instrument.

User Manual, Specifications, page 14; Troubleshooting, Maintenance and Spare Parts, pages 29-30
Control & I/O
Control PC must match the Agilent-evaluated configuration

The controlling computer requires an Intel i5 3.0 GHz with 18 MB cache, 16 GB RAM, 512 GB SSD, Intel UHD Graphics 770 and Windows 10/11 Professional or Enterprise 64-bit. Agilent representatives install Workstation Plus or Networked Workstation software; the engine and module connect through the communications port, and the module front LED indicates status by color and flashing pattern.

User Manual, Specifications, page 14; Instrument Overview
Maintenance
Lamp module is the only user-serviceable cover

The lamp module operates at high voltage; switch off and disconnect the engine from mains before replacement, and never disassemble the module. All other screwed panels require Agilent service engineers. Troubleshooting and maintenance procedures are hosted in the Cary UV Help and Learning Center, and spare parts are ordered per the manual's spare-parts section.

User Manual, General Information and Safety Practices, page 7; Troubleshooting, Maintenance and Spare Parts

Selection & Integration Q&A

When should I choose the Multicell configuration rather than the Compact or Flexible Cary 3500 module?

Choose Multicell for eight cuvette stations (seven samples plus reference, or eight microcuvettes) and, in Peltier form, four zones each settable from -5 to 110 °C. The Compact module gives only two channels in one zone; the Flexible module is for large liquid and solid samples, not multi-station throughput.

What must be provided around a Peltier Multicell system for it to run correctly?

A regulated purge supply at 15 LPM (nitrogen below 2570 ppm water vapor, or ISO 8573-1:2010 CLASS 1.3.1 air) through the G9891A kit at no more than 689 kPa, 6 mm OD/4 mm ID plastic tubing, a 2-liter inert drain vessel, 20 cm side and 10 cm rear clearance, and a dedicated earth-grounded outlet per unit.

Can the instrument be installed and sited by our own lab staff?

Yes; the Cary system is designed to be completely customer-installable: install the software, install the engine and module hardware, then run System Health tests. Site it at 20 to 25 °C held within ±2 °C, observing the Peltier clearance of 20 cm at the sides and 10 cm at the rear, and follow the installation video and Help and Learning Center.

What maintenance and consumables fall outside the base delivery?

Users supply purge tubing and regulator, the 2-liter drain vessel and drain tubing, and the control PC meeting the i5/16 GB/512 GB specification. Fuse replacement is user-performed with the marked rating; lamp module replacement is the only other user-accessible service, and all further maintenance is directed to the Cary UV Help and Learning Center or Agilent engineers.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Cary 3500 UV-Vis Spectrophotometer
Brochure ·4,9 МБ ·16 pp.
View PDF
PDF
Cary Multicell Ambient and Peltier User's Guide
Manual ·34 pp.
View PDF