BINDER BF 400
BINDER BF 400 — Incubators with Temperature 5…100 °C.
The BINDER BF 400 is a 400 L forced-convection incubator with a stainless steel V2A (1.4301/AISI 304) interior and PID microprocessor control, operating from 5 °C above ambient to +100 °C. Within the BF series it is the mid-large 400 L modification, distinguished by a 0.85 kW single-phase 230 V supply and a 90 kg chamber load limit. It is intended for reproducible incubation and thermal conditioning of bulk laboratory samples in a temperature-controlled, fan-assisted air stream.
Direct drop-in replacements
BINDER BF Series — Model Comparison & Selection
Full specifications
| Temperature | 5...100 °C |
| Heating-up time to 100 °C | 12 min |
| Interior volume | 400 L |
| Load per rack | 35 kg |
| Nominal power | 0.85 kW |
| Permitted load | 90 kg (BF400-230V / BF400UL-120V) |
| Temperature fluctuation | 0.1 K |
| Temperature uniformity | 0.4 K |
| Back wall clearance | 160 mm (BF400-230V / BF400UL-120V) |
| Side wall clearance | 100 mm (BF400-230V / BF400UL-120V) |
| Article Number mfr | 9010 |
| Recovery time after door was opened for 30 s at 37°C mfr | 5 min |
| Depth | 765 mm (BF400-230V / BF400UL-120V) |
| Height | 1025 mm (BF400-230V / BF400UL-120V) |
| Interior width | 1000 mm (BF400-230V / BF400UL-120V) |
| Width | 1235 mm (BF400-230V / BF400UL-120V) |
| Net weight of the unit (empty) mfr | 145 kg |
| Power frequency | 50 Hz |
| Rated voltage | 230 V |
| Unit fuse | 12.5 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The BF 400 uses an APT.line preheating chamber system with fan-assisted forced-air circulation, an electronic PID controller with 0.1 °C display resolution, and a DIN 12880:2007 class 3.1 temperature safety device with visual and audible alarm.
- The interior, preheating chamber and inner door surfaces are stainless steel V2A (1.4301/AISI 304).
- Within the BF series, the BF 400 (400 L) sits between the BF 260 and BF 720; its lower temperature limit of +5 °C above ambient is the widest of the listed siblings (BF 56/260: +7 °C, BF 115: +8 °C, BF 720: +10 °C), making it the most flexible BF size for near-ambient work.
- Two electrical variants exist: BF400-230V (Art. 9010-0241, 230 V 1~ 50/60 Hz, CEE 7/7 plug) and BF400UL-120V (Art. 9010-0242, 120 V 1~ 60 Hz, NEMA 5-15 plug).
Thermal behavior
- Working range is +5 °C above ambient to +100 °C; nominal temperature is 100 °C at 0.85 kW nominal power and 3.7 A nominal current.
- Factory data give temperature fluctuation of 0.1 K and uniformity of 0.4 K, with a 12 min heating-up time to 100 °C and a 5 min recovery after a 30 s door opening at 37 °C.
- The chamber load is limited to 90 kg total and 35 kg per rack; the empty unit weighs 145 kg.
Installation, control and operation
- The unit requires 160 mm rear and 100 mm side wall clearance and must not be installed in unventilated recesses; it must be set up splash-proof and never in damp areas or puddles.
- Control is via the front-panel PID controller with ramp and timer functions, °C/°F selection, chamber addressing and interface mode; a serial RS 422 interface supports computer communication, e.g. APT-COM 4.
- The temperature safety device class 3.1 (DIN 12880:2007) cuts heating and displays an alarm value if tripped; air change is set with the ventilation slide.
Integration & Operating Notes
The chamber must not be installed in unventilated recesses. Prescribed minimum distances to walls and adjacent equipment are required so that heat from the 0.85 kW heating system can dissipate; otherwise the unit may overheat and the ambient-referenced lower temperature limit shifts.
Exceeding the 90 kg permitted load or the 35 kg per-rack limit can deform the racks and loading surfaces and disturb the forced-air circulation, invalidating the 0.4 K uniformity figure. Distribute samples evenly and account for the usable volume rather than the full 400 L interior.
The V2A (1.4301/AISI 304) interior is not resistant to corrosive ingredients such as acids and halides. Damage caused by such loading material is excluded from BINDER liability, so process media and spillage must be checked for compatibility before use.
Maintenance must be performed at least once a year by licensed electricians or experts authorized by BINDER, and annual repeat inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 is mandatory before initial startup and after any repair. Non-authorized servicing voids the warranty.
The door gasket must be replaced only in the cold state; fitting a gasket on a hot chamber can damage the seal and compromise temperature uniformity. After cleaning or disinfection, allow the chamber to dry thoroughly and aerate before restarting.
Transport and storage are permitted from -10 °C to +60 °C at max. 70 % r.H. non-condensing. After storage in a cold location, the chamber must stand at ambient for at least one hour until it is completely dry, preventing condensation-related electrical hazards on commissioning.
Selection & Integration Q&A
Pick the BF 400 for 400 L of usable volume with a +5 °C-above-ambient lower limit, the widest near-ambient range in the series. Choose the BF 260 for smaller loads or the BF 720 for larger batches, noting the BF 720's higher +10 °C lower limit.
The 230 V variant needs a grounded 230 V 1N~ 50/60 Hz supply with CEE 7/7 plug, sized for 3.7 A and 0.85 kW with 12.5 A unit fuse. The UL variant instead requires 115 V 1N~ 60 Hz via NEMA 5-15 receptacle.
Allow 160 mm at the rear and 100 mm at the sides, avoid unventilated recesses, and set up splash-proof away from damp areas or puddles. The lower temperature limit is ambient +5 °C, so room temperature directly sets the achievable minimum.
Annual maintenance by BINDER-authorized personnel and repeat electrical testing per EN 50678/VDE 0701 and EN 50699/VDE 0702 are required but not included. APT-COM 4 software, analog temperature output, additional Pt100 sensor, internal socket and audible alarm are options.