Elmo Rietschle 2BV5131
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV5131

Elmo Rietschle 2BV5131 — Liquid Ring Vacuum Pumps with Motor power 15 kW, Pumping speed 15 m³/h.

The 2BV5131 is a single-stage liquid-ring vacuum pump/compressor in the L-BV5 series, driven by a 15.0 kW motor and delivering 15.0 m³/h at 50 Hz or 17.4 m³/h at 60 Hz. It is the mid-range 15 kW modification, positioned between the 11 kW 2BV5121 and the high-capacity 2BV5161, and is intended for continuous vacuum or pressure duty where a robust liquid-ring principle is required.

Motor power
15 kW
Pumping speed
15 m³/h

Elmo Rietschle L-BV5 Series — Model Comparison & Selection

Model Motor power, kWOperating principleNoise level, dBPower supplyPumping speed, m³/hWeight, kg
2BV5131 Current 15Liquid ring74AC17.4178
2BV5110 5.5ring blow67AC—67
2BV5111 7.5Liquid ring723~ AC—124
2BV5121 11Liquid ring compressor70AC40—
2BV5161 15Liquid ring74AC500160
L-BV5 2060 ——————

Full specifications

Core Performance & Functional Specifications
Motor power 15.0 kW
Operating principle Liquid ring
Pumping speed 15.0 m³/h (50 Hz)
60 Hz: 17.4 m³/h
Dimensions, Weight & Mechanical Design
Number of stages 1 dimensionless
Weight 178 kg
Weight (alt var) mfr 182 kg
Electrical, Power & Drive Specifications
Power supply AC
Interfaces, Connections & Control
Inlet flange 190-210
Outlet flange 190-210
Operating Conditions, Environment & Protection
Noise level 74 dB(A)
Operating temperature 20 °C
Protection rating IP55
Sound pressure level (alt var) mfr 75 dB(A)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Mounting
Piping torque must not exceed 100 Nm

Over-tightening the suction or discharge connections can damage the pump casing or threaded ports. Use a torque wrench and verify that the mating flange or fitting is aligned without stress. The maximum permissible vibration velocity is 4.5 mm/s; ensure rigid mounting and flexible connections where necessary.

Operating Instructions — L-BV2, Installation, page 16
Process Limits
Gas temperature above 80 °C requires increased liquid flow

If the gas or vapour temperature exceeds +80 °C, the operating-liquid flow must be increased to 2× the design flow for 2BV5… types, or a pre-condenser must be installed upstream. Additionally, the suction pressure must remain at least 50 mbar above the vapour pressure of the operating liquid to avoid cavitation; consult the manufacturer if this cannot be guaranteed.

Operating Instructions — L-BV2, Technical data, page 10; ATEX supplement, Concerning 3.3
Electrical
Verify motor insulation resistance before commissioning

Measure the insulation resistance of the motor windings. If the value is ≤1 kΩ per volt of measurement potential, the windings must be dried before start-up. Also ensure that the supply voltage and frequency stay within ±5% and ±2% respectively, and that the minimum air gap of 5.5 mm between non-insulated live parts and earth is maintained in the terminal box.

Operating Instructions — L-BV2, Commissioning, page 20; Installation, page 19
Maintenance
Replace or re-grease bearings every 2 years or 18,000 hours

For ATEX versions, ball bearings must be serviced by a service technician every 2 years or 18,000 operating hours. Weekly dust removal from the unit is also required. Non-ATEX units have a bearing maintenance interval of 2.5 years or 20,000 operating hours. Use grease type UNIREX N3 or equivalent per DIN 51825-K3N, filling approximately 50% of the free space in the ball bearings.

Operating Instructions — L-BV2 ATEX, Concerning 9.1, page 8; Operating Instructions — L-BV2, Maintenance, page 28

Selection & Integration Q&A

When should I choose the 2BV5131 over the 2BV5121 or 2BV5161?

Choose the 2BV5131 when you need a 15 kW motor but a lower flow (15.0 m³/h at 50 Hz, 17.4 m³/h at 60 Hz) than the 2BV5121 (45 m³/h at 11 kW). It suits applications requiring higher pressure ratios or vacuum levels at modest flow, and is available in ATEX version for hazardous areas.

What are the requirements for the operating-liquid supply and monitoring?

The operating liquid (typically water) must be supplied at a temperature between +5 °C and +80 °C (nominal +15 °C) and at the design flow rate. For ATEX versions, the flow must be monitored and the unit must shut down if the flow drops to ≤50% of design. The liquid level must be kept within 140–185 mm (hf min/hf max for 2BV5131) and monitored independently.

Can I use a frequency converter with this pump?

For non-ATEX versions, a frequency converter may be used but the speed must not exceed 2066 min⁻¹ (range 1180–2066 min⁻¹). For ATEX versions, operation with a frequency converter is explicitly not permitted; the motor must be connected directly to the supply.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BV5 2BV5131 IE3 compressor (EN)
Datasheet ·428,6 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF