Elmo Rietschle 2BV2061
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV2061

Elmo Rietschle 2BV2061 — Liquid Ring Vacuum Pumps with Motor power 2.5 kW, Pumping speed 55.1 m³/h.

The 2BV2061 is a cast-iron liquid-ring vacuum pump/compressor in the L-BV2 series, driven by a 2.5 kW (50 Hz) / 3.0 kW (60 Hz) motor with IP55 protection. It delivers 27.0 m³/h at 50 Hz and 55.1 m³/h at 60 Hz, positioning it between the 2BV2060 and the larger 2BV2070/2071 in the series. Its primary purpose is continuous vacuum generation or low-pressure compression in systems where the operating liquid is supplied and controlled externally.

Motor power
2.5 kW
Pumping speed
55.1 m³/h

Elmo Rietschle L-BV2 Series — Model Comparison & Selection

Model Motor power, kWOperating principlePumping speed, m³/hNoise level, dBPower supplyWeight, kg
2BV2061 Current 3Liquid ring2765AC26
2BV2060 3.5Liquid ring vacuum pump—653~ 50/60 Hz28
2BV2070 7.3Liquid ring7070AC49
2BV2071 7.3Liquid ring50061AC64

Full specifications

Core Performance & Functional Specifications
Motor power 2.5 kW (50 Hz)
60 Hz: 3.0 kW
Operating principle Liquid ring
Pumping speed 27.0 m³/h (50 Hz)
60 Hz: 55.1 m³/h
Dimensions, Weight & Mechanical Design
Weight 26 kg (Cast iron)
Electrical, Power & Drive Specifications
Power supply AC (3~ 50/60 Hz)
Operating Conditions, Environment & Protection
Noise level 65 dB (50 Hz)
60 Hz: 70 dB
Protection rating IP55

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Mounting
Keep 34 mm clearance around fan guard for heat dissipation

The 2BV206. frame requires a minimum clearance of 34 mm around the fan guard to prevent overheating. Verify this dimension after installation, especially if the pump is mounted in a confined enclosure or close to walls.

Technical data, page 8
Process Limits
Operating liquid must stay between +5 °C and +80 °C

The operating-liquid temperature range is +5 °C to +80 °C with a nominal +15 °C. Exceeding these limits affects vacuum performance and may damage the liquid-ring internals. Ensure the supply and recirculation system can maintain this window under all load conditions.

Technical data, page 10
Process Limits
Do not exceed 1.1 bar abs discharge pressure in vacuum duty

In vacuum operation, the maximum discharge pressure is 1.1 bar abs when the design operating-liquid flow is maintained. Higher discharge pressures can overload the machine. Install appropriate pressure protection if the system can generate higher backpressures.

Technical data, page 10
Electrical
Maintain 5.5 mm air gap in terminal box wiring

At design voltage UN ≤ 690 V, the minimum air gap between non-insulated energized components and to earth is 5.5 mm. This clearance must be preserved when wiring the terminal box to avoid electrical breakdown and ensure safe operation.

Installation, page 19
Electrical
Verify motor insulation resistance before first start

Dry the windings if the insulation resistance is ≤1 kΩ per volt of measurement potential. Commissioning without this check risks motor failure. Measure insulation resistance before connecting power and after long shutdown periods.

Commissioning, page 20
Maintenance
Replace or re-grease bearings every 2.5 years or 20,000 hours

Bearing maintenance is due at 2.5 years or 20,000 operating hours, whichever comes first. Use UNIREX N3 grease (or DIN 51825-K3N equivalent), filling approximately 50% of the free space in roller bearings and 65% of adjacent areas. Do not mix grease types.

Maintenance, page 28
Process Limits
Fit intake strainer for first 100 operating hours

An intake strainer in the suction line is required for the first 100 operating hours to prevent installation residues from entering the pump. Remove or replace the strainer after this period to avoid unnecessary pressure drop.

Installation, page 16
Mounting
Do not exceed 100 Nm tightening torque on piping connections

Tightening torque for piping connections to suction and discharge must not exceed 100 Nm. Over-tightening can damage the cast-iron connections. Use a torque wrench and verify the limit during assembly.

Installation, page 16

Selection & Integration Q&A

When should I choose the 2BV2061 instead of the 2BV2060 or 2BV2070?

Choose the 2BV2061 when the duty point requires 27.0 m³/h at 50 Hz (55.1 m³/h at 60 Hz) and 2.5/3.0 kW motor power. The 2BV2060 offers lower flow at similar power; the 2BV2070/2071 provide higher flow and power but a larger frame. The 2BV2061 is the intermediate cast-iron option.

What are the requirements for the suction and discharge piping connected to the 2BV2061?

Piping connections must not be tightened beyond 100 Nm. Fit an intake strainer in the suction line for the first 100 operating hours. Ensure the discharge side can withstand 1.1 bar abs maximum in vacuum duty and install pressure protection if higher pressures are possible.

Can the 2BV2061 be installed outdoors or in a high-altitude location?

The standard 2BV2061 is rated for ambient temperatures +5 °C to +40 °C and installation altitudes up to 1000 m above sea level. For higher altitudes, consult the service department. The IP55 motor provides protection against dust and water jets, but additional enclosure may be needed for outdoor use.

What maintenance items and accessories are not included with the base pump?

The base delivery does not include the intake strainer (required for first 100 hours), operating liquid, grease (UNIREX N3 or equivalent), or frequency converter. Bearing maintenance at 2.5 years/20,000 hours requires service access. Optional ancillaries such as liquid separators and check valves must be ordered separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Technical Data Sheet — L-BV2 2BV2061 IE3 compressor (EN)
Datasheet ·382,8 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF