Elmo Rietschle 2BV2061
Elmo Rietschle 2BV2061 — Liquid Ring Vacuum Pumps with Motor power 2.5 kW, Pumping speed 55.1 m³/h.
The 2BV2061 is a cast-iron liquid-ring vacuum pump/compressor in the L-BV2 series, driven by a 2.5 kW (50 Hz) / 3.0 kW (60 Hz) motor with IP55 protection. It delivers 27.0 m³/h at 50 Hz and 55.1 m³/h at 60 Hz, positioning it between the 2BV2060 and the larger 2BV2070/2071 in the series. Its primary purpose is continuous vacuum generation or low-pressure compression in systems where the operating liquid is supplied and controlled externally.
Elmo Rietschle L-BV2 Series — Model Comparison & Selection
Full specifications
| Motor power | 2.5 kW (50 Hz) 60 Hz: 3.0 kW |
| Operating principle | Liquid ring |
| Pumping speed | 27.0 m³/h (50 Hz) 60 Hz: 55.1 m³/h |
| Weight | 26 kg (Cast iron) |
| Power supply | AC (3~ 50/60 Hz) |
| Noise level | 65 dB (50 Hz) 60 Hz: 70 dB |
| Protection rating | IP55 |
Description
Construction and series positioning
- The 2BV2061 is a single-stage liquid-ring machine with a cast-iron casing and a directly coupled AC motor (3~ 50/60 Hz).
- Within the L-BV2 series, it sits above the 2BV2060 (same nominal power class but lower pumping speed) and below the 2BV2070/2071, which offer higher motor power and pumping speed. The 2BV2061 is the intermediate choice when the duty point requires more flow than the 2BV2060 but does not justify the larger frame of the 2BV2070.
- Unlike the 2BV2070/2071 and 2BV5.. types, the 2BV2061 is not available in the higher corrosion-resistance/hygiene construction; it is supplied in cast iron only.
Behavior under load and media
- Performance scales with frequency: 27.0 m³/h at 50 Hz and 55.1 m³/h at 60 Hz, with motor power rising from 2.5 kW to 3.0 kW accordingly. Noise level is 65 dB at 50 Hz and 70 dB at 60 Hz.
- The machine is designed for gas/vapour temperatures up to +80 °C and an operating-liquid temperature range of +5 °C to +80 °C (nominal +15 °C). Ambient temperature must remain between +5 °C and +40 °C.
- Maximum discharge pressure in vacuum operation is 1.1 bar abs; maximum permissible internal pressure is 8 bar abs. The first fill quantity of operating liquid is 0.5 L for the 2BV206. frame.
- Maximum water carry-over through the inlet is 2.5× the design operating-liquid flow continuously, or 7× for a maximum of 2 s.
Installation, connection and control
- The motor is connected in the terminal box; a minimum air gap of 5.5 mm between non-insulated energized components and to earth must be maintained at design voltage UN ≤ 690 V. Supply tolerance is ±5% voltage and ±2% frequency.
- Piping connections to suction and discharge must not be tightened beyond 100 Nm. An intake strainer should be fitted in the suction line for the first 100 operating hours.
- Minimum clearance for heat dissipation around the fan guard is 34 mm for the 2BV206. frame. Maximum installation altitude is 1000 m above sea level; consult the service department above this value.
- When operated with a frequency converter, the maximum speed for the 2BV2060/2061 is 2636–4612 min⁻¹. The ATEX supplement explicitly forbids frequency-converter operation for ATEX variants, but the standard 2BV2061 permits it within this speed window.
- Bearing maintenance is required every 2.5 years or 20,000 operating hours; grease type UNIREX N3 (or DIN 51825-K3N equivalent) is used, filling approximately 50% of the free space in roller bearings and 65% of adjacent areas.
Integration & Operating Notes
The 2BV206. frame requires a minimum clearance of 34 mm around the fan guard to prevent overheating. Verify this dimension after installation, especially if the pump is mounted in a confined enclosure or close to walls.
The operating-liquid temperature range is +5 °C to +80 °C with a nominal +15 °C. Exceeding these limits affects vacuum performance and may damage the liquid-ring internals. Ensure the supply and recirculation system can maintain this window under all load conditions.
In vacuum operation, the maximum discharge pressure is 1.1 bar abs when the design operating-liquid flow is maintained. Higher discharge pressures can overload the machine. Install appropriate pressure protection if the system can generate higher backpressures.
At design voltage UN ≤ 690 V, the minimum air gap between non-insulated energized components and to earth is 5.5 mm. This clearance must be preserved when wiring the terminal box to avoid electrical breakdown and ensure safe operation.
Dry the windings if the insulation resistance is ≤1 kΩ per volt of measurement potential. Commissioning without this check risks motor failure. Measure insulation resistance before connecting power and after long shutdown periods.
Bearing maintenance is due at 2.5 years or 20,000 operating hours, whichever comes first. Use UNIREX N3 grease (or DIN 51825-K3N equivalent), filling approximately 50% of the free space in roller bearings and 65% of adjacent areas. Do not mix grease types.
An intake strainer in the suction line is required for the first 100 operating hours to prevent installation residues from entering the pump. Remove or replace the strainer after this period to avoid unnecessary pressure drop.
Tightening torque for piping connections to suction and discharge must not exceed 100 Nm. Over-tightening can damage the cast-iron connections. Use a torque wrench and verify the limit during assembly.
Selection & Integration Q&A
Choose the 2BV2061 when the duty point requires 27.0 m³/h at 50 Hz (55.1 m³/h at 60 Hz) and 2.5/3.0 kW motor power. The 2BV2060 offers lower flow at similar power; the 2BV2070/2071 provide higher flow and power but a larger frame. The 2BV2061 is the intermediate cast-iron option.
Piping connections must not be tightened beyond 100 Nm. Fit an intake strainer in the suction line for the first 100 operating hours. Ensure the discharge side can withstand 1.1 bar abs maximum in vacuum duty and install pressure protection if higher pressures are possible.
The standard 2BV2061 is rated for ambient temperatures +5 °C to +40 °C and installation altitudes up to 1000 m above sea level. For higher altitudes, consult the service department. The IP55 motor provides protection against dust and water jets, but additional enclosure may be needed for outdoor use.
The base delivery does not include the intake strainer (required for first 100 hours), operating liquid, grease (UNIREX N3 or equivalent), or frequency converter. Bearing maintenance at 2.5 years/20,000 hours requires service access. Optional ancillaries such as liquid separators and check valves must be ordered separately.