Elmo Rietschle 2BV5121
Elmo Rietschle 2BV5121 — Liquid Ring Vacuum Pumps with Motor power 11 kW, Pumping speed 40 m³/h.
The 2BV5121 is a liquid-ring compressor in the L-BV5 series, built with a cast-iron casing and bronze or CrNi steel impeller, available in IE3 efficiency. It delivers 40 m³/h at 50 Hz and 45 m³/h at 60 Hz with an 11 kW motor, positioning it between the 7.5 kW 2BV5111 and the 15 kW 2BV5131. It is used for handling gases and vapours in vacuum or compressor duty where a liquid ring provides robust, oil-free operation.
Elmo Rietschle L-BV5 Series — Model Comparison & Selection
| Model | Motor power, kW | Operating principle | Noise level, dB | Power supply | Pumping speed, m³/h | Weight, kg |
|---|---|---|---|---|---|---|
| 2BV5121 Current | 11 | Liquid ring compressor | 70 | AC | 40 | — |
| 2BV5110 | 5.5 | ring blow | 67 | AC | — | 67 |
| 2BV5111 | 7.5 | Liquid ring | 72 | 3~ AC | — | 124 |
| 2BV5131 | 15 | Liquid ring | 74 | AC | 17.4 | 178 |
| 2BV5161 | 15 | Liquid ring | 74 | AC | 500 | 160 |
| L-BV5 2060 | — | — | — | — | — | — |
Full specifications
| Motor power | 11.0 kW (50 Hz) 60 Hz: 11.0 kW |
| Operating principle | Liquid ring compressor |
| Pumping speed | 40.0 m³/h (50 Hz) 60 Hz: 45.0 m³/h |
| Power supply | AC (3~ 50/60 Hz) |
| Noise level | 70 dB(A) (50 Hz) 60 Hz: 75 dB(A) |
| Protection rating | IP55 |
Description
Construction and series positioning
- The 2BV5121 is a liquid-ring compressor (operating principle: liquid ring compressor) within the L-BV5 series. It uses a cast-iron casing with either a bronze impeller (material code K) or a CrNi steel impeller (code C); a fully CrNi steel construction (code H) is also available. This modification is distinguished from its siblings by its 11 kW motor and mid-range pumping speed: the 2BV5110 (5.5 kW, ring blow) and 2BV5111 (7.5 kW) are smaller, while the 2BV5131 (15 kW) and 2BV5161 (15 kW, 575 m³/h) are larger or differently optimized. The 2BV5121 thus fills the gap for duties requiring around 40–45 m³/h at 50/60 Hz.
- The motor is rated 11.0 kW at both 50 and 60 Hz, with a 3-phase AC supply (3~ 50/60 Hz) and IP55 protection. Noise levels are 70 dB(A) at 50 Hz and 75 dB(A) at 60 Hz. The unit is available in IE3 or NP efficiency versions, and ATEX category 2G variants exist (see ATEX supplement).
Behavior under load and media
- As a liquid-ring machine, performance depends on the operating liquid (normally water) forming the sealing ring. The base manual specifies a maximum gas/vapour temperature of +80 °C; for higher temperatures, the operating-liquid flow must be increased to 2.5× (2BV2…) or 2× (2BV5…) the design flow, or a pre-condenser installed. The operating-liquid temperature range is +5 °C to +80 °C (nominal +15 °C), and ambient temperature must stay within +5 °C to +40 °C.
- Maximum discharge pressure in vacuum operation is 1.3 bar abs for 2BV5… types, and maximum permissible internal pressure is 8 bar abs (6 bar abs for 2BV5410-.F). The first fill quantity of operating liquid for the 2BV5121 is 3.0 L. Maximum operating-liquid carry-over through the inlet is 2.5× design flow continuous and 5× for max 2 s (for 2BV51.. types).
- When driven by a frequency converter, the maximum speed for the 2BV5121 is 1290–2258 min⁻¹; do not exceed this range.
Installation, connection and operation
- Installation requires maintaining minimum clearances for heat dissipation: 53 mm for the 2BV5121 (fan guard clearance). The maximum installation altitude is 1000 m above sea level; consult the service department if higher. Piping connections to suction and discharge must not be tightened beyond 100 Nm. An intake strainer should be fitted in the suction line for the first 100 operating hours.
- Electrical connection must respect a supply tolerance of ±5% voltage and ±2% frequency deviation. Minimum air gap between non-insulated energized components and earth is 5.5 mm at design voltage UN ≤ 690 V. Motor insulation resistance must be checked before commissioning; dry windings if ≤1 kΩ per volt of measurement potential. Cable glands must be tightened to the specified torques (e.g., M12x1.5: 4–6 Nm).
- For ATEX variants, additional monitoring is mandatory: pressure monitoring on the discharge side (G2) must switch off the unit if maximum discharge pressure is exceeded; operating-liquid feed monitoring must trip at ≤50% of design flow; liquid level monitoring must only permit start-up when the level is between 130 mm and 170 mm (hf min/hf max for 2BV5121). Operating-liquid temperature monitoring must shut down at ≥60 °C. Bleeder resistance to ground must be <10⁶ Ω for the unit and each accessory. Frequency converter operation is not permitted for ATEX versions.
Integration & Operating Notes
Insufficient clearance will cause overheating and reduced motor life. The 2BV5121 requires at least 53 mm free space around the fan guard for heat dissipation, as specified in the technical data. Ensure the installation location allows unobstructed airflow and does not exceed the maximum ambient temperature of +40 °C.
The maximum permissible gas/vapour temperature is +80 °C. For higher temperatures, increase the operating-liquid flow to 2× the design flow for 2BV5… types or install a pre-condenser. Also provide guards against burns if surface temperatures exceed safe limits. Exceeding this limit without mitigation can damage the liquid ring and seals.
Measure insulation resistance of the motor windings. If the resistance is ≤1 kΩ per volt of measurement potential, dry the windings before connecting power. Failure to do so may result in motor failure due to moisture ingress during storage or installation. This check is mandatory per the commissioning section.
For ATEX variants, monitoring systems for operating-liquid feed and liquid level must be fully functional independently of each other, even when using computer-programmed controls. The liquid level monitoring must only permit start-up when the level is between 130 mm and 170 mm (hf min/hf max for 2BV5121). Flow monitoring must trip at ≤50% of design flow. Design for independence per EN ISO 13849.
Ball bearings must be serviced by a service technician every 2 years or 18,000 operating hours, whichever comes first. Use grease type UNIREX N3 (ESSO) or equivalent per DIN 51825-K3N, filling approximately 50% of the free space in ball bearings and 65% of adjacent areas. For ATEX units, weekly dust removal is also required. Operator may not perform dismantling work.
When connecting suction and discharge piping, the tightening torque must not exceed 100 Nm. Over-tightening can crack the casing or damage the threaded connections, leading to leaks and potential safety hazards. Use appropriate gaskets and ensure proper alignment to avoid stress on the ports.
Selection & Integration Q&A
Choose the 2BV5121 when you need ~40–45 m³/h at 50/60 Hz with an 11 kW motor. The 2BV5111 offers only 7.5 kW and lower flow, while the 2BV5131 has 15 kW and is a larger or differently optimized unit. The 2BV5121 balances flow and power for medium-duty vacuum or compressor applications.
The operating liquid (typically water) must be supplied at a temperature between +5 °C and +80 °C (nominal +15 °C) and at the design flow rate. For the 2BV5121, the first fill quantity is 3.0 L. If the gas/vapour temperature exceeds 80 °C, increase the operating-liquid flow to 2× the design flow. Ensure the liquid is free of particles that could clog the ring; a strainer is recommended for the first 100 hours.
The standard 2BV5121 is rated for ambient temperatures of +5 °C to +40 °C and installation altitudes up to 1000 m above sea level. For outdoor installation, provide protection against weather and ensure the IP55 motor is not submerged. For altitudes above 1000 m, consult the manufacturer for derating. ATEX variants have additional restrictions on ambient and operating-liquid temperatures.
The base delivery does not include the operating-liquid supply system, suction strainer (required for first 100 hours), or monitoring sensors for ATEX operation. You must provide a liquid separator, flow monitor, pressure switch, and liquid level sensor if required. Bearings need re-greasing every 2 years or 18,000 hours with UNIREX N3 grease. For ATEX, bleeder resistors and certified sensors are mandatory.