Elmo Rietschle C-VLR 301
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle C-VLR 301

Elmo Rietschle C-VLR 301 — Claw Vacuum Pumps with Motor power 5.5 kW, Pumping speed 350 m³/h, Ultimate pressure 150 mbar.

The C-VLR 301 is a double-shaft, contact-free rotary claw vacuum pump with dry-running rotors synchronized by an oil-lubricated gear pair, available in standard CD and corrosion-protective XD design. It delivers 290 m³/h at 50 Hz (350 m³/h at 60 Hz) and reaches an ultimate pressure of 150 mbar, with continuous operation permitted between 700 and 150 mbar (abs.). Its 5.5 kW (50 Hz) / 6.5 kW (60 Hz) motor and non-contact claw principle suit continuous dry vacuum duty in non-aggressive gas and vapor systems.

Motor power
5.5 kW
Pumping speed
350 m³/h
Ultimate pressure
150 mbar

Elmo Rietschle C-VLR Series — Model Comparison & Selection

Model Operating principleNoise level, dBWeight, kgMotor power, kWPumping speed, m³/hUltimate pressure, mbar
C-VLR 301 Current claw742855.5290150
C-VLR 1000 claw8275718.5950200
C-VLR 150 Claw—————
C-VLR 401 contact free running cla79470———
C-VLR 60 —7847———
C-VLR 62 ——————

Full specifications

Core Performance & Functional Specifications
Motor power 5.5 kW
50 Hz: 5.5 kW · 60 Hz: 6.5 kW
Operating principle claw
Pumping speed 290 m³/h
50 Hz: 290 m³/h · 60 Hz: 350 m³/h
Ultimate pressure 150 mbar
Rotational speed 2900 rpm
50 Hz: 2900 min-1 · 60 Hz: 3500 min-1
Operating principle (alt var) mfr Claw
Dimensions, Weight & Mechanical Design
Weight 285 kg
Electrical, Power & Drive Specifications
Power supply 400 / 690 V ± 10% (50 Hz)
60 Hz: 220 / 380 V ± 10%
Materials, Media & Process Compatibility
Oil capacity 1.5 l
Operating Conditions, Environment & Protection
Noise level 74 dB
50 Hz: 74 dB(A) · 60 Hz: 77 dB(A)

Description

Construction and series positioning

Behavior and operating envelope

Installation, connection and control

Specifications (frequency-dependent)

Integration & Operating Notes

Process Limits
Keep exhaust back pressure below +50 mbar

The maximum permissible back pressure is +50 mbar. Any restriction or blockage in the exhaust line raises pressure beyond this limit and can overload the pump; if the process requires higher back pressure, consult the manufacturer before installation.

Operating Instructions BA 885-EN, Sections 2.4 and 5.3
Process Limits
Closed-system volume must stay under 2% of nominal capacity

When evacuating a closed system, the volume to be evacuated must be no more than 2% of the nominal pumping capacity. Larger volumes extend evacuation time and can overload the pump, so size the evacuated volume against the 290 m³/h (50 Hz) nominal capacity.

Operating Instructions BA 885-EN, Section 4.4
Mounting
Mount horizontally within 8° and secure against tipping

The machine may only be operated when set up horizontally with a maximum inclination of 8° in all directions. Mount it on a plane, even floor and secure it against tipping and falling; operation outside this orientation risks inadequate lubrication and mechanical damage.

Operating Instructions BA 885-EN, Section 5.2
Cooling & Media
Respect 30 cm wall clearance and prevent hot-air recirculation

Cooling air inlets and outlets must be at least 30 cm from adjacent walls, and the hot cooling air leaving the machine must not be drawn in again. Recirculation or blocked clearances cause overheating; ambient and inlet temperature must also remain between 5 °C and 40 °C.

Operating Instructions BA 885-EN, Sections 5.2 and 2.4
Electrical
Verify counter-clockwise rotation before coupling the process

The motor must rotate counter-clockwise when viewed at the motor blower; check with a phase sequence indicator. A brief start for this check must not exceed two seconds, because wrong rotation direction can damage the machine and cause injury.

Operating Instructions BA 885-EN, Section 6.1.2
Electrical
Select a motor protection switch with delayed short-circuit trip

The motor protection switch must have an overload-dependent turn-off delay that accounts for short excess current at start-up, per VDE 0660 Part 102 or IEC 60947-4-1. A switch without this delay will nuisance-trip during cold starts; supply voltage deviation must also stay within ±5 % and frequency within ±2 %.

Operating Instructions BA 885-EN, Sections 8 and 5.5
Maintenance
Run dry-air purge before shutdowns longer than 2 hours

Before shutdown for more than 2 hours or decommissioning, run the pump at 700 mbar (abs.) with dry air for at least 15–30 minutes. This removes moisture and pollution that would otherwise deposit on rotors and casing and could prevent restart.

Operating Instructions BA 885-EN, Section 6.2.1
Maintenance
Never restart after automatic shut-off without finding the cause

The error table covers motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating and strange noise. After an automatic shut-off, the cause must be found and remedied before restart; also disconnect power and secure against restart, and allow the machine to cool before maintenance.

Operating Instructions BA 885-EN, Section 7 Errors
Maintenance
Maintain oil level at middle of sight glass

The oil level must be filled to the middle of the oil sight glass and topped up at the oil fill

Operating Instructions BA 885-EN, Section 6.2

Selection & Integration Q&A

When should I choose the C-VLR 301 instead of the C-VLR 401 or C-VLR 1000?

Pick the C-VLR 301 for 290 m³/h at 50 Hz and 150 mbar ultimate pressure with a 5.5 kW motor. The C-VLR 1000 is a much larger 18.5 kW, 950 m³/h, 200 mbar machine; the C-VLR 401 is the next size up in the same series.

What motor protection and supply conditions must the electrical panel provide for this pump?

Use a motor protection switch with overload-dependent delayed trip per VDE 0660 Part 102 / IEC 60947-4-1 to ride through start-up current. Supply must be within ±5 % voltage and ±2 % frequency of the motor data plate; installation per EN 60204 by a qualified electrician.

What ambient and duty-cycle limits apply when installing the C-VLR 301 in a plant room?

Ambient and inlet temperature 5–40 °C, horizontal mounting within 8° inclination, 30 cm wall clearance for cooling air without hot-air recirculation, and 50 cm maintenance space. Above 1000 m altitude output drops; frequent switching ~10 times/h needs manufacturer consultation.

What maintenance and consumables are needed, and what is not included in base delivery?

Plan for gearbox oil (1.5 l capacity, level to middle of sight glass), air filter and mesh filter service, and motor/coupling checks; intervals depend on operating time, conditions and oil type. Spare parts are ordered per list E885 using the nameplate serial number.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — C-VLR 301 vacuum pump (BA 885-EN, ed. 1.2 11.04.2021, EN)
Manual ·1,6 МБ ·34 pp.
View PDF
PDF
Technical Data Sheet — C-VLR 301 IE3 vacuum pump DE/EN)
Datasheet ·438,0 КБ ·4 pp.
View PDF
PDF
Spare Parts List — C-VLR 301 (E885, ed. 2.0 16.02.2023, EN)
Spare parts ·635,0 КБ ·4 pp.
View PDF