Elmo Rietschle C-VLR 301
Elmo Rietschle C-VLR 301 — Claw Vacuum Pumps with Motor power 5.5 kW, Pumping speed 350 m³/h, Ultimate pressure 150 mbar.
The C-VLR 301 is a double-shaft, contact-free rotary claw vacuum pump with dry-running rotors synchronized by an oil-lubricated gear pair, available in standard CD and corrosion-protective XD design. It delivers 290 m³/h at 50 Hz (350 m³/h at 60 Hz) and reaches an ultimate pressure of 150 mbar, with continuous operation permitted between 700 and 150 mbar (abs.). Its 5.5 kW (50 Hz) / 6.5 kW (60 Hz) motor and non-contact claw principle suit continuous dry vacuum duty in non-aggressive gas and vapor systems.
Elmo Rietschle C-VLR Series — Model Comparison & Selection
| Model | Operating principle | Noise level, dB | Weight, kg | Motor power, kW | Pumping speed, m³/h | Ultimate pressure, mbar |
|---|---|---|---|---|---|---|
| C-VLR 301 Current | claw | 74 | 285 | 5.5 | 290 | 150 |
| C-VLR 1000 | claw | 82 | 757 | 18.5 | 950 | 200 |
| C-VLR 150 | Claw | — | — | — | — | — |
| C-VLR 401 | contact free running cla | 79 | 470 | — | — | — |
| C-VLR 60 | — | 78 | 47 | — | — | — |
| C-VLR 62 | — | — | — | — | — | — |
Full specifications
| Motor power | 5.5 kW 50 Hz: 5.5 kW · 60 Hz: 6.5 kW |
| Operating principle | claw |
| Pumping speed | 290 m³/h 50 Hz: 290 m³/h · 60 Hz: 350 m³/h |
| Ultimate pressure | 150 mbar |
| Rotational speed | 2900 rpm 50 Hz: 2900 min-1 · 60 Hz: 3500 min-1 |
| Operating principle (alt var) mfr | Claw |
| Weight | 285 kg |
| Power supply | 400 / 690 V ± 10% (50 Hz) 60 Hz: 220 / 380 V ± 10% |
| Oil capacity | 1.5 l |
| Noise level | 74 dB 50 Hz: 74 dB(A) · 60 Hz: 77 dB(A) |
Description
Construction and series positioning
- The C-VLR 301 uses two contact-free rotary claws synchronized by an oil-lubricated gear pair; the gearbox and compression chamber are separated by special seals, so the pumping chamber runs dry.
- An integral non-return valve and vacuum relief valve are built in; cooling is by a drum fan drawing fresh air between compressor and insulation hood.
- Within the C-VLR series, this model sits between the smaller C-VLR 150 and the larger C-VLR 401/501 and C-VLR 1000. Unlike the C-VLR 1000 (18.5 kW, 950 m³/h, 200 mbar), the C-VLR 301 is a 5.5 kW (50 Hz) / 6.5 kW (60 Hz), 290 m³/h (50 Hz) / 350 m³/h (60 Hz) machine reaching 150 mbar.
- Two designs exist: CD (standard) for non-explosive, non-combustible, non-aggressive, non-poisonous dry gases and gas-air mixtures, and XD (corrosion-protective coating) for damp gases and water vapour.
Behavior and operating envelope
- Continuous operation is permitted at any inlet pressure between 700 mbar (abs.) and 150 mbar (abs.); pumping capacity with unrestricted suction is 290 m³/h at 50 Hz and 350 m³/h at 60 Hz.
- Maximum permissible back pressure is +50 mbar; the exhaust line must not be restricted or blocked.
- Ambient and inlet temperature must stay between 5 °C and 40 °C. Frequent switching at roughly 10 times per hour or more, or high ambient/inlet temperatures, may exceed the excess-temperature limit of motor winding and bearings and requires manufacturer consultation.
- Output reduction is noticeable above 1000 m above sea level.
Installation, connection and control
- The machine must be set up horizontally with max. 8° inclination in all directions, secured against tipping, with at least 50 cm maintenance space and 30 cm clearance from walls for cooling air; hot exhaust air must not be recirculated.
- Electrical installation per EN 60204 by a qualified electrician with a motor protection switch; motors comply with DIN EN 60034, IP 55, insulation class F. Permissible voltage deviation is ±5 % and frequency deviation ±2 %.
- Before commissioning, check rotation direction: the motor must turn counter-clockwise viewed at the motor blower; a brief start for this check must not exceed two seconds.
- Before shutdown for more than 2 hours, run the pump at 700 mbar (abs.) with dry air for 15–30 minutes to remove moisture and pollution.
Specifications (frequency-dependent)
- Motor power: 5.5 kW at 50 Hz; 6.5 kW at 60 Hz.
- Pumping speed: 290 m³/h at 50 Hz; 350 m³/h at 60 Hz.
- Noise level: 74 dB(A) at 50 Hz; 77 dB(A) at 60 Hz.
- Rotational speed: 2900 min⁻¹ at 50 Hz; 3500 min⁻¹ at 60 Hz.
- Power supply: 400 / 690 V ± 10% at 50 Hz; 220 / 380 V ± 10% at 60 Hz. Note: the ±10% tolerance is the motor nameplate tolerance; the permissible supply deviation for operation is ±5% as stated in the Electrical note.
Integration & Operating Notes
The maximum permissible back pressure is +50 mbar. Any restriction or blockage in the exhaust line raises pressure beyond this limit and can overload the pump; if the process requires higher back pressure, consult the manufacturer before installation.
When evacuating a closed system, the volume to be evacuated must be no more than 2% of the nominal pumping capacity. Larger volumes extend evacuation time and can overload the pump, so size the evacuated volume against the 290 m³/h (50 Hz) nominal capacity.
The machine may only be operated when set up horizontally with a maximum inclination of 8° in all directions. Mount it on a plane, even floor and secure it against tipping and falling; operation outside this orientation risks inadequate lubrication and mechanical damage.
Cooling air inlets and outlets must be at least 30 cm from adjacent walls, and the hot cooling air leaving the machine must not be drawn in again. Recirculation or blocked clearances cause overheating; ambient and inlet temperature must also remain between 5 °C and 40 °C.
The motor must rotate counter-clockwise when viewed at the motor blower; check with a phase sequence indicator. A brief start for this check must not exceed two seconds, because wrong rotation direction can damage the machine and cause injury.
The motor protection switch must have an overload-dependent turn-off delay that accounts for short excess current at start-up, per VDE 0660 Part 102 or IEC 60947-4-1. A switch without this delay will nuisance-trip during cold starts; supply voltage deviation must also stay within ±5 % and frequency within ±2 %.
Before shutdown for more than 2 hours or decommissioning, run the pump at 700 mbar (abs.) with dry air for at least 15–30 minutes. This removes moisture and pollution that would otherwise deposit on rotors and casing and could prevent restart.
The error table covers motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating and strange noise. After an automatic shut-off, the cause must be found and remedied before restart; also disconnect power and secure against restart, and allow the machine to cool before maintenance.
The oil level must be filled to the middle of the oil sight glass and topped up at the oil fill
Selection & Integration Q&A
Pick the C-VLR 301 for 290 m³/h at 50 Hz and 150 mbar ultimate pressure with a 5.5 kW motor. The C-VLR 1000 is a much larger 18.5 kW, 950 m³/h, 200 mbar machine; the C-VLR 401 is the next size up in the same series.
Use a motor protection switch with overload-dependent delayed trip per VDE 0660 Part 102 / IEC 60947-4-1 to ride through start-up current. Supply must be within ±5 % voltage and ±2 % frequency of the motor data plate; installation per EN 60204 by a qualified electrician.
Ambient and inlet temperature 5–40 °C, horizontal mounting within 8° inclination, 30 cm wall clearance for cooling air without hot-air recirculation, and 50 cm maintenance space. Above 1000 m altitude output drops; frequent switching ~10 times/h needs manufacturer consultation.
Plan for gearbox oil (1.5 l capacity, level to middle of sight glass), air filter and mesh filter service, and motor/coupling checks; intervals depend on operating time, conditions and oil type. Spare parts are ordered per list E885 using the nameplate serial number.