Elmo Rietschle C-VLR 401
Elmo Rietschle C-VLR 401 — Claw Vacuum Pumps.
The C-VLR 401 is a contact-free running claw vacuum pump with a double-shaft dry rotary piston design, gearbox oil lubrication, and an integral frequency converter for infinitely variable speed. It delivers 380 m³/h at 50 Hz free intake and operates continuously between 700 mbar (abs.) and 200 mbar (abs.) inlet pressure, distinguishing it from smaller siblings like the C-VLR 301 (290 m³/h) and larger C-VLR 501 (495 m³/h). It is intended for dry, non-aggressive gas evacuation in industrial vacuum systems where oil-free compression and variable speed control are required.
Elmo Rietschle C-VLR Series — Model Comparison & Selection
| Model | Operating principle | Noise level, dB | Weight, kg | Motor power, kW | Pumping speed, m³/h | Ultimate pressure, mbar |
|---|---|---|---|---|---|---|
| C-VLR 401 Current | contact free running cla | 79 | 470 | — | — | — |
| C-VLR 1000 | claw | 82 | 757 | 18.5 | 950 | 200 |
| C-VLR 150 | Claw | — | — | — | — | — |
| C-VLR 301 | claw | 74 | 285 | 5.5 | 290 | 150 |
| C-VLR 60 | — | 78 | 47 | — | — | — |
| C-VLR 62 | — | — | — | — | — | — |
Full specifications
| Operating principle | contact free running claw vacuum pump |
| Condensate drain silencer mfr | G 1⁄2 |
| Height | 963 mm |
| Length | 1169 mm |
| Weight | 470 kg |
| Width | 598 mm |
| Inlet flange | G 3 |
| Outlet flange | G 3 |
| Oil capacity | 1.75 l |
| Noise level | 79 dB 50 Hz: 79 dB · 60 Hz: 82 dB |
| Sound pressure level (max.) 60 Hz (alt var) mfr | 82 dB |
Description
Construction and series positioning
- Double-shaft dry claw rotary piston pump with non-contacting rotors synchronised by an oil-lubricated gear pair; compression chamber separated from gearbox by special seals.
- Integral frequency converter (VSD) enables infinitely variable speed; standard version handles dry gases, while the XD variant adds corrosion-protective coating and condensate drain for water-moist gases.
- Within the C-VLR series, the 401 sits between the C-VLR 301 (290 m³/h, 5.5 kW) and C-VLR 501 (495 m³/h); it shares the 470 kg weight class and G 3 connections with the 501 but offers lower capacity for medium-duty applications.
Behavior under load and media
- Continuous operation is permitted at any inlet pressure between 700 mbar (abs.) and 200 mbar (abs.); operation outside this range may be outside designated use.
- Free intake pumping capacity is 380 m³/h at 50 Hz; for closed-system evacuation, the volume must not exceed 2% of nominal pumping capacity to avoid overload.
- Increased switching frequency (≈10 times per hour) or elevated ambient/suction temperatures can exceed motor winding and bearing temperature limits; consult manufacturer for such duty.
- The XD variant is suitable for water-damp gases (water vapour) and requires regular condensate discharge from the silencer.
Installation, connection, and control
- Machine must be installed horizontally with max. 8° inclination in all directions; provide at least 50 cm maintenance space and 30 cm clearance for cooling air.
- Electrical connection by qualified electrician per EN 60204; user must provide main switch and motor protection switch. Direct-on-line starting is not permitted for motors above 5.2 kVA (three-phase) or with starting current >60 A; use star-delta, soft starter, or frequency inverter.
- Integral non-return valve prevents ventilation of evacuated system after pump stops and may not be removed. Exhaust line must not be restricted; max. back pressure +50 mbar.
- For VSD version, frequency converter input is 3 AC 400 V –15% to 480 V +10%, 47–63 Hz, TN/TT networks; IP 65 protection requires suitable cable glands.
Integration & Operating Notes
Operating outside this inlet pressure band may be considered outside designated use and can lead to overheating or mechanical damage. Ensure process control keeps the pump within this range during all phases, including start-up and shutdown.
When evacuating a closed system, the volume to be evacuated must be no more than 2% of the pump's nominal suction capacity (380 m³/h at 50 Hz). Larger volumes can cause excessive evacuation times or pump overload; size reservoirs or connected volumes accordingly.
The machine must be set up on a level, straight foundation able to take its weight (470 kg). Inclination beyond 8° can impair lubrication and cause premature wear. Secure against tipping and falling, and provide at least 50 cm maintenance space and 30 cm clearance for cooling air.
The motor fan must rotate counter-clockwise when viewed from the fan. Use a phase sequence indicator to verify the clockwise rotating field and perform a brief start (max. 2 seconds). Wrong rotation direction can damage the machine and cause injury.
For three-phase motors with apparent power above 5.2 kVA or starting current above 60 A, direct-on-line starting is not permitted. Use star-delta starter, soft starter, or frequency inverter to reduce mechanical and electrical load during start-up.
The exhaust line must be sized and routed to avoid exceeding +50 mbar back pressure. Do not install shut-off devices or restrictions in the discharge line; check exhaust pipe regularly for impurities. Higher back pressure requires manufacturer consultation.
Use only Elmo Rietschle approved oils (GEAR-LUBE 150 or ECO-GEAR-LUBE 150) to maintain the 20,000-hour oil change interval. Extreme conditions can reduce oil life to 5,000 hours. Oil quantity is 1.75 l; fill to middle of sight glass.
A defective coupling sprocket may lead to rotor shaft breakage. Inspect the coupling gear rim and fan at least once a year; replace if worn or damaged. Motor flange screws must be tightened to 84 Nm after refitting.
Operation outside this range requires consultation with the manufacturer. Ensure installation room ventilation and cooling air supply keep both ambient and intake temperatures within limits; cooling air must not be recirculated.
Selection & Integration Q&A
Choose the 401 for 380 m³/h at 50 Hz and continuous operation between 700 and 200 mbar (abs.). The 301 offers 290 m³/h and 5.5 kW for lower flows; the 501 provides 495 m³/h for higher capacity. The 401 balances medium duty with the same G 3 connections and 470 kg weight class as the 501.
For the VSD version, the frequency converter input is 3 AC 400 V –15% to 480 V +10%, 47–63 Hz, TN/TT networks. Direct-on-line starting is not permitted for motors above 5.2 kVA or starting current >60 A; use star-delta, soft starter, or frequency inverter. For the standard motor variant, consult the manufacturer for specific supply tolerances.
Install horizontally on a level foundation with max. 8° inclination in all directions. Provide at least 50 cm maintenance space and 30 cm clearance for cooling air inlets/outlets. Ambient and suction temperatures must be 5–40 °C; above 1000 m altitude, consult manufacturer for derating.
The base delivery excludes pressure monitoring (required for the OXY variant, which is not further defined in this document), suction filter cartridge (accessory, replace every 6 months), and condensate drain silencer (G ½) for XD. Spare parts like coupling star ZS1183380 and mesh filter ZS1114498 are available separately. Oil must be ordered separately: GEAR-LUBE 150 (1 l dose 7201706000).