Elmo Rietschle C-VLR 62
Elmo Rietschle C-VLR 62 — Claw Vacuum Pumps.
The C-VLR 62 is a contact-free rotary claw vacuum pump with passive cooling, driven by a standard three-phase motor via coupling; it is the smallest size in the C-VLR series, with a 62 m³/h suction capacity at 50 Hz. It differs from the larger C-VLR 122 and C-VLR 301/401/1000 by its compact 70 kg frame and G 1 1/2 suction port, and is intended for continuous evacuation or vacuum holding in closed systems within 400–1000 mbar (abs).
Elmo Rietschle C-VLR Series — Model Comparison & Selection
| Model | Operating principle | Noise level, dB | Weight, kg | Motor power, kW | Pumping speed, m³/h | Ultimate pressure, mbar |
|---|---|---|---|---|---|---|
| C-VLR 62 Current | — | — | — | — | — | — |
| C-VLR 1000 | claw | 82 | 757 | 18.5 | 950 | 200 |
| C-VLR 150 | Claw | — | — | — | — | — |
| C-VLR 301 | claw | 74 | 285 | 5.5 | 290 | 150 |
| C-VLR 401 | contact free running cla | 79 | 470 | — | — | — |
| C-VLR 60 | — | 78 | 47 | — | — | — |
Full specifications
Description
Construction and series positioning
- Double-shaft rotary piston design with non-contacting, dry-running claw rotors synchronized by an oil-lubricated gear pair; compression chamber separated from gearbox by special seals.
- Passive cooling (no fan-driven active cooling); driven by a standard three-phase motor via coupling and flange.
- Within the C-VLR series, the 62 is the smallest displacement size (62 m³/h at 50 Hz) and is distinguished from the C-VLR 122 by lower weight (70 kg vs 90 kg) and absence of a condensate purge port; larger siblings (301, 401, 1000) cover higher flows up to 950 m³/h.
- Available in standard CD and corrosion-protected XD versions; XD adds a protective coating and a condensate drain (distinct from the condensate purge port).
Behavior under load and media
- Intake pressure range for continuous vacuum: 400–1000 mbar (abs); ultimate pressure 100–150 mbar (abs) depending on frequency (lower value at 60 Hz).
- Maximum suction capacity 62 m³/h at 50 Hz; motor output 1.25 kW at 50 Hz, 1.5 kW at 60 Hz.
- Permissible ambient temperature and inlet temperature: 5–40 °C for both; operation outside requires manufacturer consultation.
- Maximum permissible back pressure +50 mbar; exhaust must not be restricted.
- Oil-lubricated gearbox requires GEAR-LUBE 150 (ISO VG 150) synthetic oil, fill volume 0.43 l.
Installation, connection and control
- Suction and discharge connections are G 1 1/2; suction flange includes a non-return valve.
- Minimum clearance 50 cm around machine for maintenance; cooling air inlets/outlets at least 30 cm from walls.
- Electrical supply: 3~ 230/400 V ±10% at 50 Hz or 265/460 V ±10% at 60 Hz; motor IP 55, insulation class F, per DIN EN 60034.
- Direction of rotation must be verified (counter-clockwise when viewed from the motor fan end); brief start max. 2 seconds.
- Frequency-converter variants use INVEOR M; wiring diagram on converter cover.
- Pressure monitoring system must be installed by user; pump must not operate without it.
Integration & Operating Notes
The exhaust air outlet must not be closed or restricted; maximum permissible back pressure is +50 mbar. Higher back pressure can overload the motor and damage the pump, so exhaust lines must be sized for low restriction and must not allow liquid accumulation.
Selection & Integration Q&A
Choose the C-VLR 62 when required suction capacity is up to 62 m³/h at 50 Hz and ultimate pressure of 100–150 mbar (abs) is sufficient. The C-VLR 122 doubles capacity to 120 m³/h and adds a condensate purge port; larger models (301, 401, 1000) cover higher flows up to 950 m³/h. Select the 62 for compact, lower-weight installations where space and weight are constrained.
Suction and discharge ports are G 1 1/2; use matching flanges and ensure the suction flange non-return valve is not obstructed. The motor requires a 3~ supply of 230/400 V ±10% at 50 Hz or 265/460 V ±10% at 60 Hz, with a user-provided main switch and motor protection switch. Verify rotation direction (counter-clockwise when viewed from the motor fan end) before continuous operation.
The pressure monitoring system is not included and must be installed by the user. A suction filter and vacuum limiting valve (ZUV) are available as accessories. Spare parts (including wear parts and seals) are listed in document E 882-31; oil GEAR-LUBE 150 must be ordered separately. No cables or spare coupling parts are included in base delivery.