Operating Instructions — C-VLR 62 (BA 882-31-AC, ed. 1.1 17.01.2022, EN)
Technical Reference Summary
Covered Models & Document Scope
Covers C-VLR 62 and C-VLR 122 contact-free claw vacuum pumps with active cooling, both without frequency converter (standard CD) and with frequency converter (variants Fxxx). Also covers XD variant with anti-corrosion protective coating. Document BA 882-31-AC-PT(BR), edition 1.1, 17.01.2022.
Section-by-Section Technical Breakdown
Describes the C-VLR 62, C-VLR 122 and frequency-converter versions, including component callouts, data plate layout and functional description. The pump is a contact-free claw-type vacuum pump driven by a standard three-phase motor via a coupling; gears and bearings are oil-lubricated in a gearbox. The XD model has an anti-corrosion protective coating.
- Vacuum connection G 1 1/2; exhaust air outlet G 1 1/2
- Suction flange with non-return valve
- Oil fill point, oil level sight glass, oil drain point
- Condensate purge only on XD model
- Hot surfaces > 70 °C marked
- Data plate includes type/size, serial number, year of construction, Data Matrix code, article number, speed 50/60 Hz, motor power 50/60 Hz, suction capacity, ultimate pressure (abs.)
Covers preparation of installation, mechanical installation, pipe connection and lubricating oil check. A clearance of at least 50 cm around the machine is required for maintenance work. Incorrect assembly and installation can damage the machine.
- Provide at least 50 cm free space around the machine for maintenance
- Connect vacuum and exhaust piping
- Check lubricating oil before commissioning
Describes connecting the power supply for motors without frequency converter and with frequency converter. The frequency converter is an INVEOR M; its connection diagram is on the cover of the frequency converter.
- Motor connection without frequency converter
- Motor connection with frequency converter (variants Fxxx)
- Frequency converter manual: INVEOR M, DOC02298769-0004
Covers commissioning checks, verification of direction of rotation, operation and condensate draining. Also covers decommissioning, storage and recommissioning.
- Check installation before commissioning
- Verify direction of rotation
- Drain condensate during operation
- Deactivate and store the machine for decommissioning
- Recommissioning procedure
Provides the maintenance table and procedures for cleaning the vacuum pump, lubricating oil level check and oil change, air filter and mesh filter, suction filter accessory, motor and coupling, frequency converter, repair/service and spare parts. Maintenance intervals and safety measures are specified.
- Maintenance table with intervals
- Check/replenish oil level; oil change
- Mesh filter and suction filter (accessory) maintenance
- Motor and coupling maintenance
- Frequency converter maintenance
- Spare parts documentation E 882-31
Technical data for variants without frequency converter and with frequency converter. Data plate ranges include frequency 20–60 Hz, ultimate pressure 150–100 mbar(abs.), suction capacity 44–135 m³/h, speed 1220–3590 rpm, motor power 1.05–2.9 kW.
- Frequency range: 20–60 Hz
- Ultimate pressure (abs.): 150–100 mbar
- Suction capacity: 44–135 m³/h
- Speed: 1220–3590 rpm
- Motor power: 1.05–2.9 kW
- Standard: EN 60034
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Minimum clearance of 50 cm around the machine is required for maintenance work. p.19 ↗ | Plan installation layout to allow access for maintenance and inspection. | C-VLR 62 and C-VLR 122 all variants |
| Vacuum connection and exhaust air outlet are G 1 1/2. p.14 ↗ | Use matching G 1 1/2 piping/fittings for suction and exhaust. | C-VLR 62 and C-VLR 122 |
| Suction flange is equipped with a non-return valve. p.14 ↗ | Prevents backflow when pump stops; consider system design accordingly. | C-VLR 62 and C-VLR 122 |
| Condensate purge is provided only on the XD model. p.14 ↗ | For condensate removal in standard CD models, alternative measures must be considered. | XD variant only |
| Surfaces marked > 70 °C are hot. p.14 ↗ | Provide protection or warning to prevent burns during operation and maintenance. | C-VLR 62 and C-VLR 122 |
| Data plate includes frequency range 20–60 Hz, ultimate pressure 150–100 mbar(abs.), suction capacity 44–135 m³/h, speed 1220–3590 rpm, motor power 1.05–2.9 kW. p.17 ↗ | Verify operating point and motor sizing against these ranges. | C-VLR 62 and C-VLR 122 |
| Motor complies with EN 60034. p.17 ↗ | Standard three-phase motor; ensure supply and protection coordination accordingly. | C-VLR 62 and C-VLR 122 |
| Frequency converter is INVEOR M; connection diagram is on the cover of the frequency converter. p.4 ↗ | Refer to INVEOR M manual DOC02298769-0004 for wiring and parameters. | Variants Fxxx with frequency converter |
| Gears and bearings are oil-lubricated in a gearbox; oil level must be checked before commissioning. p.18 ↗ | Verify oil level via sight glass and top up if necessary before first start. | C-VLR 62 and C-VLR 122 |
| Direction of rotation must be verified during commissioning. p.24 ↗ | Incorrect rotation can damage the pump; check before continuous operation. | C-VLR 62 and C-VLR 122 |
| Condensate must be drained during operation. p.24 ↗ | Regular condensate removal prevents accumulation and performance loss. | C-VLR 62 and C-VLR 122 |
| Spare parts are documented in E 882-31. p.4 ↗ | Use only specified spare parts for repair. | C-VLR 62 and C-VLR 122 |