Technical Data Sheet — C-VLR 301 vacuum pump (US)
Technical Reference Summary
Covered Models & Document Scope
Bombas de vacío de compresión sin contacto en seco de garra C-VLR 301, C-VLR 401, C-VLR 501 con motor NEMA Premium; variantes de 50 Hz y 60 Hz; tensiones nominales 3~ 400/690 V ±10 % (50 Hz) y 208-230/460 V ±10 % (60 Hz); versión opcional 'XD' con purga de condensado; filtro de aspiración estanco al vacío ZVF y arrancador de motor opcionales.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Suction capacity | 170 cfm p.1 ↗ | C-VLR 301, 50 Hz |
| Suction capacity | 205 cfm p.1 ↗ | C-VLR 301, 60 Hz |
| Suction capacity | 240 cfm p.1 ↗ | C-VLR 401, 50 Hz |
| Suction capacity | 285 cfm p.1 ↗ | C-VLR 401, 60 Hz |
| Suction capacity | 295 cfm p.1 ↗ | C-VLR 501, 50 Hz |
| Suction capacity | 355 cfm p.1 ↗ | C-VLR 501, 60 Hz |
| Ultimate vacuum continuous operation | 113 Torr - 25.5 in. HgV p.1 ↗ | C-VLR 301 |
| Ultimate vacuum continuous operation | 150 Torr - 24 in. HgV p.1 ↗ | C-VLR 401 |
| Ultimate vacuum continuous operation | 150 Torr - 24 in. HgV p.1 ↗ | C-VLR 501 |
| Rated voltage | 400 / 690 V ±10 % p.1 ↗ | 3~, 50 Hz |
| Rated voltage | 208 - 230 / 460 V ±10 % p.1 ↗ | 3~, 60 Hz |
| Motor rating | 5.5 kW p.1 ↗ | C-VLR 301, 50 Hz |
| Motor rating | 7.5 kW p.1 ↗ | C-VLR 401, 50 Hz |
| Motor rating | 11.0 kW p.1 ↗ | C-VLR 501, 50 Hz |
| Motor rating | 7.5 hp p.1 ↗ | C-VLR 301, 60 Hz |
| Motor rating | 12.0 hp p.1 ↗ | C-VLR 401, 60 Hz |
| Motor rating | 15.0 hp p.1 ↗ | C-VLR 501, 60 Hz |
| Full load amperage | 10.1 / 5.8 A p.1 ↗ | C-VLR 301, 50 Hz |
| Full load amperage | 13.9 / 8.06 A p.1 ↗ | C-VLR 401, 50 Hz |
| Full load amperage | 20.9 / 12.1 A p.1 ↗ | C-VLR 501, 50 Hz |
| Speed | 2950 rpm p.1 ↗ | 50 Hz |
| Speed | 3550 rpm p.1 ↗ | 60 Hz |
| Average noise level | 74 dB(A) p.1 ↗ | C-VLR 301, 50 Hz, EN ISO 3744 |
| Average noise level | 77 dB(A) p.1 ↗ | C-VLR 401, 50 Hz, EN ISO 3744 |
| Average noise level | 78 dB(A) p.1 ↗ | C-VLR 501, 50 Hz, EN ISO 3744 |
Operating Limits
- Rated voltage tolerance: ±10 % p.1 ↗
- Ultimate vacuum continuous operation: 113 Torr - 25.5 in. HgV (C-VLR 301); 150 Torr - 24 in. HgV (C-VLR 401/501) p.1 ↗
- Average noise level: 74-78 dB(A) at 50 Hz; 77-81 dB(A) at 60 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.1 ↗ | C-VLR | Product series: dry contactless compression claw vacuum pump |
| 6-8 p.1 ↗ | 301 / 401 / 501 | Size designation |
| voltage field p.1 ↗ | 400 / 690 | Rated voltage for 50 Hz operation, 3~, ±10 % |
| voltage field p.1 ↗ | 208 - 230 / 460 | Rated voltage for 60 Hz operation, 3~, ±10 % |
| version field p.2 ↗ | XD | Version with condensate drain (B2) |
| accessory field p.3 ↗ | ZVF | Vacuum-tight suction filter option |