Induztr
Engineering Digest Document Viewer Related Models

Operating Instructions — C-VLR 150 (BA 880-PT, EN)

Technical Reference Summary

Covered Models & Document Scope

This manual covers the C-VLR 150 and C-VLR 251 dry-running claw vacuum pumps (C-Series), including the C-VLR 251 (15) variant. Standard version CD and corrosion-protected version XD are defined. Document edition 1.3, 14.09.2023, BA 880-PT(BR).

Section-by-Section Technical Breakdown

pp. 14-18
Product overview and function

Describes the construction and operating principle of the C-VLR 150, C-VLR 251 and C-VLR 251 (15). The machines are oil-lubricated claw vacuum pumps with a separation between the gear chamber and the compression chamber by special seals. Drive is via an elastomer coupling from the motor.

  • C-VLR 150 and C-VLR 251 are claw-type dry-running vacuum pumps.
  • Gears and compression chamber are separated by special seals.
  • Drive is transmitted through an elastomer coupling.
  • Components: vacuum connection, exhaust air outlet, vacuum regulating valve, cooling air inlet/outlet, oil fill point, oil sight glass, oil drain point, intake filter, blow-off silencer, terminal box (251 (15)), intake filter valve (251 (15)).
  • Hot surfaces > 70 °C are marked.
pp. 19-22
Installation

Covers installation preparation, positioning, pipe connection, vacuum regulating/limiting valve, lubricating oil check and electrical connection. Piping longer than 3 m can cause performance loss; compensators are recommended to avoid pipe forces.

  • Connecting pipes longer than 3 m can reduce pumping capacity.
  • High forces and torques from piping must not act on the pump; use compensators.
  • Undersized and/or too-long suction lines reduce pumping capacity.
  • Check lubricating oil before commissioning.
  • Electrical supply connection is described in section 5.6.
pp. 23-25
Commissioning and decommissioning

Covers installation check, rotation direction check, operation, condensate draining, deactivation, storage and recommissioning. Rotation direction must be verified before operation.

  • Check the installation before first start-up.
  • Verify direction of rotation.
  • Drain condensate during operation.
  • Deactivation and storage procedures are given.
  • Recommissioning procedure is given.
pp. 26-33
Maintenance and repair

Covers operational safety, maintenance work, cleaning of the vacuum pump and vacuum regulating valve, oil level check and oil change, air filtration (vacuum-tight intake filter and filter mesh), motor and coupling, repair/overhaul and spare parts.

  • Clean the vacuum pump and vacuum regulating valve.
  • Check oil level and top up; change oil.
  • Service vacuum-tight intake filter and filter mesh.
  • Inspect motor and coupling.
  • Use original spare parts; repairs only by authorized workshops.
pp. 35-36
Faults

Fault table with symptom, cause and remedy. Includes overheating due to contaminated vacuum regulating valve, abnormal noise due to deposits on rotary pistons, and vibrating regulating valve.

  • Machine too hot: contaminated vacuum regulating valve causing permissible vacuum value to be exceeded; clean/replace valve (Chapter 7.5 / 7.10).
  • Abnormal noise: deposits on rotary pistons; clean working area and rotary pistons; contact Elmo Rietschle Service.
  • Vacuum regulating valve judders: replace valve (Chapter 7.10).
  • For other or irreparable faults, contact Elmo Rietschle Service.
pp. 38
Technical data

Technical data section referenced in the table of contents (page 38). The extracted text does not include the actual technical data table values.

  • Technical data are provided in section 10 on page 38.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Connecting pipes longer than 3 m can cause a reduction in pumping capacity. p.20 ↗ Keep suction lines as short as possible; account for pressure drop in system design. C-VLR 150 and C-VLR 251
High forces and torques from piping must not act on the pump; compensators are recommended. p.20 ↗ Use flexible compensators and proper pipe supports to avoid mechanical stress on the pump housing. C-VLR 150 and C-VLR 251
Undersized and/or too-long suction lines reduce the pumping capacity of the vacuum pump. p.20 ↗ Select suction line diameter generously and minimize length to preserve specified pumping speed. C-VLR 150 and C-VLR 251
Hot surfaces > 70 °C are present and marked on the machine. p.14 ↗ Provide guarding or warning and avoid contact during operation and after shutdown. C-VLR 150, C-VLR 251, C-VLR 251 (15)
The machine is a combination of vacuum pump and motor, ready to be connected. p.5 ↗ No separate drive assembly is required; verify motor data on the motor nameplate. C-VLR 150 and C-VLR 251
Final pressure (abs.) is the maximum vacuum reached by the pump when the suction opening is closed, expressed in mbar (abs.). p.5 ↗ Use this value for ultimate pressure specification; it is not the continuous operating suction pressure. C-VLR 150 and C-VLR 251
Continuous vacuum is the suction vacuum or suction pressure range in which the pump operates continuously; it is ≥ final vacuum and < atmospheric pressure. p.5 ↗ Ensure the application's continuous operating point lies within this range. C-VLR 150 and C-VLR 251
Noise emission is given as sound pressure level in dB(A) according to EN ISO 3744 at a specific load. p.5 ↗ Use this value for acoustic planning and compare with site requirements. C-VLR 150 and C-VLR 251
Version XD is a machine with corrosion protection coating; version CD is the standard version. p.5 ↗ Select XD for corrosive environments or process gases; CD for standard duty. C-VLR 150 and C-VLR 251
The vacuum regulating valve must be cleaned or replaced if contaminated, otherwise the permissible vacuum value may be exceeded and the machine overheats. p.36 ↗ Include the regulating valve in the maintenance schedule. C-VLR 150 and C-VLR 251
Deposits on the rotary pistons cause abnormal noise. p.36 ↗ Clean the working area and rotary pistons; contact Elmo Rietschle Service if deposits persist. C-VLR 150 and C-VLR 251
A juddering vacuum regulating valve is remedied by replacing the valve. p.36 ↗ Keep a spare regulating valve; replacement is covered in Chapter 7.10. C-VLR 150 and C-VLR 251
The C-VLR 251 (15) variant includes a terminal box (S1) and an intake filter valve (S2). p.16 ↗ Electrical connection and intake filter service differ for this variant. C-VLR 251 (15)
The machine is oil-lubricated; oil level must be checked and oil changed per maintenance schedule. p.28 ↗ Use the oil recommendation plate and maintain oil level between sight-glass marks. C-VLR 150 and C-VLR 251
The gear chamber and compression chamber are separated by special seals. p.17 ↗ Oil does not enter the compression chamber in normal operation; seal integrity is critical. C-VLR 150 and C-VLR 251
Drive is via an elastomer coupling from the motor. p.17 ↗ Check coupling element wear during maintenance. C-VLR 150 and C-VLR 251
The vacuum-tight intake filter and filter mesh require maintenance. p.30 ↗ Inspect and clean/replace intake filter elements to maintain pumping performance. C-VLR 150 and C-VLR 251
Repairs must be performed only by authorized workshops using original spare parts; otherwise warranty is void. p.5 ↗ Use Elmo Rietschle Service or authorized partners for repairs. C-VLR 150 and C-VLR 251

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
A máquina fica demasiado quente p.36 ↗ A válvula reguladora está contaminada, de modo que o valor de vácuo admissível foi excedido Limpar/Substituir a válvula reguladora Capítulo 7.5, Capítulo 7.10
A máquina gera um ruído anormal p.36 ↗ Sedimentações sobre o pistão rotativo Limpar a área de trabalho e os pistões rotativos; Elmo Rietschle Service
A válvula reguladora trepida p.36 ↗ Not stated Substituir válvula Capítulo 7.10