This manual covers the C-VLR 62 and C-VLR 122 contact-free rotary claw vacuum pumps, in standard (CD) and corrosion-protected (XD) versions, with and without frequency converter. It includes active cooling variants and accessories such as suction filter and vacuum limiting valve.

Section-by-Section Technical Breakdown

pp. 14-18
Product Overview and Function

Describes the C-VLR 62 and C-VLR 122 pump construction, including connections, oil fill, condensation drain (XD only), and the frequency-converter version. Explains the contact-free rotary claw operating principle and typical fields of application.

  • Vacuum connection G 1 1/2
  • Discharge outlet G 1 1/2
  • Suction flange with non-return valve
  • Oil fill and oil type plate
  • Condensate drain only on XD version
  • Frequency-converter version includes cooling air inlet, oil sight glass, oil drain, and blower silencer
pp. 19-20
Positioning and Pipe Connection

Covers preparation, positioning, pipe connection, and checking lubricating oil before commissioning. Ensures proper installation and oil level prior to electrical connection.

  • Prepare installation site
  • Position the pump
  • Connect piping
  • Check lubricating oil level
pp. 21-22
Electrical Connection

Details connecting the motor for machines without a frequency converter and for machines with a frequency converter. Includes supply connection requirements.

  • Motor connection without frequency converter
  • Motor connection with frequency converter
pp. 23-25
Commissioning and Operation

Describes installation checks, rotation direction verification, normal operation, condensate draining, shutdown, storage, and recommissioning.

  • Check installation before start-up
  • Verify direction of rotation
  • Drain condensate during operation
  • Stop and store the machine
  • Recommissioning procedure
pp. 26-33
Maintenance and Repair

Provides maintenance schedule and procedures for cleaning the vacuum pump, checking and changing lubricating oil, servicing air filters, motor and coupling, frequency converter, and ordering spare parts.

  • Maintenance table
  • Clean vacuum pump
  • Check and top up oil level
  • Change oil
  • Clean mesh filter and suction filter
  • Motor and coupling maintenance
  • Frequency converter maintenance
  • Spare parts ordering via list E 882-31
pp. 37-38
Technical Data

Lists technical specifications for variants without and with frequency converter, including frequency, ultimate pressure, pumping speed, speed, motor power, and voltage.

  • Variants without frequency converter
  • Variants with frequency converter

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Vacuum connection and discharge outlet are both G 1 1/2. p.14 ↗ Piping must be sized to G 1 1/2 to match pump ports. C-VLR 62 and C-VLR 122
Condensate drain is only present on the XD (corrosion-protected) version. p.14 ↗ XD variants require routing of condensate drain; CD variants do not have this drain. XD variants
Frequency-converter version includes a cooling air inlet, oil sight glass, oil drain, and blower silencer. p.16 ↗ Installation must provide cooling air access and allow oil inspection/draining. Variants with frequency converter
Maximum suction capacity is 62 m³/h or 120 m³/h at 50 Hz. p.18 ↗ Select piping and system components for at least these flow rates. C-VLR 62 and C-VLR 122
Data plate indicates frequency range 20–60 Hz, ultimate pressure 150–100 mbar(abs.), pumping speed 44–135 m³/h, speed 1220–3590 rpm, motor power 1.05–2.9 kW. p.17 ↗ Verify application requirements fall within these ranges when selecting a variant. C-VLR series
Spare parts must be ordered using spare parts list E 882-31 for C-VLR 62 | 122 active cooling. p.33 ↗ Use only original or manufacturer-approved spare parts to maintain warranty and liability. C-VLR 62 and C-VLR 122
Wear parts and seals are listed separately in the spare parts list. p.33 ↗ Include wear parts and seals in maintenance planning and spare parts inventory. C-VLR 62 and C-VLR 122
The machine is a ready-to-connect combination of vacuum pump and motor. p.5 ↗ No separate motor-pump assembly is required at installation. C-VLR series
CD designates standard version; XD designates corrosion-protected version. p.5 ↗ Choose XD for corrosive gas duty; CD for standard applications. C-VLR series