Operating Instructions — C-VLR 62 vacuum pump (BA 882-PC, ed. 1.0 28.03.2019, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the contactless claw vacuum pumps C-VLR 62 and C-VLR 122 with passive cooling, including the standard model (CD) and the corrosion-protective coated model (XD). The document is the operating instructions BA 882-PC-GB, edition 1.0 dated 28.03.2019.

Section-by-Section Technical Breakdown

pp. 12-15
Product overview and functioning

Describes the construction and operating principle of the C-VLR 62 and C-VLR 122 claw vacuum pumps. The pumps are double-shaft rotary piston machines with contact-free dry-running claw rotors synchronised by an oil-lubricated gear pair. The document identifies components, connections, data plate fields, fields of application and available accessories.

  • C-VLR 62: vacuum connection G 1 1/2, exhaust air outlet, inlet flange with non-return valve, cooling air inlet/outlet, oil filling point, oil sight glass, oil discharge point, exhaust silencer, vacuum relief valve (ZUV).
  • C-VLR 122: same as C-VLR 62 plus exhaust air outlet G 1 and condensate drain X.
  • Data plate includes type/size, serial number, year of construction, data matrix barcode, item number, speed 50/60 Hz, motor output 50/60 Hz, recommended oil type, operating mode, pumping capacity 50/60 Hz, final pressure (abs.) 50/60 Hz.
  • Fields of application: evacuation of closed systems or continuous vacuum within inlet pressure range 400–1000 mbar (abs.); maximum suction capacity 62 m3/h or 120 m3/h at 50 Hz.
  • XD model has corrosion-protective coating and is suitable for water-damp gases (water vapour).
  • Accessories: intake filter (paper or polyester) and vacuum relief valve (ZUV) set at factory for lowest permissible final pressure.
pp. 16-18
Installation

Provides requirements for preparing the installation site, mechanical installation, pipe connection, oil level check and electrical connection. Includes limits for inclination, cooling air clearance, back pressure and electrical tolerances.

  • Machine must be set up horizontally; maximum inclination 8° in all directions.
  • Cooling air inlets and outlets must be at least 30 cm away from adjacent walls.
  • Maximum permissible back pressure: +50 mbar.
  • Only screw in pipes by hand; use flexible connections if necessary.
  • Oil level must be checked through the oil sight glass and topped up to the middle of the sight glass.
  • Electrical installation by qualified electrician per EN 60204; motor protection circuit breaker required.
  • Permissible voltage deviation ±5%, frequency deviation ±2%.
  • Motors comply with DIN EN 60034, protection class IP 55, insulation class F.
pp. 19-21
Commissioning and decommissioning

Covers start-up checks, rotation direction verification, after-run procedure, decommissioning steps and recommissioning. Includes safety warnings for hot surfaces, suction hazards and noise.

  • Check rotation direction with phase sequence indicator; when looking at motor blower, it must rotate counter-clockwise.
  • Start motor briefly (max. two seconds) to check direction of rotation.
  • Before putting out of operation for more than 2 hours, run pump at -700 mbar (abs.) for at least 15–30 minutes with dry air.
  • Drain condensate from silencer (VLR 122) before decommissioning.
  • Decommissioning: switch off, allow to cool, close cut-off devices, disconnect power, depressurise slowly, remove pipes, drain condensate, seal connections.
pp. 22-29
Maintenance and repair

Defines maintenance intervals and procedures for oil change, air filter cleaning/replacement and coupling inspection. Includes safety instructions and spare parts ordering information.

  • Monthly: check pipes and screws for leaks, clean ventilation slots, check oil level, check/clean/replace air filters, drain condensate (VLR 122).
  • Oil change every 20,000 operating hours; extreme load can reduce oil life to 5,000 hours.
  • Oil type: Elmo Rietschle GEAR-LUBE 150 synthetic oil, viscosity ISO VG 150 per DIN 3448.
  • Check couplings for wear at least once per year.
  • General overhaul at 40,000 hours by Elmo Rietschle Service.
  • Mesh filter: clean or replace monthly by washing or blowing off.
  • Intake filter cartridge: clean monthly, replace every six months.
pp. 30
Malfunctions: Causes and elimination

Troubleshooting table listing malfunctions, probable causes and corrective actions. Covers motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating and unusual noise.

  • Machine switched off by motor protection switch: check mains voltage/frequency, motor terminal connection, motor protection switch setting.
  • Suction capacity insufficient: clean/replace air filter, check inlet pipe length/diameter, check for leaks.
  • Final pressure not reached: check for leaks, clean/replace air filter.
  • Machine gets too hot: check ambient/inlet temperatures, cooling air supply, clean ventilation slots.
  • Strange noise: clean working space and rotary piston; contact Elmo Rietschle Service.
pp. 31
Technical Data

Lists technical specifications for C-VLR 62 and C-VLR 122, including sound pressure level, weight, dimensions, connections, oil volume, voltage, current and motor output.

  • C-VLR 62: sound pressure level 79 dB(A) at 50 Hz, 82 dB(A) at 60 Hz; sound power level 85 dB(A).
  • C-VLR 62: weight 70 kg, length 707 mm, width 439 mm, height 277 mm.
  • C-VLR 122: weight 90 kg, length 776 mm, width 378 mm, height 277 mm.
  • Vacuum connection G 1 1/2; oil filled volume 0.43 l.
  • Rated voltage 3~: 230/400 V ±10% at 50 Hz; 265/460 V ±10% at 60 Hz.
  • Current consumption C-VLR 62: 4.89/2.81 A at 50 Hz; 4.84/2.79 A at 60 Hz.
  • Motor output C-VLR 62: 1.25 kW at 50 Hz; 1.5 kW at 60 Hz.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Maximum inclination for operation: 8° in all directions. p.16 ↗ Machine must be installed horizontally; ensure floor is plane and even. C-VLR 62 and C-VLR 122
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.16 ↗ Ensure sufficient clearance for cooling air flow to prevent overheating. C-VLR 62 and C-VLR 122
Maximum permissible back pressure: +50 mbar. p.17 ↗ Do not close or restrict exhaust air openings; prevent liquid accumulation in exhaust line. C-VLR 62 and C-VLR 122
Permissible voltage deviation: ±5%; frequency deviation: ±2%. p.18 ↗ Verify mains supply matches motor data plate before connection. C-VLR 62 and C-VLR 122
Motor protection: IP 55, insulation class F, per DIN EN 60034. p.18 ↗ Use motor protection circuit breaker with delayed switch off to accommodate temporary excess current at cold start. C-VLR 62 and C-VLR 122
Oil change interval: 20,000 operating hours; extreme load can reduce to 5,000 hours. p.23 ↗ Use Elmo Rietschle approved oil (GEAR-LUBE 150, ISO VG 150) to maintain interval. C-VLR 62 and C-VLR 122
Oil filled volume: 0.43 l. p.31 ↗ Fill oil to middle of sight glass; if changing oil type, empty tank completely. C-VLR 62 and C-VLR 122
Recommended oil: GEAR-LUBE 150 synthetic oil, viscosity ISO VG 150 per DIN 3448. p.25 ↗ Use only approved oil to maintain warranty and performance. C-VLR 62 and C-VLR 122
After-run procedure: run at -700 mbar (abs.) for at least 15–30 minutes with dry air before shutdown >2 hours. p.20 ↗ Prevents condensate and impurity deposits that can damage machine. C-VLR 62 and C-VLR 122
Rotation direction check: start motor briefly (max. 2 seconds); when looking at motor blower, it must rotate counter-clockwise. p.20 ↗ Wrong rotation can damage machine and cause injury; use phase sequence indicator. C-VLR 62 and C-VLR 122
Maximum suction capacity: 62 m3/h or 120 m3/h at 50 Hz. p.15 ↗ Select model based on required pumping speed; inlet pressure range 400–1000 mbar (abs.). C-VLR 62 (62 m3/h) and C-VLR 122 (120 m3/h)
Sound pressure level: 79 dB(A) at 50 Hz, 82 dB(A) at 60 Hz (C-VLR 62); tolerance ±3 dB(A). p.31 ↗ Use ear protection when spending long time near running machine. C-VLR 62
Weight: C-VLR 62 = 70 kg; C-VLR 122 = 90 kg. p.31 ↗ Ensure bearing surface can carry weight; secure machine against tipping. C-VLR 62 and C-VLR 122
Rated voltage 3~: 230/400 V ±10% at 50 Hz; 265/460 V ±10% at 60 Hz. p.31 ↗ Verify motor data plate matches mains network. C-VLR 62
Motor output: 1.25 kW at 50 Hz; 1.5 kW at 60 Hz (C-VLR 62). p.31 ↗ Size motor protection and supply accordingly. C-VLR 62
Ambient and inlet temperature range: 5 to 40 °C. p.7 ↗ Contact manufacturer for temperatures outside this range. C-VLR 62 and C-VLR 122
Storage conditions: relative humidity 0–80%, temperature -10 to +60 °C, max. 6 months. p.11 ↗ Store in dry, dust-free, vibration-free environment. C-VLR 62 and C-VLR 122
Coupling sprocket must be checked for wear at least once per year. p.28 ↗ Frequent starting and high ambient temperature reduce sprocket lifetime. C-VLR 62 and C-VLR 122
Intake filter cartridge should be replaced every six months. p.27 ↗ Clean monthly by blowing off from inside to outside; separation efficiency deteriorates with cleaning. C-VLR 62 and C-VLR 122 with intake filter accessory
General overhaul at 40,000 hours by Elmo Rietschle Service. p.23 ↗ Plan for service intervention at this interval. C-VLR 62 and C-VLR 122

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
The machine is switched off by the motor protection switch p.30 ↗ Mains voltage/ Frequency does not correspond with the motor data Get it checked by an electrician Chapter 5.5
The machine is switched off by the motor protection switch p.30 ↗ Connection to motor terminal board is not correct Get it checked by an electrician Chapter 5.5
The machine is switched off by the motor protection switch p.30 ↗ Motor protection switch is not set correctly Get it checked by an electrician Chapter 5.5
Motor protection switch is triggered too quickly p.30 ↗ Motor protection switch is not set correctly Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Suction capacity is insufficient p.30 ↗ Air filter is polluted Clean / replace the air filter Chapter 7.2.2, Chapter 7.4
Suction capacity is insufficient p.30 ↗ The inlet pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Suction capacity is insufficient p.30 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Final pressure (max. vacuum) is not reached p.30 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Final pressure (max. vacuum) is not reached p.30 ↗ Air filter is polluted Clean / replace the air filter Chapter 7.2.2, Chapter 7.4
Machine gets too hot p.30 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.3
Machine gets too hot p.30 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.30 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.2
The machine makes a strange noise p.30 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service