Operating Instructions — C-VLR 62 (BA 882-PC, ed. 1.0 28.03.2019, EN)

Technical Reference Summary

Covered Models & Document Scope

This operating manual (BA 882-PC-PT(BR), edition 1.0, 28.03.2019) covers the contact-free, free-moving claw vacuum pumps C-VLR 62 and C-VLR 122 with passive cooling. It includes the XD design variant (with protective coating) and mentions the ZUV vacuum limiting valve option (section 5.6 covers pumps without ZUV).

Section-by-Section Technical Breakdown

pp. 12
Product overview C-VLR 62

Component overview of the C-VLR 62 with passive cooling (XD design). Identifies the vacuum connection G 1 1/2, exhaust air outlet, suction flange with check valve, cooling air inlet/outlet, oil fill point, oil level sight glass, oil drain point, oil recommendation plate, data plate, direction-of-rotation arrow, drive motor, motor data plate, hot surfaces > 70 °C, and blow-off silencer.

  • Vacuum connection A: G 1 1/2
  • Suction flange D with check valve
  • Cooling air inlet E and ZUV cooling air inlet E1
  • Oil fill point H, oil level sight glass I, oil drain point K
  • Hot surfaces Q > 70 °C
  • Blow-off silencer Z
  • Vacuum limiting valve ZUV
pp. 13
Product overview C-VLR 122

Component overview of the C-VLR 122 with passive cooling (XD design). Similar to the C-VLR 62 but with exhaust air outlet G 1 and an additional condensate purge X.

  • Vacuum connection A: G 1 1/2
  • Exhaust air outlet B: G 1
  • Condensate purge X
  • Oil fill point H, oil level sight glass I, oil drain point K
  • Hot surfaces Q > 70 °C
  • Blow-off silencer Z
  • Vacuum limiting valve ZUV
pp. 14
Data plate

Explains the data plate fields: type/size (mechanical variant), serial number, year of construction, Data Matrix barcode, article number, motor power at 50/60 Hz, recommended oil type, suction capacity at 50/60 Hz, and ultimate pressure (abs.) at 50/60 Hz.

  • Field 1: Type/size (mechanical variant)
  • Field 2: Serial number
  • Field 3: Year of construction
  • Field 4: Data Matrix barcode
  • Field 5: Article number
  • Field 7: Motor power 50 Hz / 60 Hz
  • Field 8: Recommended oil type
  • Field 10: Suction capacity 50 Hz / 60 Hz
  • Field 11: Ultimate pressure (abs.) 50 Hz / 60 Hz
pp. 14
Description

Describes the functional principle: two intermeshing claw rotors driven by a gear pair in the transmission. The synchronizing gears and bearings are oil-lubricated in a gearbox, and the compression chambers are separated by special seals. Drive is via a coupling from a standard three-phase motor with flange.

  • Contact-free, free-moving claw principle
  • Gear pair in transmission drives the rotors
  • Synchronizing gears and bearings oil-lubricated in gearbox
  • Compression chambers separated by special seals
  • Drive via coupling from standard three-phase motor with flange
pp. 15
Areas of use

The C-VLR 62/122 are claw vacuum pumps for generating negative pressure. Model XD has a protective coating for certain applications.

  • Generation of vacuum / negative pressure
  • Model XD: vacuum pump with protective coating
pp. 15
Accessories

Accessories include a suction filter (4.6.1) and a vacuum limiting valve (4.6.2).

  • Suction filter
  • Vacuum limiting valve (ZUV)
pp. 16-18
Installation

Covers preparing the installation, mounting, connecting pipes, checking lubricating oil, and connecting the power supply including motor connection. Section 5.6 addresses pumps without vacuum limiting valve.

  • Prepare installation (5.1)
  • Installation (5.2)
  • Connect pipes (5.3)
  • Check lubricating oil (5.4)
  • Connect power supply (5.5)
  • Connect motor (5.5.1)
  • Pump without vacuum limiting valve (5.6)
pp. 19-21
Commissioning and decommissioning

Covers commissioning including checking direction of rotation, decommissioning, residual operation, shutting down the machine, and recommissioning.

  • Commissioning (6.1)
  • Check direction of rotation (6.1.1)
  • Decommissioning (6.2)
  • Residual operation (6.2.1)
  • Shut down the machine (6.2.2)
  • Recommissioning (6.3)
pp. 22-29
Maintenance and repair

Covers ensuring operational safety, maintenance activities including oil change, air filter, coupling, repair/service, and spare parts.

  • Ensure operational safety (7.1)
  • Maintenance activities (7.2)
  • Oil change (7.2.1)
  • Air filter (7.2.2)
  • Coupling (7.2.3)
  • Repair/service (7.3)
  • Spare parts (7.4)
pp. 30
Malfunctions: causes and remedies

Troubleshooting section listing malfunctions, their causes, and remedies.

  • Fault table with causes and remedies
pp. 31
Technical data

Technical specifications for the C-VLR 62 and C-VLR 122.

  • Technical data tables

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Vacuum connection is G 1 1/2 for both C-VLR 62 and C-VLR 122. p.12 ↗ Piping must be sized and fitted with G 1 1/2 mating connections. C-VLR 62 and C-VLR 122
Exhaust air outlet is G 1 on the C-VLR 122; the C-VLR 62 overview does not specify a thread size for the exhaust outlet. p.13 ↗ Exhaust piping for the C-VLR 122 must use G 1 fittings. C-VLR 122
Hot surfaces can exceed 70 °C. p.12 ↗ Provide guarding or warning and avoid contact during operation and after shutdown. C-VLR 62 and C-VLR 122
The C-VLR 122 has a condensate purge X; the C-VLR 62 overview does not list this component. p.13 ↗ Condensate removal provisions differ between models; C-VLR 122 includes a dedicated purge point. C-VLR 122
The pump is driven by a standard three-phase motor via a coupling with flange. p.14 ↗ Motor replacement must match the flange and coupling arrangement. C-VLR 62 and C-VLR 122
Synchronizing gears and bearings are oil-lubricated in a gearbox; compression chambers are separated by special seals. p.14 ↗ Oil type and level are critical; use the oil type stated on the data plate. C-VLR 62 and C-VLR 122
Data plate includes motor power, suction capacity, and ultimate pressure at both 50 Hz and 60 Hz. p.14 ↗ Verify actual performance values from the unit's data plate for the applicable frequency. C-VLR 62 and C-VLR 122
Model XD has a protective coating. p.15 ↗ XD variant is intended for applications requiring surface protection; confirm compatibility with process media. XD design variant
A vacuum limiting valve (ZUV) is available as an accessory; section 5.6 covers pumps without ZUV. p.15 ↗ Installation and operation differ depending on whether the ZUV is fitted. C-VLR 62 and C-VLR 122
A suction filter is available as an accessory. p.15 ↗ Use a suction filter to protect the pump from ingress of particles. C-VLR 62 and C-VLR 122
Direction of rotation must be checked during commissioning. p.20 ↗ Incorrect rotation can damage the pump; verify before continuous operation. C-VLR 62 and C-VLR 122
Condensate must be drained from the silencer regularly and depending on use. p.20 ↗ Establish a condensate drain schedule to prevent damage and starting problems. C-VLR 62 and C-VLR 122
Residual operation of the vacuum pump is recommended depending on use. p.20 ↗ Run the pump residual (e.g., with open suction) to remove moisture before shutdown. C-VLR 62 and C-VLR 122
Oil change, air filter, and coupling maintenance are specified maintenance activities. p.23 ↗ Plan maintenance intervals for oil, air filter, and coupling inspection/replacement. C-VLR 62 and C-VLR 122
Spare parts are listed in spare parts document E 882. p.4 ↗ Order spare parts using document E 882. C-VLR 62 and C-VLR 122
Technical data are provided in section 9. p.31 ↗ Refer to section 9 for model-specific performance and limits. C-VLR 62 and C-VLR 122