Operating Instructions — C-VLR 301 vacuum pump (BA 885-EN, ed. 1.2 11.04.2021, EN)
Technical Reference Summary
Covered Models & Document Scope
Covers the C-VLR 301 contact-free running claw vacuum pump in standard design (CD) and corrosion-protective coated design (XD) for damp gases/water vapour. Document BA 885-EN, edition 1.2, 11.04.2021.
Section-by-Section Technical Breakdown
Describes the C-VLR 301 as a double-shaft, contact-free rotary claw vacuum pump with dry-running claw rotors synchronised by an oil-lubricated gear pair. The gearbox and compression chamber are separated by special seals; an integral non-return valve and vacuum relief valve are incorporated. Cooling is by a drum fan drawing fresh air between compressor and insulation hood.
- Double-shaft rotary piston vacuum pump with non-contacting dry claws
- Gear pair in oil-filled gearbox synchronises counter-rotating rotors
- Integral non-return valve prevents ventilation of evacuated system after stop
- Vacuum relief valve incorporated into the machine
- Drum fan draws cooling air through cooling air inlet (Fig. 2/E) and discharges at outlet (Fig. 2/F)
- Driven via coupling by flanged three-phase standard motor
- XD model has condensate drain (Fig. 2/B2) and corrosion-protective coating
Defines continuous operation between 700 mbar (abs.) and 150 mbar (abs.) inlet pressure. Evacuated closed-system volume must not exceed 2% of nominal pumping capacity. Pumping capacity with unrestricted suction is 290 m3/h at 50 Hz.
- Continuous operation at any pressure between 700 mbar (abs.) and 150 mbar (abs.) inlet pressure
- Closed-system volume to be evacuated max. 2% of nominal pumping capacity
- Pumping capacity 290 m3/h at 50 Hz with unrestricted suction
- XD design suitable for water-damp gases (water vapour)
- Frequent switching (~10 times/hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits
- Outdoor installation requires protection from environmental influences (e.g. protective roof)
Covers preparation, mechanical installation, pipe connection, oil check and electrical connection. Machine must be set up horizontally with max. 8° inclination, secured against tipping, with at least 50 cm maintenance space and 30 cm clearance from walls for cooling air. Electrical installation per EN 60204 by qualified electrician with motor protection switch.
- Max. inclination 8° in all directions; floor must be plane and even
- Maintenance space at least 50 cm around machine
- Cooling air inlets/outlets at least 30 cm from adjacent walls; exhaust air must not be re-sucked
- Ambient temperature min. +5 °C, max. +40 °C
- Maximum permissible back pressure +50 mbar; exhaust opening must not be closed or restricted
- Only screw in pipes by hand; use flexible connections/compensators if necessary
- Oil filled to middle of oil sight glass (Fig. 2/I)
- Electrical installation per EN 60204; main switch and motor protection switch provided by user
- Permissible tolerances: ±5 % voltage deviation, ±2 % frequency deviation
- Motor protection class IP 55, insulation class F, per DIN EN 60034
Start-up requires an installation check and rotation direction check. Motor must rotate counter-clockwise when viewed at the motor blower; brief start max. two seconds. Before shutdown for more than 2 hours, run pump at 700 mbar (abs.) with dry air for 15-30 minutes to remove moisture and pollution.
- Installation check: no transport damage, safe horizontal standing, leak-tight pipe connections, tight screw/flange connections, correct electrical connection, adequate ventilation, oil filled and checked, cleaned pump and pipelines
- Check rotation direction with phase sequence indicator (clockwise); brief start max. two seconds
- When looking at motor blower, it must rotate counter-clockwise
- Keep 1 m distance to outlet and inlet connections during rotation check
- Before shutdown >2 hours or decommissioning: run at 700 mbar (abs.) with dry air for at least 15-30 minutes
- XD model: regularly discharge condensate from silencer through condensate drain
- Machine only allowed to be switched on again after it stands still
Maintenance includes cleaning the vacuum pump, checking/refilling oil, oil change, air filter/mesh filter service, and motor/coupling checks. Cleaning and oil change intervals depend on operating time, conditions and oil type. Before maintenance, disconnect power and secure against restart; allow machine to cool.
- Cleaning and oil change intervals depend on load (operating time, conditions) and oil type
- Intake filter and gas ballast valve cleaning intervals may be shorter with polluted media/environment
- Safety devices and guards on motor fans and ventilators may not be removed
- Disconnect machine and secure against accidental switching before maintenance
- Works on electrical installation only by electrician; repairs only by authorised specialists
Table of malfunctions with causes and elimination measures. Covers motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating, and strange noise. Never restart after automatic shut-off without finding and remedying the cause.
- Never put pump back into operation after automatic shut-off without unequivocally finding and remedying the reason
- Motor protection switch must have overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1)
- Air filter pollution reduces suction capacity and final pressure
- Leaks in machine or system prevent reaching final pressure
- Deposits on rotary piston cause strange noise; clean working space and rotary piston
- Contact Elmo Rietschle Service for other malfunctions
Technical data chapter referenced for weight, sound pressure level and other performance data. Data sheet D 890 contains technical data and characteristic curves.
- See chapter 10 for weight and sound pressure level
- Data sheet D 890 shows pumping capacity dependency on intake pressure
- Output reduction noticeable when installed at more than 1000 m above sea level
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Continuous operation permitted at any pressure between 700 mbar (abs.) and 150 mbar (abs.) inlet pressure. p.16 ↗ | Select pump for applications within this inlet pressure range; operation outside requires manufacturer consultation. | C-VLR 301 |
| Pumping capacity with unrestricted suction is 290 m3/h at 50 Hz. p.16 ↗ | Use as nominal sizing value at 50 Hz; refer to data sheet D 890 for pressure-dependent capacity. | C-VLR 301 |
| When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity. p.16 ↗ | Size evacuated volume accordingly to avoid excessive evacuation time or overload. | C-VLR 301 |
| Maximum permissible back pressure is +50 mbar. p.8 ↗ | Exhaust line must not be restricted or blocked; higher process back pressures require manufacturer consultation. | C-VLR 301 |
| Ambient and inlet temperature must be between 5 °C and 40 °C. p.8 ↗ | Install in ventilated area within this temperature range; contact manufacturer for temperatures outside range. | C-VLR 301 |
| Machine may only be operated when set up horizontally; max. inclination 8° in all directions. p.17 ↗ | Mount on plane, even floor and secure against tipping and falling. | C-VLR 301 |
| Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; cooling air coming out must not be sucked in again. p.17 ↗ | Maintain clearance to walls and prevent hot exhaust air recirculation to avoid overheating. | C-VLR 301 |
| For maintenance works, provide for a space of at least 50 cm around the machine. p.17 ↗ | Plan installation layout with adequate access for maintenance. | C-VLR 301 |
| Permissible voltage deviation ±5 %, frequency deviation ±2 %. p.19 ↗ | Verify mains supply at installation location complies with motor data plate before connection. | C-VLR 301 |
| Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.19 ↗ | Suitable for dusty/damp industrial environments within IP 55 rating. | C-VLR 301 |
| Motor must rotate counter-clockwise when looking at the motor blower; check with phase sequence indicator (clockwise). p.21 ↗ | Verify rotation direction before commissioning; wrong direction can damage machine and cause injury. | C-VLR 301 |
| Brief start for rotation check must not exceed two seconds. p.21 ↗ | Limit test run to avoid damage from wrong rotation direction. | C-VLR 301 |
| Before shutdown for more than 2 hours or decommissioning, run pump at 700 mbar (abs.) with dry air for at least 15-30 minutes. p.22 ↗ | Prevents condensate and impurity deposits on rotors and casing that could prevent restart. | C-VLR 301 |
| Oil level must be filled to the middle of the oil sight glass. p.18 ↗ | Check oil level through sight glass (Fig. 2/I) and top up at oil filling point (Fig. 2/H) as needed. | C-VLR 301 |
| Storage temperature range -20 °C to +70 °C; relative air humidity max. 80 %; store dust-free, dry, vibration-free, protected from sun radiation; do not store more than 6 months. p.13 ↗ | Observe storage conditions to prevent material damage; close openings air-tight. | C-VLR 301 |
| Output reduction is noticeable when installed at more than 1000 m above sea level. p.18 ↗ | Contact manufacturer for high-altitude installations. | C-VLR 301 |
| Frequent switching at regular intervals of approx. 10 times per hour or higher ambient/inlet temperatures may exceed excess temperature limit of motor winding and bearings. p.16 ↗ | Contact manufacturer for such operating conditions to avoid overheating. | C-VLR 301 |
| Surface temperatures on components may rise above 70 °C at operating temperature. p.20 ↗ | Wear protective gloves and avoid touching hot surfaces marked with warning signs. | C-VLR 301 |
| Standard model suitable for non-explosive, non-combustible, non-aggressive, non-poisonous dry gases and gas-air mixtures; XD model additionally for damp gases and water vapour. p.8 ↗ | Select XD variant for water vapour or damp gas applications. | C-VLR 301 CD and XD |
| Motor protection switch must have overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1). p.30 ↗ | Select motor protection switch with delayed switch-off to avoid nuisance tripping during cold start. | C-VLR 301 |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.30 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.30 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.30 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.30 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1) | |
| Suction capacity is insufficient p.30 ↗ | Air filter is polluted | Clean/replace air filter | Chapter 7.6, Chapter 7.9 |
| Suction capacity is insufficient p.30 ↗ | The inlet pipe is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| Suction capacity is insufficient p.30 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | Chapter 5.3 |
| Final pressure (max. vacuum) is not reached p.30 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | Chapter 5.3 |
| Final pressure (max. vacuum) is not reached p.30 ↗ | Air filter is polluted | Clean/replace air filter | Chapter 7.6, Chapter 7.9 |
| Machine gets too hot p.30 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Machine gets too hot p.30 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Machine gets too hot p.30 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.4 |
| The machine makes a strange noise p.30 ↗ | Deposits on the rotary piston | Clean the working space and the rotary piston | Elmo Rietschle Service |