Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — C-VLR 301 vacuum pump DE/EN)

Technical Reference Summary

Covered Models & Document Scope

C-VLR 301 vacuum pump, 50 Hz nominal data; 60 Hz values not stated. Voltage variants C-VLR X01 xx VI, SI, Wx, Ux, Tx for other voltages (50/60 Hz, Δ/Y).

Technical Data

Parameter Value Condition
Suction capacity 290 m³/h p.2 ↗ C-VLR 301, 50 Hz
Suction capacity – m³/h p.2 ↗ C-VLR 301, 60 Hz
Ultimate vacuum at continuous operation 150 mbar (abs.) p.2 ↗ C-VLR 301
Rated voltage 400 / 690 V ± 10 % p.2 ↗ C-VLR 301, 3~, 50 Hz
Rated voltage – V p.2 ↗ C-VLR 301, 60 Hz
Motor rating 5,5 kW p.2 ↗ C-VLR 301, 50 Hz
Motor rating – kW p.2 ↗ C-VLR 301, 60 Hz
Current drawn 10,2 / 5,89 A p.2 ↗ C-VLR 301, 50 Hz
Current drawn – A p.2 ↗ C-VLR 301, 60 Hz
Motor efficiency 90,9 % p.2 ↗ C-VLR 301, 50 Hz
Motor efficiency – % p.2 ↗ C-VLR 301, 60 Hz
Speed 2935 min⁻¹ p.2 ↗ C-VLR 301, 50 Hz
Speed – min⁻¹ p.2 ↗ C-VLR 301, 60 Hz
Average noise level 74 dB(A) p.2 ↗ C-VLR 301, EN ISO 3744, 50 Hz
Average noise level – dB(A) p.2 ↗ C-VLR 301, EN ISO 3744, 60 Hz
Max. weight 294 kg p.2 ↗ C-VLR 301
Oil capacity 1,5 l p.2 ↗ C-VLR 301
Motor protection switch 160 / 63 p.3 ↗ C-VLR 301, 50 Hz

Operating Limits

  • Voltage tolerance: ±10 % p.2 ↗
  • Ultimate vacuum at continuous operation: 150 mbar (abs.) p.2 ↗
  • Max. weight: 294 kg p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ C-VLR Product series (vacuum pump)
6-8 p.2 ↗ 301 Size / type designation
9-10 p.2 ↗ X01 Version field (as printed in voltage variant table)
11-12 p.2 ↗ xx Placeholder for option/variant field
13-14 p.2 ↗ VI Voltage variant: 200 V Δ / 346 V Y (50 Hz)
13-14 p.2 ↗ SI Voltage variant: 200 V Δ / 230 V Δ / 400 V Y (50 Hz)
13-14 p.2 ↗ Wx Voltage variant: no values printed
13-14 p.2 ↗ Ux Voltage variant: 330 V Δ / 380 V Δ / 660 V Y (50 Hz)
13-14 p.2 ↗ Tx Voltage variant: 200 V Δ / 400 V Δ / 690 V Y (50 Hz)