BINDER KB ECO 1020
BINDER KB ECO 1020 — Incubators with Temperature 0…70 °C.
The KB ECO 1020 is a 1,020 L thermoelectric (Peltier) cooling incubator with a 0–70 °C working range and 0.1 K uniformity, the largest chamber in the KB ECO series. It is distinguished from smaller siblings (240/400/720) by its 973 mm interior width and 150 kg permitted load, serving long-term storage and incubation at 4–37 °C in pharmaceutical and microbiological workflows.
Direct drop-in replacements
BINDER KB ECO Series — Model Comparison & Selection
| Model | Temperature, °C | Depth, cm | Height, cm | Interior volume, L | Interior width, mm | Load per rack, kg |
|---|---|---|---|---|---|---|
| KB ECO 1020 Current | 0–70 | 114.9 | 192.5 | 1020 | 973 | 45 |
| KB ECO 240 | 0–70 | 79.6 | 146.1 | 247 | 650 | 30 |
| KB ECO 400 | 0–70 | 79.6 | 194.6 | 400 | 650 | 30 |
| KB ECO 720 | 0–70 | 88.5 | 192.5 | 700 | 973 | 45 |
Full specifications
| Temperature | 0...70 °C |
| Interior volume | 1020 L |
| Load per rack | 45 kg |
| Max. heat compensation | 500 W |
| Nominal power | 1.3 kW |
| Permitted load | 150 kg (both variants) |
| Temperature fluctuation | 0.1 K |
| Temperature uniformity | 0.1 K |
| Back wall clearance | 100 mm (both variants) |
| Side wall clearance | 100 mm (both variants) |
| Article Number mfr | 9020 |
| Recovery time after door was opened for 30 s at 37°C mfr | 4 min |
| Depth | 1149 mm (both variants) |
| Height | 1925 mm (both variants) |
| Interior width | 973 mm (both variants) |
| Width | 1250 mm (both variants) |
| Net weight of the unit (empty) mfr | 327 kg |
| Power frequency | 50 Hz |
| Rated voltage | 200...230 V |
| Unit fuse | 16.0 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The KB ECO 1020 uses Peltier (thermoelectric) cooling with no refrigerant circuit; the RD4 chamber controller manages set-points, alarms and data recording.
- Within the KB ECO series it is the largest model: 1,020 L interior volume, 973 mm interior width, 1,250 mm net width, 1,925 mm net height and 1,149 mm net depth. Siblings 240, 400 and 720 share the same 0–70 °C range but smaller chambers.
- Two electrical variants exist: KBECO1020-230V (Art. 9020-0425, 200–230 V 1~, CEE 7/7 plug) and KBECO1020UL-120V (Art. 9020-0428, 100–120 V 1~, NEMA 5-20 plug). The 230 V variant draws 1.3 kW nominal; the UL variant 0.9 kW.
- Permitted load is 150 kg total, with 45 kg per rack; net empty weight is 327 kg.
Behavior under load and in operation
- Temperature fluctuation and uniformity are both 0.1 K; recovery after a 30 s door opening at 37 °C is 4 min.
- Maximum heat compensation is 500 W, which bounds the heat input from loaded samples that the Peltier system can offset while holding set-point.
- Intended cultivation range for microorganisms is 4–37 °C, covering refrigerated storage (4 °C), incubation (20–25 °C, 37 °C) and alternating temperature programs via automatic set-point switchover.
- Overtemperature protection is class 3.1 per DIN 12880:2007, with a class 1 over-temperature protective device; both must be configured and function-checked.
Installation, control and operation
- Minimum wall clearance is 100 mm at the back and 100 mm at the sides; installation in unventilated recesses is prohibited to allow heat dispersal.
- IP protection is 20 (EN 60529): the chamber must be kept splash-proof and dry during operation, cleaning and maintenance.
- The RD4 controller supports date- or cycle-based automatic set-point switchover, Idle mode, tolerance-range alarms with delay, audible buzzer, program start/stop, Ethernet networking and a DL1 data recorder with configurable storage rate.
- Data transfer is via USB stick (import/export); APT-COM™ 4 software can network up to 100 chambers to a PC.
- Defrosting during refrigerating operation and anti-condensation protection are controller functions described in the manual.
Integration & Operating Notes
The 230 V model requires 200–230 V 1~ 50/60 Hz sized for 5.8 A nominal current (1.3 kW), while the UL model requires 100–120 V sized for 7.5 A (0.9 kW). The unit fuse is 16.0 A; connecting a variant to the wrong voltage class will prevent startup or damage the Peltier/controller electronics.
The chamber must not be installed in unventilated recesses; prescribed minimum distances of 100 mm at the rear and 100 mm at the sides are required for heat dispersal. Violating these clearances risks overheating damage and degraded Peltier cooling performance.
The permitted load is 150 kg for the chamber and 45 kg per rack. Exceeding these limits can deform racks or the chamber interior and is outside the validated mechanical design; also account for the 500 W maximum heat compensation when loading heat-generating samples.
Loading material must not contain corrosive ingredients (particularly acids and halides) that attack stainless steel, aluminum and copper components, and the chamber must not be operated in potentially explosive areas. Corrosive damage from such ingredients is excluded from BINDER liability.
Maintenance must be performed at least once a year by licensed electricians or experts authorized by BINDER; warranty is void if non-authorized personnel perform it. An annual repeat electrical inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 is required, plus tests before initial start-up and before resuming operation after maintenance or repair.
With increased dust in the ambient air, clean the Peltier fan grid by suction or blowing several times a year. A clogged grid reduces heat rejection and can degrade cooling capacity or trigger overtemperature conditions. The service reminder displays remaining days until maintenance when OK is held for 5 seconds.
IP protection is 20 per EN 60529, meaning no water protection. The chamber must be set up splash-proof and must not become wet during operation, cleaning or maintenance; cleaning and decontamination must follow the manual's procedures to avoid ingress into electrical and Peltier components.
Selection & Integration Q&A
Pick the 1020 when you need the series' largest capacity: 1,020 L interior, 973 mm interior width and 150 kg permitted load. The 240/400/720 share the 0–70 °C range but offer smaller chambers; choose them when floor space or sample volume is lower. Note the 1020's 327 kg empty weight and 1,250 mm net width for site access.
The 230 V variant needs 200–230 V 1~ 50/60 Hz sized for 5.8 A (1.3 kW) with a CEE 7/7 plug; the UL variant needs 100–120 V sized for 7.5 A (0.9 kW) with NEMA 5-20. For multi-chamber monitoring, plan Ethernet addressing and chamber addresses for APT-COM™ 4, which networks up to 100 chambers.
Maintain 100 mm clearance at the back and sides and never install in an unventilated recess; the IP 20 enclosure must stay dry. Do not exceed 150 kg total load or 45 kg per rack, and respect the 500 W maximum heat compensation. The chamber is not for explosive areas or medical-device sterilization.
Plan annual maintenance by BINDER-authorized personnel plus annual electrical repeat inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702. Clean the Peltier fan grid several times a year in dusty air; replace the door gasket only when cold. APT-COM™ 4 software and USB sticks for data transfer are accessories, not included.