BINDER KB ECO 400
BINDER KB ECO 400 — Incubators with Temperature 0…70 °C.
The KB ECO 400 is a 400 L thermoelectric cooling incubator (Peltier technology) with a 0–70 °C working range, part of the KB ECO series alongside the 240, 720 and 1020 sizes. Its 650 mm interior width and 120 kg permitted load distinguish this mid-size modification, which is intended for refrigerated incubation and long-term storage of microorganisms at 4–37 °C in laboratory systems.
Direct drop-in replacements
BINDER KB ECO Series — Model Comparison & Selection
| Model | Temperature, °C | Depth, cm | Height, cm | Interior volume, L | Interior width, mm | Load per rack, kg |
|---|---|---|---|---|---|---|
| KB ECO 400 Current | 0–70 | 79.6 | 194.6 | 400 | 650 | 30 |
| KB ECO 1020 | 0–70 | 114.9 | 192.5 | 1020 | 973 | 45 |
| KB ECO 240 | 0–70 | 79.6 | 146.1 | 247 | 650 | 30 |
| KB ECO 720 | 0–70 | 88.5 | 192.5 | 700 | 973 | 45 |
Full specifications
| Temperature | 0...70 °C |
| Interior volume | 400 L |
| Load per rack | 30 kg |
| Max. heat compensation | 350 W |
| Nominal power | 1.2 kW |
| Permitted load | 120 kg (KBECO400-230V / KBECO400-120V) |
| Temperature fluctuation | 0.1 K |
| Temperature uniformity | 0.1 K |
| Back wall clearance | 100 mm (KBECO400-230V / KBECO400-120V) |
| Side wall clearance | 100 mm (KBECO400-230V / KBECO400-120V) |
| Article Number mfr | 9020 |
| Recovery time after door was opened for 30 s at 37°C mfr | 6 min |
| Depth | 796 mm (KBECO400-230V / KBECO400-120V) |
| Height | 1946 mm (KBECO400-230V / KBECO400-120V) |
| Interior width | 650 mm (KBECO400-230V / KBECO400-120V) |
| Width | 925 mm (KBECO400-230V / KBECO400-120V) |
| Net weight of the unit (empty) mfr | 196 kg |
| Power frequency | 50 Hz |
| Rated voltage | 200...230 V |
| Unit fuse | 16.0 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The KB ECO 400 uses Peltier (thermoelectric) cooling rather than a compressor circuit, with a 400 L interior volume and net dimensions of 925 mm wide × 796 mm deep × 1,946 mm high.
- Within the KB ECO series it sits between the 240 and 720 models; all share the 0–70 °C range, but the 400 is the size that requires the flexible tilt protection kit (chap. 4.2) and offers a 120 kg permitted load with 30 kg per rack.
- The chamber is rated IP 20 (EN 60529) and is not protected against water ingress.
Thermal behaviour and load
- Temperature fluctuation and uniformity are both specified at 0.1 K, supported by a 350 W maximum heat compensation and 1.2 kW nominal power.
- Recovery time after a 30 s door opening at 37 °C is 6 min, which matters for frequent-access incubation protocols.
- The intended application range for microorganism cultivation is 4 °C to 37 °C, covering long-term storage at 4 °C, refrigerated incubation at 20–25 °C, incubation at 37 °C, and alternating temperature programs.
Control, installation and operation
- Control is via the RD4 chamber controller, which provides automatic setpoint switchover (date- or cycle-based), Idle mode, tolerance-range alarms, a data recorder (DL1) and Ethernet networking.
- Temperature safety is provided by an over-temperature protective device (class 1) and an overtemperature safety controller class 3.1 per DIN 12880:2007, which must be configured and function-checked.
- Installation requires 100 mm clearance at the back and sides, and the chamber must not be placed in unventilated recesses; a condensate collection pan and wall spacers are part of the installation scope.
Integration & Operating Notes
The KB ECO 400 must be fitted with the flexible tilt protection kit described in chapter 4.2 before operation; omitting it leaves the tall 1,946 mm cabinet without the prescribed anti-tilt safeguard, which is a safety-relevant installation defect.
The chamber needs 100 mm wall clearance at the back and sides and must not be installed in unventilated recesses; the Peltier cooling rejects heat to the ambient air, so restricted airflow causes overheating and loss of cooling performance.
The 230 V variant draws 5.8 A at 200–230 V/50 Hz (1.2 kW nominal, 16 A unit fuse), while the UL 120 V variant draws 7.5 A at 100–120 V; the branch circuit, plug type (CEE 7/7 vs NEMA 5-20) and protective device must match the ordered variant.
The overtemperature safety controller class 3.1 per DIN 12880:2007 must be set to the correct mode and value and function-checked before routine use; an unconfigured safety controller will not protect the load if the RD4 setpoint or sensor fails.
Loading material must not contain acids or halides that attack stainless steel, aluminum or copper, and the chamber must not be used in explosive atmospheres or with combustible substances; such use voids BINDER liability and can damage the Peltier heat exchangers.
Maintenance must be performed at least once a year by licensed electricians or BINDER-authorized experts, with an annual electrical repeat inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702; the controller's Service Reminder shows days remaining and displays 'Service due!' after one year.
With increased dust in the ambient air, the Peltier fan grid must be cleaned by suction or blowing several times a year; a clogged grid reduces heat rejection and can cause the chamber to lose cooling capacity or overheat.
Selection & Integration Q&A
Pick the 400 when 400 L interior volume and a 120 kg permitted load (30 kg per rack) fit your batch, since all KB ECO sizes share the 0–70 °C range and 0.1 K uniformity. The 240 suits smaller loads; the 720 and 1020 are for larger batches but need more floor space and the same 100 mm clearances.
The 230 V variant (Art. 9020-0465) needs 200–230 V/50 Hz, draws 5.8 A at 1.2 kW nominal and uses a CEE 7/7 plug with a 16 A unit fuse. The UL 120 V variant (Art. 9020-0466) needs 100–120 V, draws 7.5 A and uses a NEMA 5-20 plug; size the branch circuit accordingly.
It must stand with 100 mm clearance at the back and sides, never in an unventilated recess, and the flexible tilt protection kit for size 400 must be mounted. IP 20 means no water exposure, and explosive atmospheres or corrosive loads (acids, halides) are prohibited.
Annual maintenance by BINDER-authorized personnel and an annual electrical repeat inspection are mandatory; the Service Reminder tracks the one-year interval. The Peltier fan grid needs cleaning several times a year in dusty air. APT-COM™ 4 software (up to 100 chambers) and the DL1 data recorder functions are separate accessories/options.