Elmo Rietschle C-VLR 401
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle C-VLR 401

Elmo Rietschle C-VLR 401 — Claw Vacuum Pumps.

The C-VLR 401 is a contact-free running claw vacuum pump with a double-shaft dry rotary piston design, gearbox oil lubrication, and an integral frequency converter for infinitely variable speed. It delivers 380 m³/h at 50 Hz free intake and operates continuously between 700 mbar (abs.) and 200 mbar (abs.) inlet pressure, distinguishing it from smaller siblings like the C-VLR 301 (290 m³/h) and larger C-VLR 501 (495 m³/h). It is intended for dry, non-aggressive gas evacuation in industrial vacuum systems where oil-free compression and variable speed control are required.

Elmo Rietschle C-VLR Series — Model Comparison & Selection

Model Operating principleNoise level, dBWeight, kgMotor power, kWPumping speed, m³/hUltimate pressure, mbar
C-VLR 401 Current contact free running cla79470———
C-VLR 1000 claw8275718.5950200
C-VLR 150 Claw—————
C-VLR 301 claw742855.5290150
C-VLR 60 —7847———
C-VLR 62 ——————

Full specifications

Core Performance & Functional Specifications
Operating principle contact free running claw vacuum pump
Condensate drain silencer mfr G 1⁄2
Dimensions, Weight & Mechanical Design
Height 963 mm
Length 1169 mm
Weight 470 kg
Width 598 mm
Interfaces, Connections & Control
Inlet flange G 3
Outlet flange G 3
Materials, Media & Process Compatibility
Oil capacity 1.75 l
Operating Conditions, Environment & Protection
Noise level 79 dB
50 Hz: 79 dB · 60 Hz: 82 dB
Sound pressure level (max.) 60 Hz (alt var) mfr 82 dB

Description

Construction and series positioning

Behavior under load and media

Installation, connection, and control

Integration & Operating Notes

Process Limits
Continuous operation only between 700 and 200 mbar (abs.)

Operating outside this inlet pressure band may be considered outside designated use and can lead to overheating or mechanical damage. Ensure process control keeps the pump within this range during all phases, including start-up and shutdown.

Operating Instructions BA 886-70-FU, Section 4.3, p.14
Process Limits
Closed-system volume must not exceed 2% of nominal capacity

When evacuating a closed system, the volume to be evacuated must be no more than 2% of the pump's nominal suction capacity (380 m³/h at 50 Hz). Larger volumes can cause excessive evacuation times or pump overload; size reservoirs or connected volumes accordingly.

Operating Instructions BA 886-70-FU, Section 4.3, p.14
Mounting
Install horizontally with max. 8° inclination in all directions

The machine must be set up on a level, straight foundation able to take its weight (470 kg). Inclination beyond 8° can impair lubrication and cause premature wear. Secure against tipping and falling, and provide at least 50 cm maintenance space and 30 cm clearance for cooling air.

Operating Instructions BA 886-EN, Section 5.2, p.17
Electrical
Verify motor rotation direction before commissioning

The motor fan must rotate counter-clockwise when viewed from the fan. Use a phase sequence indicator to verify the clockwise rotating field and perform a brief start (max. 2 seconds). Wrong rotation direction can damage the machine and cause injury.

Operating Instructions BA 886-70-FU, Section 6.1.1, p.19
Electrical
Direct-on-line starting prohibited for motors above 5.2 kVA

For three-phase motors with apparent power above 5.2 kVA or starting current above 60 A, direct-on-line starting is not permitted. Use star-delta starter, soft starter, or frequency inverter to reduce mechanical and electrical load during start-up.

Operating Instructions BA 886-NL, Section 5.5.1, p.19
Process Limits
Exhaust back pressure must not exceed +50 mbar

The exhaust line must be sized and routed to avoid exceeding +50 mbar back pressure. Do not install shut-off devices or restrictions in the discharge line; check exhaust pipe regularly for impurities. Higher back pressure requires manufacturer consultation.

Operating Instructions BA 886-EN, Sections 2.4 and 5.3, p.8 and p.18
Maintenance
Oil change every 20,000 h with approved ISO VG 150 oil

Use only Elmo Rietschle approved oils (GEAR-LUBE 150 or ECO-GEAR-LUBE 150) to maintain the 20,000-hour oil change interval. Extreme conditions can reduce oil life to 5,000 hours. Oil quantity is 1.75 l; fill to middle of sight glass.

Operating Instructions BA 886-NL, Section 7.1 and 7.2, p.23-24
Maintenance
Check coupling sprocket at least annually

A defective coupling sprocket may lead to rotor shaft breakage. Inspect the coupling gear rim and fan at least once a year; replace if worn or damaged. Motor flange screws must be tightened to 84 Nm after refitting.

Operating Instructions BA 886-70-FU, Section 7.2.3, p.24
Process Limits
Ambient and intake temperatures must remain within limits

Operation outside this range requires consultation with the manufacturer. Ensure installation room ventilation and cooling air supply keep both ambient and intake temperatures within limits; cooling air must not be recirculated.

Operating Instructions BA 886-EN, Section 4.2, p.15

Selection & Integration Q&A

When should I choose the C-VLR 401 over the C-VLR 301 or C-VLR 501?

Choose the 401 for 380 m³/h at 50 Hz and continuous operation between 700 and 200 mbar (abs.). The 301 offers 290 m³/h and 5.5 kW for lower flows; the 501 provides 495 m³/h for higher capacity. The 401 balances medium duty with the same G 3 connections and 470 kg weight class as the 501.

What are the requirements for the electrical supply and motor starting of the C-VLR 401?

For the VSD version, the frequency converter input is 3 AC 400 V –15% to 480 V +10%, 47–63 Hz, TN/TT networks. Direct-on-line starting is not permitted for motors above 5.2 kVA or starting current >60 A; use star-delta, soft starter, or frequency inverter. For the standard motor variant, consult the manufacturer for specific supply tolerances.

What are the mounting and environmental limits for installing the C-VLR 401?

Install horizontally on a level foundation with max. 8° inclination in all directions. Provide at least 50 cm maintenance space and 30 cm clearance for cooling air inlets/outlets. Ambient and suction temperatures must be 5–40 °C; above 1000 m altitude, consult manufacturer for derating.

What maintenance items and accessories are not included in the base delivery of the C-VLR 401?

The base delivery excludes pressure monitoring (required for the OXY variant, which is not further defined in this document), suction filter cartridge (accessory, replace every 6 months), and condensate drain silencer (G ½) for XD. Spare parts like coupling star ZS1183380 and mesh filter ZS1114498 are available separately. Oil must be ordered separately: GEAR-LUBE 150 (1 l dose 7201706000).

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — C-VLR 401 vacuum pump (BA 886-70-FU, EN)
Manual ·2,8 МБ ·30 pp.
View PDF
PDF
Operating Instructions — C-VLR 401 vacuum pump (BA 886-EN, ed. 1.1 12.04.2021, EN)
Manual ·1,8 МБ ·34 pp.
View PDF
PDF
Operating Instructions — C-VLR 401 (BA 886-NL, NL)
Manual ·2,6 МБ ·34 pp.
View PDF
PDF
Operating Instructions — C-VLR 401 OXY vacuum pump (BA 886-OXY, ed. 1.0 12.10.2023, EN)
Manual ·2,8 МБ ·34 pp.
View PDF
PDF
Spare Parts List — C-VLR 401 (E 886, EN)
Spare parts ·262,6 КБ ·2 pp.
View PDF