Operating Instructions — C-VLR 150 vacuum pump (BA 880-EN, ed. 1.3 14.09.2023, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the contact-free running claw vacuum pumps C-VLR 150 and C-VLR 251, including the C-VLR 251 (15) variant with intake filter valve and the XD version with corrosion-protective coating for humid gases. Standard version CD is for dry, non-aggressive gases. Document edition 1.3, 14.09.2023, BA 880-EN.

Section-by-Section Technical Breakdown

pp. 14-18
Product Overview and Functioning

Describes the C-VLR 150, C-VLR 251 and C-VLR 251 (15) pump layouts, component identification, data plate contents and operating principle. The pump is a double-shaft rotary piston vacuum pump with contact-free dry-running claw rotors synchronised by an oil-lubricated gear pair; the feed chamber has no sealants or lubricants. Cooling is by a drum fan drawing air between the machine and its insulation hood.

  • Component callouts include vacuum connection A, exhaust air outlet B, vacuum control valve C, cooling air inlet E, cooling air outlet F, oil filling point H, oil sight glass I, oil discharge point K, data plate N, rotation direction plate O, drive motor P, hot surfaces >70 °C Q, terminal box S1, exhaust silencer Z.
  • C-VLR 251 (15) additionally has S2 intake filter valve.
  • Data plate encodes type/size, serial number, year of construction, data matrix barcode, article number, speed, motor output, operating mode, suction capacity and final pressure (abs.).
  • Barcode encodes material number (MA), production order (PR) and serial number (SC).
  • Gearbox and compression chamber are separated by special seals; an atmospherically ventilated area between them can be loaded with sealing gas in special version.
  • Drive is via standard flanged three-phase motor and coupling with elastomer component.
pp. 18
Fields of Application

Defines the continuous operating pressure range and suction capacity for each model. The pumps can run continuously at any pressure between atmosphere and the stated minimum inlet pressure. The XD design is suitable for water-damp gases.

  • Continuous operation possible down to 60 mbar (abs.) for C-VLR 150 / 150 (31).
  • Continuous operation possible down to 100 mbar (abs.) for C-VLR 150.
  • Continuous operation possible down to 200 mbar (abs.) for C-VLR 251.
  • Suction capacity with unrestricted suction is 150 m3/h and 215 m3/h at 50 Hz.
  • Frequent switching at about 12 times/h (C-VLR 150) or 10 times/h (C-VLR 251) at higher ambient and intake temperatures may exceed motor winding and bearing excess temperature limits; contact manufacturer.
  • Outdoor installation requires protection from environmental influences, e.g. a protective roof.
pp. 19-22
Installation

Covers preparation, mechanical installation, pipe connection, vacuum control/relief valve, oil level check and electrical connection. The machine must be installed horizontally with maximum inclination 8° in all directions, with sufficient cooling-air clearance and accessible oil points. Electrical connection must be made by a qualified electrician according to EN 60204 with motor protection switch.

  • Machine freely accessible from all sides; ventilation grids and holes must not be closed.
  • Provide at least 40 cm space before the intake silencer for maintenance.
  • Maximum inclination 8° in all directions; secure against tipping and falling.
  • Ambient temperature min. +5 °C, max. +40 °C.
  • Cooling air inlets and outlets at least 30 cm from adjacent walls; exhaust cooling air must not be re-sucked.
  • Maximum permissible back pressure +30 mbar; exhaust air openings must never be closed or constricted.
  • Only screw in pipes by hand; use flexible connections or compensators if necessary.
  • Operation without the standard control and relief valve is forbidden.
  • Oil level must be at the middle of the sight glass.
  • Electrical supply tolerances: ±5 % voltage deviation, ±2 % frequency deviation.
  • Motor protection class IP 55, insulation class F, complying with DIN EN 60034.
  • Motor must be safeguarded by a motor protection switch installed by the operating company; main switch provided by user.
pp. 23-25
Commissioning and Decommissioning

Describes start-up checks, rotation direction verification, operation including condensate draining, and shutdown/storage/recommissioning. The installation check covers mechanical, piping, electrical and oil conditions. Rotation direction must be checked briefly and must be counter-clockwise when viewing the motor blower.

  • Installation check includes transport/assembly damage, stable horizontal stand, correct and leak-tight pipe connection, tight screw/flange connections, electrical compliance, adequate room ventilation, oil level, cleanliness and function of optional accessories.
  • Check rotation direction with phase sequence indicator; brief start max. two seconds; when looking at motor blower it must rotate counter-clockwise.
  • Keep a distance of 1 m to outlet and inlet connections during rotation check.
  • Machine may only be switched on again after it stands still.
  • Before shutdown for more than 2 hours or decommissioning, run the pump at 700 mbar (abs.) for at least 15–30 minutes with dry air to remove moisture and pollution.
  • XD model: regularly discharge condensate from the silencer through the condensate drain; wear protective gloves and allow cooling before draining.
  • Disconnect from power supply via main switch or plug and secure against unexpected restart before electrical work.
pp. 26-33
Maintenance and Repair

Covers maintenance tasks including cleaning the vacuum pump and vacuum control valve, oil level check and oil change, air filtering (micro filter and intake filter), motor and coupling checks, repair/service and spare parts. Maintenance must ensure operational safety and use only approved spare parts.

  • Oil change and suitable oil types are specified in chapter 7.6.
  • Vacuum control valve must be cleaned or replaced if dirty and permissible vacuum exceeded.
  • Intake filter must be cleaned or replaced when suction capacity is insufficient.
  • Spare parts are listed in spare parts document E 880.
  • Repairs only by authorised workshops using original spare parts.
pp. 35-36
Errors

Contains a table of malfunctions with causes and elimination measures. It covers motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating, strange noise and control valve vibration. The manual warns never to restart an automatically stopped pump without finding and remedying the cause.

  • Malfunction table includes signs, causes, elimination and reference chapters.
  • Motor protection switch may trip due to incorrect mains voltage/frequency, incorrect motor terminal connection, incorrect switch setting, or too-fast trip; use overload-dependent delayed switch per VDE 0660 Part 102 or IEC 60947-4-1.
  • Insufficient suction capacity can be caused by dirty intake filter, too long/narrow inlet pipe, or leaking machine/system.
  • Final pressure not reached is attributed to machine or system leakage.
  • Overheating can be caused by high ambient/inlet temperature, obstructed cooling air supply, or dirty control valve.
  • Strange noise can be caused by deposits on rotary piston or vibrating control valve.
  • Contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.
pp. 38
Technical Data

The manual references chapter 10 for technical data such as weight, sound pressure level and electrical data. Detailed values are provided in data sheet D 880 / D 880-31 rather than in the body text of this manual.

  • Technical data chapter is on page 38.
  • Data sheet D 880 / D 880-31 contains technical data and characteristic curves.
  • Sound pressure level is measured as per EN ISO 3744 and stated in chapter 10.
  • Bearing surface must be designed to carry the machine weight; see chapter 10.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ambient and inlet temperature must be between 5 and 40 °C. p.8 ↗ Operation outside this range requires consultation with the manufacturer; otherwise overheating or damage may occur. C-VLR 150 and C-VLR 251
Maximum permissible back pressure is +30 mbar. p.8 ↗ Exhaust lines must be sized and routed to avoid exceeding this limit; blocking devices must not be installed. C-VLR 150 and C-VLR 251
Continuous operation is possible down to 60 mbar (abs.) for C-VLR 150 / 150 (31), 100 mbar (abs.) for C-VLR 150, and 200 mbar (abs.) for C-VLR 251. p.18 ↗ Select the model according to the required continuous inlet pressure; lower pressures may only be reached intermittently. C-VLR 150, C-VLR 150 (31), C-VLR 251
Suction capacity with unrestricted suction is 150 m3/h and 215 m3/h at 50 Hz. p.18 ↗ Use data sheet D 880 or D 880-31 for suction capacity dependence on inlet pressure. C-VLR 150 and C-VLR 251
Maximum installation inclination is 8° in all directions; machine must be set up horizontally. p.19 ↗ Mounting surface must be plane and even; secure against tipping and falling. C-VLR 150 and C-VLR 251
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.19 ↗ Ensure good aeration and venting of the installation room; exhausted cooling air must not be re-sucked. C-VLR 150 and C-VLR 251
Provide at least 40 cm space before the intake silencer for maintenance work. p.19 ↗ Installation layout must allow access for maintenance and removal of the intake silencer. C-VLR 150 and C-VLR 251
Permissible voltage deviation is ±5 % and frequency deviation is ±2 %. p.21 ↗ Verify mains conditions against motor data plate before connection; incorrect supply can cause loss of power or damage. C-VLR 150 and C-VLR 251
Motors comply with DIN EN 60034, protection class IP 55 and insulation class F. p.21 ↗ Electrical installation must be suitable for IP 55 environment and class F insulation. C-VLR 150 and C-VLR 251
Motor must be safeguarded by a motor protection switch; main switch must be provided by the user. p.21 ↗ The operating company must install a motor protection switch and main switch; electrical installation by qualified electrician per EN 60204. C-VLR 150 and C-VLR 251
Use a motor protection switch with overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1). p.35 ↗ Prevents nuisance tripping during cold starts. C-VLR 150 and C-VLR 251
Check rotation direction by briefly starting the motor for max. two seconds; when looking at the motor blower, it must rotate counter-clockwise. p.24 ↗ Wrong rotation direction can damage the machine and cause injury; use a phase sequence indicator. C-VLR 150 and C-VLR 251
Before shutdown for more than 2 hours or decommissioning, run the pump at 700 mbar (abs.) for at least 15–30 minutes with dry air. p.25 ↗ Removes moisture and pollution to prevent deposits and start-up problems. C-VLR 150 and C-VLR 251
Oil level must be at the middle of the oil sight glass. p.21 ↗ Check oil level through sight glass and top up at oil filling point if necessary. C-VLR 150 and C-VLR 251
Operation without the standard vacuum control and relief valve is forbidden. p.21 ↗ The control valve must remain installed; it pre-sets vacuum and serves as relief valve. C-VLR 150 and C-VLR 251
Long connecting lines of more than 3 m can cause reverse rotation after the machine is switched off. p.20 ↗ Install a non-return valve (ZRK accessory) to protect the machine. C-VLR 150 and C-VLR 251
An output reduction is noticeable when installed at more than 1000 m above sea level. p.20 ↗ Contact manufacturer for installation at altitudes above 1000 m. C-VLR 150 and C-VLR 251
Frequent switching at about 12 times/h (C-VLR 150) or 10 times/h (C-VLR 251) at higher ambient and intake temperatures may exceed motor winding and bearing excess temperature limits. p.18 ↗ Contact manufacturer for such operating conditions. C-VLR 150 and C-VLR 251
Storage temperature range is -10 °C to +60 °C; relative air humidity max. 80 %; storage not more than 6 months. p.13 ↗ Store dust-free, dry, vibration-free and protected from sun radiation; close openings air-tight. C-VLR 150 and C-VLR 251
Surface temperatures on components may rise above 70 °C during operation. p.23 ↗ Do not touch hot surfaces; wear suitable protective gloves if necessary. C-VLR 150 and C-VLR 251

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.35 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Chapter 5.6
Machine is switched off by the motor protection switch p.35 ↗ Connection to motor terminal board is not correct Check by qualified electrician Chapter 5.6
Machine is switched off by the motor protection switch p.35 ↗ Motor protection switch is not set correctly Check by qualified electrician Chapter 5.6
Machine is switched off by the motor protection switch p.35 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Machine is switched off by the motor protection switch p.35 ↗ The control valve is dirty so that the permissible vacuum value is exceeded Clean/replace the vacuum control valve Chapter 7.5, Chapter 7.10
Suction capacity is insufficient p.35 ↗ The intake filter is dirty Clean / replace the intake filter Chapter 7.7, Chapter 7.10
Suction capacity is insufficient p.35 ↗ The inlet pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Suction capacity is insufficient p.35 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Final pressure (max. vacuum) is not reached p.35 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Machine gets too hot p.35 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Machine gets too hot p.35 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.35 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.2
Machine gets too hot (continued) p.35 ↗ The control valve is dirty so that the permissible vacuum value is exceeded Clean/replace the vacuum control valve Chapter 7.5, Chapter 7.10
The machine makes a strange noise p.36 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service
The machine makes a strange noise p.36 ↗ The control valve is vibrating Replace the valve Chapter 7.10