Operating Instructions — C-VLR 62 (BA 882-31-AC, ed. 1.1 17.01.2022, IT)
Technical Reference Summary
Covered Models & Document Scope
This manual covers the C-VLR 62 and C-VLR 122 contact-free rotary claw vacuum pumps, in standard (CD) and corrosion-protected (XD) versions, with and without frequency converter. It includes active cooling variants and accessories such as suction filter and vacuum limiting valve.
Section-by-Section Technical Breakdown
Describes the C-VLR 62 and C-VLR 122 pump construction, including connections, oil fill, condensation drain (XD only), and the frequency-converter version. Explains the contact-free rotary claw operating principle and typical fields of application.
- Vacuum connection G 1 1/2
- Discharge outlet G 1 1/2
- Suction flange with non-return valve
- Oil fill and oil type plate
- Condensate drain only on XD version
- Frequency-converter version includes cooling air inlet, oil sight glass, oil drain, and blower silencer
Covers preparation, positioning, pipe connection, and checking lubricating oil before commissioning. Ensures proper installation and oil level prior to electrical connection.
- Prepare installation site
- Position the pump
- Connect piping
- Check lubricating oil level
Details connecting the motor for machines without a frequency converter and for machines with a frequency converter. Includes supply connection requirements.
- Motor connection without frequency converter
- Motor connection with frequency converter
Describes installation checks, rotation direction verification, normal operation, condensate draining, shutdown, storage, and recommissioning.
- Check installation before start-up
- Verify direction of rotation
- Drain condensate during operation
- Stop and store the machine
- Recommissioning procedure
Provides maintenance schedule and procedures for cleaning the vacuum pump, checking and changing lubricating oil, servicing air filters, motor and coupling, frequency converter, and ordering spare parts.
- Maintenance table
- Clean vacuum pump
- Check and top up oil level
- Change oil
- Clean mesh filter and suction filter
- Motor and coupling maintenance
- Frequency converter maintenance
- Spare parts ordering via list E 882-31
Lists technical specifications for variants without and with frequency converter, including frequency, ultimate pressure, pumping speed, speed, motor power, and voltage.
- Variants without frequency converter
- Variants with frequency converter
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Vacuum connection and discharge outlet are both G 1 1/2. p.14 ↗ | Piping must be sized to G 1 1/2 to match pump ports. | C-VLR 62 and C-VLR 122 |
| Condensate drain is only present on the XD (corrosion-protected) version. p.14 ↗ | XD variants require routing of condensate drain; CD variants do not have this drain. | XD variants |
| Frequency-converter version includes a cooling air inlet, oil sight glass, oil drain, and blower silencer. p.16 ↗ | Installation must provide cooling air access and allow oil inspection/draining. | Variants with frequency converter |
| Maximum suction capacity is 62 m³/h or 120 m³/h at 50 Hz. p.18 ↗ | Select piping and system components for at least these flow rates. | C-VLR 62 and C-VLR 122 |
| Data plate indicates frequency range 20–60 Hz, ultimate pressure 150–100 mbar(abs.), pumping speed 44–135 m³/h, speed 1220–3590 rpm, motor power 1.05–2.9 kW. p.17 ↗ | Verify application requirements fall within these ranges when selecting a variant. | C-VLR series |
| Spare parts must be ordered using spare parts list E 882-31 for C-VLR 62 | 122 active cooling. p.33 ↗ | Use only original or manufacturer-approved spare parts to maintain warranty and liability. | C-VLR 62 and C-VLR 122 |
| Wear parts and seals are listed separately in the spare parts list. p.33 ↗ | Include wear parts and seals in maintenance planning and spare parts inventory. | C-VLR 62 and C-VLR 122 |
| The machine is a ready-to-connect combination of vacuum pump and motor. p.5 ↗ | No separate motor-pump assembly is required at installation. | C-VLR series |
| CD designates standard version; XD designates corrosion-protected version. p.5 ↗ | Choose XD for corrosive gas duty; CD for standard applications. | C-VLR series |
| Final pressure (suction) is the maximum vacuum a pump reaches with suction opening closed. p.5 ↗ | Use this value to assess achievable ultimate vacuum for the application. | C-VLR series |