Operating Instructions — C-VLR 401 vacuum pump (BA 886-EN, ed. 1.1 12.04.2021, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the contact-free running claw vacuum pumps C-VLR 401 and C-VLR 501 (C-Series), including standard design CD and corrosion-protective design XD. Document BA 886-EN, edition 1.1, 12.04.2021.

Section-by-Section Technical Breakdown

pp. 14-15
Product Overview and Functioning

Describes the C-VLR 401 and C-VLR 501 as double-shaft rotary piston vacuum pumps with contact-free, dry-running claw rotors synchronised by an oil-lubricated gear pair. The gearbox and compression chamber are separated by special seals; the pump has an inlet flange, exhaust silencer, mesh intake filter, integral non-return valve and vacuum relief valve. Cooling is by a drum fan drawing air between compressor and insulation hood.

  • Double-shaft rotary piston (claw) design, contact-free and dry running
  • Gear pair in oil-filled gearbox synchronises counter-rotating rotors
  • Integral non-return valve prevents ventilation of evacuated system after stop
  • Vacuum relief valve incorporated into the machine
  • Insulation hood with drum fan for cooling air; driven via coupling by flanged three-phase standard motor
  • XD model has corrosion-protective coating and condensate drain (Fig. 2/B2)
pp. 16
Fields of Application

Defines continuous operation between 700 mbar (abs.) and an inlet pressure of 200 mbar (abs.). For evacuating closed systems, the volume must not exceed 2% of nominal pumping capacity. Free intake pumping capacity is 380 m3/h and 495 m3/h at 50 Hz. XD design is suitable for water-damp gases (water vapour).

  • Continuous operation at any pressure between 700 mbar (abs.) and 200 mbar (abs.) inlet pressure
  • Closed-system volume to be evacuated ≤ 2% of nominal pumping capacity
  • Free intake pumping capacity: 380 m3/h (C-VLR 401) and 495 m3/h (C-VLR 501) at 50 Hz
  • XD design suitable for conveying water-damp gases (water vapour)
  • Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits — contact manufacturer
  • Outdoor installation requires protection from environmental influences (e.g. protective roof)
pp. 17-19
Installation

Covers preparation, mechanical installation, pipe connection, oil check and electrical connection. The machine must be installed horizontally with max. 8° inclination in all directions, with at least 50 cm maintenance space and 30 cm clearance from walls for cooling air. Electrical installation must be by a qualified electrician per EN 60204, with motor protection switch and main switch provided by the user.

  • Max. inclination 8° in all directions; floor must be plane and even
  • Maintenance space at least 50 cm around machine
  • Cooling air inlets/outlets at least 30 cm from adjacent walls; exhaust air must not be re-sucked
  • Ambient temperature min. +5 °C, max. +40 °C
  • Maximum permissible back pressure +50 mbar; exhaust air opening must not be closed or restricted
  • Only screw in pipes by hand; use flexible connections/compensators if necessary
  • Oil level filled to middle of sight glass
  • Electrical installation per EN 60204 by qualified electrician; main switch and motor protection switch provided by user
  • Permissible tolerances: ±5% voltage deviation, ±2% frequency deviation
  • Motor protection class IP 55, insulation class F, per DIN EN 60034
pp. 20-22
Commissioning and Decommissioning

Start-up requires an installation check and rotation direction check. The motor must rotate counter-clockwise when viewed at the motor blower; use a phase sequence indicator and keep 1 m distance from inlet/outlet. Before decommissioning or shutdown >2 hours, run the pump at 700 mbar (abs.) with dry air for 15–30 minutes to remove moisture and pollution.

  • Installation check: no transport damage, horizontal safe standing, leak-tight pipe connections, tight screw/flange connections, correct electrical installation, adequate ventilation, oil filled and level checked, pump and pipelines cleaned
  • Check rotation direction with phase sequence indicator; brief start max. 2 seconds; motor blower must rotate counter-clockwise
  • Keep 1 m distance from outlet and inlet connections during rotation check
  • Before shutdown >2 hours or decommissioning: run at 700 mbar (abs.) with dry air for at least 15–30 minutes
  • XD model: regularly discharge condensate from silencer through condensate drain; wear protective gloves
  • Decommissioning: drain condensate, switch off, allow to cool, close cut-off devices, disconnect power, depressurise slowly, remove pipes, seal connections with adhesive foil
pp. 23-29
Maintenance and Repair

Maintenance includes cleaning the vacuum pump, checking/refilling lubricating oil, oil change, cleaning/replacing air filters (mesh filter and optional intake filter), and motor/coupling checks. Cleaning and oil change intervals depend on load and oil type. Repair works only by authorised specialists; spare parts per list E 886.

  • Disconnect power and secure against accidental switching before maintenance
  • Allow machine to cool down before maintenance; surfaces may exceed 70 °C
  • Safety devices and guards on motor fans and ventilators must not be removed
  • Cleaning and oil change intervals depend on operating time, operating conditions and oil type
  • Oil change and suitable oil types per chapter 7.5.2
  • Air filter: clean/replace mesh filter; intake filter is an accessory
  • Repair works only by authorised specialists; use original spare parts
pp. 30
Errors

Troubleshooting table covering motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating and strange noise. Lists causes and remedies with references to relevant chapters. Contact Elmo Rietschle Service for other malfunctions.

  • Never restart pump after automatic shut-off without finding and remedying the cause
  • Motor protection switch must have overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1)
  • Insufficient suction capacity causes: polluted air filter, inlet pipe too long/narrow, leaking machine/system
  • Final pressure not reached causes: leaking machine/system, polluted air filter
  • Overheating causes: ambient/inlet temperatures too high, obstructed cooling air supply
  • Strange noise cause: deposits on rotary piston — clean working space and rotary piston
pp. 32
Technical Data

Technical data chapter referenced for weight, sound pressure level and other performance data. Specific values are provided in data sheet D 890.

  • Technical data per chapter 10 and data sheet D 890
  • Sound pressure level per EN ISO 3744
  • Weight and bearing surface load per chapter 10

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Continuous operation permitted at any pressure between 700 mbar (abs.) and an inlet pressure of 200 mbar (abs.). p.16 ↗ Select pump for applications within this inlet pressure range; operation outside requires consultation with manufacturer. C-VLR 401 and C-VLR 501
When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity of the vacuum pump. p.16 ↗ Size closed-system evacuation volumes accordingly to avoid excessive evacuation times or pump overload. C-VLR 401 and C-VLR 501
Free intake pumping capacity is 380 m3/h (C-VLR 401) and 495 m3/h (C-VLR 501) at 50 Hz. p.16 ↗ Use these values for initial sizing; actual capacity depends on intake pressure per data sheet D 890. C-VLR 401 and C-VLR 501
Maximum permissible back pressure is +50 mbar. p.8 ↗ Exhaust lines must be sized and routed to avoid exceeding +50 mbar back pressure; do not install blocking devices. C-VLR 401 and C-VLR 501
Ambient and inlet temperature must be between 5 °C and 40 °C. p.8 ↗ Ensure installation room ventilation and process conditions stay within this range; contact manufacturer for temperatures outside range. C-VLR 401 and C-VLR 501
Machine may only be operated horizontally with max. inclination 8° in all directions. p.17 ↗ Mount on a plane, even floor; secure against tipping and falling. C-VLR 401 and C-VLR 501
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; cooling air coming out must not be sucked in again. p.17 ↗ Maintain clearance for adequate cooling and prevent hot air recirculation to avoid overheating. C-VLR 401 and C-VLR 501
For maintenance works, provide for a space of at least 50 cm around the machine. p.17 ↗ Plan installation layout with sufficient access for maintenance and pipe removal. C-VLR 401 and C-VLR 501
Permissible voltage deviation ±5%, frequency deviation ±2%. p.19 ↗ Verify mains supply quality at installation location against motor data plate before connection. C-VLR 401 and C-VLR 501
Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.19 ↗ Suitable for dusty and damp environments per IP 55; verify environmental conditions. C-VLR 401 and C-VLR 501
Motor must rotate counter-clockwise when viewed at the motor blower; check with phase sequence indicator and brief start max. 2 seconds. p.21 ↗ Wrong rotation direction can damage machine and cause injury; verify before commissioning. C-VLR 401 and C-VLR 501
Before shutdown >2 hours or decommissioning, run pump at 700 mbar (abs.) with dry air for at least 15–30 minutes. p.22 ↗ Prevents condensate and impurity deposits on rotors and casing that could prevent restart. C-VLR 401 and C-VLR 501
Oil level must be filled to the middle of the oil sight glass. p.18 ↗ Check oil level through sight glass before commissioning and top up at oil filling point as needed. C-VLR 401 and C-VLR 501
Storage temperature range: -20 °C to +70 °C; relative air humidity max. 80%; storage not more than 6 months. p.13 ↗ Store in dry, dust-free, vibration-free, sun-protected area with openings sealed air-tight. C-VLR 401 and C-VLR 501
Output reduction noticeable when installed at more than 1000 m above sea level. p.18 ↗ Contact manufacturer for high-altitude installations to account for reduced pumping capacity. C-VLR 401 and C-VLR 501
XD model is suitable for conveying water-damp gases (water vapour) and has a condensate drain on the silencer. p.8 ↗ Select XD variant for humid or water-vapour applications; regularly discharge condensate. XD model
Motor protection switch should have overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1). p.19 ↗ Prevents nuisance tripping during cold starts; select motor protection circuit breaker accordingly. C-VLR 401 and C-VLR 501
Integral non-return valve prevents ventilation of evacuated system after pump stops and may not be removed. p.15 ↗ Do not remove non-return valve during installation or maintenance. C-VLR 401 and C-VLR 501

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.30 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.30 ↗ Connection to motor terminal board is not correct Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.30 ↗ Motor protection switch is not set correctly Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.30 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Suction capacity is insufficient p.30 ↗ Air filter is polluted Clean/replace air filter Chapter 7.6, Chapter 7.9
Suction capacity is insufficient p.30 ↗ The inlet pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Suction capacity is insufficient p.30 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 5.3
Final pressure (max. vacuum) is not reached p.30 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 5.3
Final pressure (max. vacuum) is not reached p.30 ↗ Air filter is polluted Clean/replace air filter Chapter 7.6, Chapter 7.9
Machine gets too hot p.30 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Machine gets too hot p.30 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.30 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.4
The machine makes a strange noise p.30 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service