BINDER KB PRO 260
BINDER KB PRO 260 — Incubators with Temperature -20…100 °C.
The KB PRO 260 is a 262 L single-phase cooling incubator with a -20 to 100 °C working range, 0.1 K fluctuation and 0.2 K uniformity, positioned mid-series between the 130 and 470. Its 800 W heat compensation and 200 kg permitted load support high-dissipation or dense loads, while the 40 kg per-rack limit defines shelf loading.
Direct drop-in replacements
BINDER KB PRO Series — Model Comparison & Selection
| Model | Temperature, °C | Depth, cm | Height, cm | Interior volume, L | Interior width, mm | Load per rack, kg |
|---|---|---|---|---|---|---|
| KB PRO 260 Current | -20–100 | 90 | 139.6 | 262 | 656 | 40 |
| KB PRO 1060 | -20–100 | 117.5 | 195.1 | 1070 | 1011 | 40 |
| KB PRO 130 | -20–100 | 71 | 100.5 | 127 | 656 | 30 |
| KB PRO 1600 | -20–100 | 117.5 | 195.1 | 1610 | 1521 | 40 |
| KB PRO 470 | -20–100 | 90 | 195.1 | 472 | 656 | 40 |
| KB PRO 720 | -20–100 | 90 | 195.1 | 727 | 1011 | 40 |
Full specifications
| Temperature | -20...100 °C |
| Interior volume | 262 L |
| Load per rack | 40 kg |
| Max. heat compensation | 800 W |
| Nominal power | 1.5 kW |
| Permitted load | 200 kg |
| Temperature fluctuation | 0.1 K |
| Temperature uniformity | 0.2 K |
| Back wall clearance | 100 mm |
| Side wall clearance | 180 mm |
| Article Number mfr | 9020 |
| Recovery time after door was opened for 30 s at 37°C mfr | 3 min |
| Depth | 900 mm |
| Height | 1396 mm |
| Interior width | 656 mm |
| Width | 930 mm |
| Net weight of the unit (empty) mfr | 190 kg |
| Power frequency | 50 Hz |
| Rated voltage | 208...240 V |
| Unit fuse | 16.0 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The KB PRO 260 (Art. 9020, designation 260) is the third size in the KB PRO cooling incubator line, above the 130 and below the 470, 720, 1060 and 1600. All siblings share the -20...100 °C range; the 260 is distinguished by a 262 L interior (656 mm wide, 900 mm deep, 1,396 mm high) and a 930 mm net width.
- Unlike the 130 and 470, the 260 does not use the flexible tilt protection kit; instead, from size 260 upward a wall spacer is required to maintain the specified rear and side clearances.
- The chamber uses a triangular instrument panel (shared with the 130), whereas the larger 470 and above use a signal triangle with an ergonomically adjustable control terminal.
Behavior under load and in different media
- Temperature control is specified at 0.1 K fluctuation and 0.2 K uniformity across the -20...100 °C range, with a 3-minute recovery after a 30 s door opening at 37 °C.
- The 800 W maximum heat compensation allows the chamber to hold setpoint against substantial internal heat loads; the 200 kg permitted load and 40 kg per-rack limit define how that load may be distributed.
- Refrigeration uses a hydrocarbon refrigerant (R290 in the series type plate data) with a maximum operating pressure of 28 bar; defrosting and anti-condensation protection are handled by dedicated controller functions.
Installation, connection and control
- Electrical supply is single-phase 208...240 V, 50 Hz, with a 1.5 kW nominal power and a 16.0 A unit fuse; the data sheet specifies a CEE 7/7 plug for the standard 230 V version.
- The MB2 chamber controller provides fixed-value, timer, time-program and week-program modes, a chart recorder display, alarm and notification functions, and user management with password-protected authorization levels.
- Temperature safety is provided per DIN 12880:2007 class 2/3.3, selectable as temperature limiter (class 2) or temperature protection (class 3.3), with optional class 3.2 undertemperature protection.
- Communication options include Ethernet, E-Mail and USB data transfer; APT-COM 4 software, analog outputs, zero-voltage alarm contacts, internal LED light, door lock and a flexible Pt 100 object temperature sensor are available as options.
Integration & Operating Notes
The unit is rated 208...240 V, 1~, 50 Hz with 1.5 kW nominal power and a 16.0 A unit fuse. The upstream branch protection and wiring must be sized for this current, and the supply voltage and frequency must be verified before connection; the standard version is fitted with a CEE 7/7 plug.
Rack loading is limited to 40 kg per rack and the total permitted load is 200 kg. Distribute heavy or dense samples accordingly; exceeding the per-rack limit risks deformation of the rack and obstruction of airflow, which would degrade the specified 0.2 K uniformity.
The refrigerant circuit contains a hydrocarbon refrigerant and operates at up to 28 bar. Any work on the refrigeration system must be performed by personnel trained to EN 13313:2010 and documented; door gasket replacement must be done only with the chamber cold to avoid damaging the gasket.
Selection & Integration Q&A
Pick the 260 when 262 L interior and 200 kg load capacity are needed but floor space favors a 930 mm width; the 130 is smaller, while the 470 and above add the adjustable control terminal and larger volume. The 260 uses the triangular panel and requires the wall spacer.
A single-phase 208...240 V, 50 Hz supply with a 16 A branch circuit, matching the 1.5 kW nominal power and 16.0 A unit fuse; the standard version is fitted with a CEE 7/7 plug. Verify voltage and frequency before connection.
Install with the wall spacer, at least 100 mm rear and 180 mm side clearance, and never in an unventilated recess. In dusty air, clean the condenser several times a year to preserve refrigeration performance.
Annual maintenance and the 8760 h/two-year BINDER service reset are not included. Options to order separately: APT-COM 4 software, analog outputs, zero-voltage alarm contacts, internal LED light, door lock, Pt 100 object sensor, and U-rail or telescopic racks.