BINDER KB PRO 720
BINDER KB PRO 720 — Incubators with Temperature -20…100 °C.
The KB PRO 720 is a 727 L forced-convection cooling incubator with a -20 to 100 °C working range and 0.1 K fluctuation, positioned as the mid-large chamber in the KB PRO series. Its 1,000 W heat compensation and 200 kg permitted load distinguish it from smaller siblings, making it suited to high-density batch incubation and temperature cycling in process laboratories.
Direct drop-in replacements
BINDER KB PRO Series — Model Comparison & Selection
| Model | Temperature, °C | Depth, cm | Height, cm | Interior volume, L | Interior width, mm | Load per rack, kg |
|---|---|---|---|---|---|---|
| KB PRO 720 Current | -20–100 | 90 | 195.1 | 727 | 1011 | 40 |
| KB PRO 1060 | -20–100 | 117.5 | 195.1 | 1070 | 1011 | 40 |
| KB PRO 130 | -20–100 | 71 | 100.5 | 127 | 656 | 30 |
| KB PRO 1600 | -20–100 | 117.5 | 195.1 | 1610 | 1521 | 40 |
| KB PRO 260 | -20–100 | 90 | 139.6 | 262 | 656 | 40 |
| KB PRO 470 | -20–100 | 90 | 195.1 | 472 | 656 | 40 |
Full specifications
| Temperature | -20...100 °C |
| Interior volume | 727 L |
| Load per rack | 40 kg |
| Max. heat compensation | 1000 W |
| Nominal power | 1.7 kW |
| Permitted load | 200 kg |
| Temperature fluctuation | 0.1 K |
| Temperature uniformity | 0.2 K |
| Back wall clearance | 100 mm |
| Side wall clearance | 180 mm |
| Article Number mfr | 9020 |
| Recovery time after door was opened for 30 s at 37°C mfr | 4 min |
| Depth | 900 mm |
| Height | 1951 mm |
| Interior width | 1011 mm |
| Width | 1285 mm |
| Net weight of the unit (empty) mfr | 296 kg |
| Power frequency | 50 Hz |
| Rated voltage | 208...240 V |
| Unit fuse | 16.0 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The KB PRO 720 uses a signal triangle instrument panel with an ergonomically adjustable control terminal, unlike the triangular panel of the KB PRO 130/260. It shares the -20…100 °C range with all siblings but offers 727 L interior volume (1,011 mm interior width, 900 mm depth) and a 200 kg permitted load — larger than the 130/260/470 and smaller than the 1060/1600.
- Net weight is 296 kg empty; overall width 1,285 mm, height 1,951 mm. The chamber requires a wall spacer (mandatory from size 260 upward) and specified clearances of 100 mm at the rear and 180 mm at the sides.
Behavior under load and in different modes
- Temperature fluctuation is 0.1 K and uniformity 0.2 K across the working range. Recovery time after a 30 s door opening at 37 °C is 4 min. Maximum heat compensation is 1,000 W, allowing the chamber to hold setpoint against substantial sample heat loads; racks are rated 40 kg each.
- The MB2 controller supports fixed-value, timer, time-program and week-program modes, with ramp/step sections, tolerance ranges and repeats. Defrosting and anti-condensation protection are provided for refrigerating operation.
Installation, connection and control
- Electrical supply is 208…240 V, 1~, 50/60 Hz, nominal power 1.7 kW, nominal current 7.1 A, unit fuse 16.0 A, CEE 7/7 plug. Refrigerant is R290 (0.095 kg fill, max operating pressure 28 bar), requiring hydrocarbon-trained service personnel.
- The controller offers Ethernet and E-Mail communication, USB data transfer, and optional analog outputs, zero-voltage alarm contacts, internal LED light, door lock and flexible Pt 100 object temperature sensor. Temperature safety device is class 2/3.3 per DIN 12880:2007, with class 3.2 undertemperature protection available.
Integration & Operating Notes
From size 260 upward the wall spacer must be fitted, and the chamber needs 100 mm rear and 180 mm side clearance. Installing in an unventilated recess or ignoring these distances prevents heat dispersal and can cause overheating damage.
The unit draws 1.7 kW at 7.1 A nominal on a single phase with a 16.0 A unit fuse. Verify supply voltage and frequency (50/60 Hz) before connection; an undersized or shared branch risks nuisance tripping and invalid temperature runs.
The R290 refrigerant circuit (0.095 kg, max 28 bar) may only be serviced by technicians certified per EN 13313:2010 / Regulation (EC) 303/2008. Plan service contracts accordingly; unauthorized intervention voids safety compliance and may be illegal.
Maintenance is required at least once a year, and a service message appears after 8760 operating hours or two years, repeating every two weeks until reset by BINDER Service. In dusty environments, clean the condenser several times a year by suction.
Replacing the door gasket while the chamber is warm will damage the gasket. Schedule gasket replacement with the chamber at ambient temperature, and include electrical safety testing per EN 50678/VDE 0701 and EN 50699/VDE 0702 at commissioning and after repair.
Selection & Integration Q&A
Pick the 720 when 727 L and a 200 kg load are needed but the 1060/1600 footprint is too large; the 470 suits smaller batches. All share -20…100 °C, but only the 720 balances 1,000 W heat compensation with a mid-size 1,285 mm width.
It needs 208–240 V single-phase, 50/60 Hz, 7.1 A nominal (1.7 kW) with a 16.0 A unit fuse and CEE 7/7 plug. Size the branch for the full 7.1 A; sharing with other high-draw equipment risks voltage dips that disturb the 0.1 K control stability.
Fit the wall spacer (mandatory from size 260) and keep 100 mm rear and 180 mm side clearance. Do not install in unventilated recesses; ensure heat dispersal. In dusty air, clean the condenser several times a year to protect refrigeration performance.
Base delivery excludes APT-COM 4 software, analog outputs, zero-voltage alarm contacts, internal LED light, door lock and the flexible Pt 100 sensor. Annual maintenance and electrical safety tests are required; a service message appears at 8760 h or two years until reset by BINDER Service.