BINDER MK 720
BINDER ·Made in Germany · In Active Production

BINDER MK 720

BINDER MK 720 — Climate chambers with Temperature -40…180 °C.

The BINDER MK 720 is a 734-litre dynamic climate chamber built for rapid temperature cycling between -40 °C and 180 °C, with a 4.0 K/min average heating rate and a 100-minute full-span cool-down. Its 8.7 kW electrical demand and 570 kg empty mass place it in the large-frame class of the MK series, intended for batch testing of bulky assemblies under reproducible thermal profiles.

Temperature
-40…180 °C

BINDER MK Series — Model Comparison & Selection

Model Temperature, °CDepth, cmHeight, cmInterior height, mmInterior volume, LInterior width, mm
MK 720 Current -40–180114200.510207341200
MK 1020 -40–180148200.510209911200
MK 1020 CO₂ -48–180148200.510209911200
MK 115 -40–18086.5172.5480115600
MK 240 -40–18092.5171700228735
MK 240 CO₂ -50...18092.5171700228735
MK 400 -40–180140171700417735
MK 400 CO₂ -50...180140171700417735
MK 56 -40–18077.8144.542060400
MK 720 CO₂ -48–180114200.510207341200

Full specifications

Core Performance & Functional Specifications
Temperature -40...180 °C
Interior volume 734 L
Load per rack 40 kg (MK720-400V, 50 Hz)
Nominal power 8.7 kW
Article Number mfr 9020
Dimensions, Weight & Mechanical Design
Depth 1140 mm (MK720-400V, 50 Hz)
Height 2005 mm (MK720-400V, 50 Hz)
Interior height 1020 mm (MK720-400V, 50 Hz)
Interior width 1200 mm (MK720-400V, 50 Hz)
Width 1580 mm (MK720-400V, 50 Hz)
Net weight of the unit (empty) mfr 570 kg
Electrical, Power & Drive Specifications
Power frequency 50 Hz
Rated voltage 400 V
Unit fuse 16.0 A
Phase (Nominal voltage) mfr 3 N/PE
Operating Conditions, Environment & Protection
Cooling down time from 180°C to -40°C mfr 100 min
Standards, Safety & General Data
Average heating-up rate according to IEC 60068-3-5 between -40°C and 180°C mfr 4.0 K/min

Description

Construction and series positioning

Thermal behaviour

Electrical and control architecture

Integration & Operating Notes

Electrical
400 V 3 N/PE supply with 16 A fuse must be dedicated

The 8.7 kW nominal load on a 400 V three-phase neutral-earthed supply requires a dedicated 16.0 A fused circuit; sharing the circuit with other high-draw equipment risks nuisance tripping during heat-up and invalidates the specified ramp rates. Confirm the site neutral is bonded and the supply frequency is 50 Hz before ordering the standard variant.

Data Sheet Model MK 720 en.pdf, electrical specifications
Process Limits
Rack loading capped at 40 kg per shelf level

Each rack position is rated for 40 kg; distributing heavy specimens across multiple levels rather than concentrating them on one shelf preserves airflow and avoids exceeding the structural limit. Uneven loading also degrades the 0.3…2.0 K uniformity figure, which is specified for defined conditions.

Data Sheet Model MK 720 en.pdf, load per rack
Electrical
480 V 60 Hz sites need the separate MK720-480V-C order code

The standard 9020-0377 unit is 400 V 50 Hz only. For 480 V 3~ 60 Hz installations the MK720-480V-C (9020-0356) with integrated voltage and frequency converter is the correct article; specifying the standard unit for a 60 Hz grid is a configuration error that cannot be corrected in the field.

Data Sheet Model MK 720 en.pdf, scope and variants

Selection & Integration Q&A

When should I choose the MK 720 rather than the MK 240 or MK 1020?

Pick the 720 when specimen batches need more than the MK 240's working volume but do not justify the MK 1020's larger frame; its 734 L interior and 40 kg per-rack rating suit multi-shelf loads of bulky assemblies. The 1020 is the step up only if the 720's 1,200 mm interior width is insufficient.

What supply and protection does the MK 720 require at the installation point?

The standard MK720-400V needs 400 V 3 N/PE 50 Hz with a 16.0 A unit fuse and draws 8.7 kW nominal; provide a dedicated fused circuit. Sites on 480 V 3~ 60 Hz must order the MK720-480V-C variant with its converter instead of the standard article.

What is not included in the base delivery that I must plan for?

The data sheet digest lists only the chamber and, for the 480 V variant, the integrated converter; racks, specimen fixtures, interface cables and any calibration accessories are not stated as included. Confirm the delivery scope and required rack quantities against the order documentation before commissioning.

Dimensional Drawings & Technical Documentation

Dimensional drawings

MK 720 — drawing 1

Click drawing to inspect vector dimensions

Technical documentation

PDF
Data Sheet Model MK 720 en
Datasheet ·825,6 КБ ·8 pp.
View PDF