BINDER MK 1020
BINDER MK 1020 — Climate chambers with Temperature -40…180 °C.
The BINDER MK 1020 is a 991 L dynamic climate chamber for rapid temperature cycling from -40 °C to 180 °C, with average heating/cooling rates of 5.5/5.0 K/min per IEC 60068-3-5. As the largest MK series model, it is distinguished by its 1200 mm interior width and 40 kg per rack load capacity, and is the only MK size besides the MK 56 to offer water cooling. It is intended for reproducible temperature stress testing of large components and batches in a laboratory or production environment.
BINDER MK Series — Model Comparison & Selection
| Model | Temperature, °C | Depth, cm | Height, cm | Interior height, mm | Interior volume, L | Interior width, mm |
|---|---|---|---|---|---|---|
| MK 1020 Current | -40–180 | 148 | 200.5 | 1020 | 991 | 1200 |
| MK 1020 CO₂ | -48–180 | 148 | 200.5 | 1020 | 991 | 1200 |
| MK 115 | -40–180 | 86.5 | 172.5 | 480 | 115 | 600 |
| MK 240 | -40–180 | 92.5 | 171 | 700 | 228 | 735 |
| MK 240 CO₂ | -50...180 | 92.5 | 171 | 700 | 228 | 735 |
| MK 400 | -40–180 | 140 | 171 | 700 | 417 | 735 |
| MK 400 CO₂ | -50...180 | 140 | 171 | 700 | 417 | 735 |
| MK 56 | -40–180 | 77.8 | 144.5 | 420 | 60 | 400 |
| MK 720 | -40–180 | 114 | 200.5 | 1020 | 734 | 1200 |
| MK 720 CO₂ | -48–180 | 114 | 200.5 | 1020 | 734 | 1200 |
Full specifications
| Temperature | -40...180 °C |
| Interior volume | 991 L |
| Load per rack | 40 kg (MK1020-400V) |
| Nominal power | 11.5 kW |
| Article Number mfr | 9020 |
| Depth | 1480 mm (MK1020-400V) |
| Height | 2005 mm (MK1020-400V) |
| Interior height | 1020 mm (MK1020-400V) |
| Interior width | 1200 mm (MK1020-400V) |
| Width | 1580 mm (MK1020-400V) |
| Net weight of the unit (empty) mfr | 621 kg |
| Power frequency | 50 Hz |
| Rated voltage | 400 V |
| Unit fuse | 32.0 A |
| Phase (Nominal voltage) mfr | 3 N/PE |
| Cooling down time from 180°C to -40°C mfr | 120 min |
| Average heating-up rate according to IEC 60068-3-5 between -40°C and 180°C mfr | 5.5 K/min |
Description
Construction and series positioning
- The MK 1020 is the largest chamber in the MK (E5) series, with 991 L usable volume and interior dimensions of 1200 mm (W) × 1020 mm (H) × 1480 mm (D).
- Unlike smaller MK 115 and MK 240 models, the MK 1020 is available only in 400 V three-phase configuration (MK1020-400V) or with an integrated voltage and frequency changer (MK1020-400V-C).
- The CO₂ variants (MK 1020 CO₂) extend the low-temperature limit to -48 °C; the standard MK 1020 covers -40 °C to 180 °C.
- Water cooling is a factory option exclusive to the MK 56 and MK 1020, making the MK 1020 suitable for high-ambient or continuous-duty installations where air cooling is insufficient.
Thermal behavior and load
- The chamber achieves an average heating rate of 5.5 K/min and cooling rate of 5.0 K/min between -40 °C and 180 °C according to IEC 60068-3-5; a full cool-down from 180 °C to -40 °C takes 120 minutes.
- Temperature uniformity is 0.1...1.8 K and fluctuation 0.1...0.5 K, both dependent on set value, ensuring stable conditions for test specimens up to 40 kg per rack.
- The 11.5 kW nominal power and 32 A unit fuse reflect the high thermal capacity required for rapid cycling of the large interior volume.
Installation, control and operation
- The chamber is equipped with the MB2 program controller featuring a touchscreen, Ethernet interface, and support for time and week programs with ramp/step functions.
- Electrical connection requires a 3 N/PE 400 V 50 Hz supply; the -C variant adds a voltage and frequency changer for 480 V 60 Hz networks, with separate installation instructions.
- The chamber must be installed with sufficient ventilation and minimum clearances; it must not be placed in unventilated recesses or damp areas.
- Safety devices include an over-temperature protective device class 1 and a temperature safety device per DIN 12880 class 2.0; an optional over/under temperature safety device class 2 is available.
Integration & Operating Notes
The MK 1020 draws 11.5 kW at 400 V 3 N/PE 50 Hz and must be protected by a 32 A fuse. Verify that the site provides a three-phase supply with adequate short-circuit capacity and that the neutral and protective earth are correctly bonded; an undersized supply will cause tripping during heating or cooling ramps.
The chamber requires sufficient ventilation for heat dispersal and must observe minimum distances to walls and ceilings. Installation in unventilated recesses can cause overheating and damage. Damp areas or puddles are prohibited due to electric shock hazard; the chamber must remain dry during operation, cleaning and maintenance.
The chamber has no explosion protection measures and must not be operated in potentially explosive areas or with combustible dust or air-solvent mixtures present. Site classification and the selection of charging materials must exclude flammable substances at working temperature to prevent ignition.
The over-temperature protective device class 1 responds if the nominal temperature is exceeded by 20 °C due to chamber failure. A class 1 trip requires the chamber to be taken out of operation immediately and BINDER Service to be informed; it is not a normal process alarm and must not be reset without investigating the cause.
An annual repeat electrical inspection is required, as well as a test prior to initial startup and prior to resuming operation after maintenance or repair. Testing under EN 50678/VDE 0701 and EN 50699/VDE 0702 is recommended. Schedule these inspections to maintain compliance and ensure electrical safety.
The water cooling option, with separate cooling water inlet and outlet connections, is available only for the MK 56 and MK 1020 models. If water cooling is required, it must be specified at ordering and the plumbing connections planned accordingly; other MK sizes cannot be retrofitted with this option.
Selection & Integration Q&A
Choose the MK 1020 when you need a large interior volume (991 L) and higher load capacity (40 kg per rack) for testing large components or batches. The MK 240 and MK 115 offer smaller volumes and are limited to 400 V or 230 V respectively; the MK 1020 is the only MK size besides the MK 56 to offer water cooling, making it suitable for high-ambient or continuous-duty installations.
The chamber must not be installed in unventilated recesses; sufficient ventilation for heat dispersal and minimum distances per chapter 3.4 must be observed. It must not be placed in damp areas or puddles, and must not be operated in hazardous locations or potentially explosive atmospheres. Ambient conditions should be free of combustible dust and air-solvent mixtures.
A maintenance message appears after 8760 operating hours or two years, recurring every two weeks until reset by BINDER Service. An annual electrical safety inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 is required. Base delivery excludes options such as RS485 interface, analog temperature outputs, flexible Pt 100 sensor, compressed air connection/dryer, water cooling, APT-COM™ 4 software, and over/under temperature safety device class 2; these must be ordered separately.