Peter Huber Kältemaschinenbau Minichiller 1000w Kompakter
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Minichiller 1000w Kompakter

Peter Huber Kältemaschinenbau Minichiller 1000w Kompakter — Recirculating chillers.

The Minichiller 1000w Kompakter is a water-cooled recirculating chiller with a pressure/suction pump and Pilot ONE controller, covering -20 to 40 °C. It is the 'w' (water-cooled) variant of the 1000 series, requiring 3–6 bar cooling-water pressure. It serves as a compact cooling source for laboratory and pilot processes needing up to 24 l/min flow.

Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Minichiller 1000w Kompakter Current —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Minichiller 1000 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1000w-H Kompakter —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Minichiller 1000w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1200-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1200 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1200w-H Kompakter —Pilot ONEIII / FL-20–100——
Minichiller 1200w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 280 OLÉ Kompakter 53OLÉI / NFL-5–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300 OLÉ Kompakter 53OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300w-H OLÉ Kompakter 51OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300w OLÉ Kompakter 53OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 600-H OLÉ Kompakter 56OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 600 Kompakter —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D110-120V 1~ 60Hz
Minichiller 600 OLÉ Kompakter 56OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 60Hz
Minichiller 600w OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 800 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 800w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz

Full specifications

Core Performance & Functional Specifications
Maximum delivery flow rate 24 l/min (max.; pressure 0, 7 bar)
Pump connection M16x1 AG male
Pump speed adjustable Yes
Pump type Pressure- and suction pump
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 208-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water differential pressure 3 bar (min.)
Cooling Water Pressure 6 bar (max.)
Maximum return flow temperature 80 °C (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The Minichiller 1000w Kompakter is a water-cooled recirculating chiller in the Minichiller series. Unlike air-cooled siblings (e.g., Minichiller 1000-H, 1000 OLÉ), this 'w' modification uses a water-cooled refrigeration circuit, making it dependent on an external cooling-water supply. The pump is a pressure- and suction type with adjustable speed, connected via M16x1 male threads. Cooling-water connections are G1/2 male. The unit is controlled by the Pilot ONE controller and offers Ethernet, USB (host and device), and RS232 interfaces. Protection rating is IP20, safety class I/NFL.

Operating behavior and media

Installation and operation

Install indoors, protected from water ingress (IP20), with a drip tray below the unit. Do not install in ATEX zones. Electrical lines below the unit must be protected against liquid ingress. Do not install valves or quick-release couplings in feed/discharge lines. The unit must not be moved while operating. Cooling water must be drinking water or filtered river/sea water; sea water is prohibited. Anti-corrosion agents are mandatory if salts are added.

Integration & Operating Notes

Cooling & Media
Cooling water differential pressure must be at least 3 bar

The water-cooled refrigeration circuit requires a minimum differential pressure of 3 bar to function; lower pressure will prevent proper cooling and may cause the compressor to trip. Verify the building chilled-water supply can sustain this differential at the required flow.

Minichiller 1000w Technical Data, page 1
Cooling & Media
Supply pressure above 6 bar damages the refrigeration circuit

The cooling-water supply pressure must not exceed 6 bar. If the building water line is higher, install a pressure reducer upstream of the G1/2 male connection to avoid overpressure damage to the water-cooled condenser.

Minichiller 1000w Technical Data, page 1
Process Limits
Return-line temperature must not exceed 80 °C

Connected piping, hoses, and components in the return line must be rated for at least 80 °C. Exceeding this limit can damage the chiller and pose a burn hazard. Ensure the application's heat load does not raise the return fluid above this value.

Minichiller 1000w Technical Data, page 2
Process Limits
Plastic pump incompatible with acetone and polyglycols

The pump's plastic materials are not resistant to acetone or polyglycols (depending on manufacturer). Using these fluids will degrade the pump and void reliable operation. Select an alternative fluid or a different pump material for such media.

Minichiller 1000w Technical Data, page 2
Mounting
Install a drip tray below the unit

The responsible body must install a condensation water / thermal fluid drip tray below the temperature control unit to contain leaks and condensation. This is required to protect the installation area and prevent slip hazards.

Minichiller Operation Manual, page 15
Mounting
Do not install in an ATEX zone

Operation within an ATEX zone can cause explosion due to the flammable R-290 refrigerant. The unit must be installed in a non-hazardous area with adequate ventilation per the refrigerant charge and room size.

Minichiller Operation Manual, page 13
Electrical
Voltage tolerance ±5% with frequency tolerance ±2%

The power supply must be within ±5% voltage and ±2% frequency simultaneously; certain combinations are not allowed. Check site power quality before installation to avoid erratic operation or damage to the controller and compressor.

Minichiller 1000w Technical Data, page 2
Maintenance
Anti-corrosion agents mandatory if salts are added

If chlorides, bromide, or other salts are added to the water circuit, anti-corrosion agents are mandatory to protect the copper, stainless steel 1.4401, MS, PA, PPE, PTFE, and EPDM materials from corrosion damage.

Minichiller Operation Manual, page 28

Selection & Integration Q&A

When should I choose the Minichiller 1000w Kompakter instead of an air-cooled sibling like the 1000-H?

Choose the 'w' water-cooled version when a reliable chilled-water supply (3–6 bar differential) is available and air-cooled units would reject too much heat to the room. Air-cooled siblings are preferable where no cooling-water infrastructure exists.

What are the requirements for the cooling-water supply and the process circuit connections?

Cooling water: G1/2 male, differential pressure min. 3 bar, supply pressure max. 6 bar, intake 5–20 °C. Process circuit: M16x1 male pump connections; do not install valves or quick-release couplings in feed/discharge lines. Return line must withstand 80 °C.

What are the ambient and installation limits for the Minichiller 1000w Kompakter?

Ambient 5–40 °C, indoor dry location (IP20), not in ATEX zone. Install a drip tray below. Protect electrical lines below the unit from liquid ingress. Ensure room volume and refrigerant charge (R-290) comply with safety limits.

What maintenance and accessories are required that are not included in the base delivery?

A drip tray must be installed by the responsible body. Anti-corrosion agents are required if salts are added. For freeze protection below 0 °C, mix water with glysantine or ethylene glycol. No cables or hoses are included; order M16x1 and G1/2 fittings separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Minichiller Operation Manual
Manual ·2,9 МБ ·84 pp.
View PDF
PDF
Minichiller 1000w Technical Data
Datasheet ·30,9 КБ ·2 pp.
View PDF