Peter Huber Kältemaschinenbau Minichiller 1200-H OLÉ Kompakter
Peter Huber Kältemaschinenbau Minichiller 1200-H OLÉ Kompakter — Recirculating chillers.
The Minichiller 1200-H OLÉ Kompakter is a compact recirculating chiller with a pressure/suction pump and OLÉ controller, covering -20 to 100 °C. It is the 1.2 kW-class air-cooled modification in the Minichiller series, distinguished by its R-1270 (A3) refrigerant and fixed-speed pump. It serves as a point-of-use cooling source for laboratory and pilot processes requiring stable temperature control.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 1200-H OLÉ Kompakter Current | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600-H OLÉ Kompakter | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600 OLÉ Kompakter | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Maximum delivery flow rate | 24 l/min (pressure pump; 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure- and suction pump |
| Temperature range | -20...100 °C |
| Weight | 38 kg |
| Current consumption | 12 A |
| Fuse rating | 16 A |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Air-cooled recirculating chiller with integrated pressure/suction pump, OLED display and OLÉ controller; safety class III/FL per DIN 12876.
- Within the Minichiller series, this 1200-H OLÉ variant sits above the 1000-series siblings (1000-H, 1000-H OLÉ, 1000 OLÉ, 1000w-H) in cooling capacity class; the 'H' suffix and OLÉ controller define this configuration.
- Refrigerant is R-1270 (A3, H220, GWP 0), a flammable natural refrigerant that imposes site ventilation and ignition-source precautions.
- Pump connections are M16x1 male; the pump is a fixed-speed pressure/suction type (not speed-adjustable).
Thermal behavior and capacity
- Working range -20 to 100 °C. Cooling capacity is strongly temperature-dependent: 1.2 kW at 15 °C falling to 0.35 kW at -20 °C, so sizing must use the actual set point, not the nominal figure.
- Published capacity is valid at 20 °C room temperature; higher ambient reduces available cooling.
- Whisper mode lowers sound to 51 dB(A) but also reduces delivery to 14 l/min at 0.2 bar, so process heat load must be checked before enabling it.
Installation, control and operation
- Supply is 208-240 V 1~/2~ 50/60 Hz with 16 A fuse and max 12 A current; voltage/frequency tolerances ±5%/±2%, but -5% voltage with +2% frequency is not permitted.
- Interfaces: USB (Device) and RS232. Display resolution 0.1 K.
- IP20 protection and 5-40 °C ambient limit restrict placement to dry, temperate locations; a drip tray is required below the unit and electrical lines below must be protected against liquid ingress.
- The plastic pump is not resistant to acetone or polyglycols; freeze protection requires glysantine or ethylene glycol mixtures.
Integration & Operating Notes
Condensation and thermal fluid can escape at the pump connections and drain area. The responsible body must install a condensation water/thermal fluid drip tray below the unit, and any electrical lines routed directly underneath must be protected against liquid ingress to avoid shock hazard.
The cooling water circuit accepts drinking water or filtered river/sea water, but sea water must not be used. If salts such as chlorides or bromide are added, anti-corrosion agents are mandatory to prevent corrosion damage to the circuit.
The unit accepts ±5% voltage and ±2% frequency, but the combination of -5% voltage with +2% frequency is explicitly not allowed. Check site supply quality against this rule; also provision a 16 A fuse and specify the country-specific plug at ordering.
The plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). Select an alternative fluid or a more resistant pump option if the process requires these media, otherwise pump life and leak integrity are at risk.
A drain valve (#6839) is an optional accessory, not part of base delivery. Without it, gravity drainage for fluid replacement and maintenance is not possible, so plan the accessory into the initial order if routine fluid changes are expected.
Operation in an ATEX zone can cause explosion and is prohibited. IP20 protection and the 5-40 °C ambient limit mean the unit cannot be placed in wet or hot environments; also check refrigerant charge against room volume to stay below the limit value per m³.
Selection & Integration Q&A
Pick the 1200-H OLÉ when your heat load needs the higher capacity class and you want the OLÉ controller; the 1000-series siblings (1000-H, 1000-H OLÉ, 1000 OLÉ, 1000w-H) cover lower loads. Size against actual set point: capacity falls from 1.2 kW at 15 °C to 0.35 kW at -20 °C.
Loop fittings must match M16x1 male pump connections, with no valves or quick-release couplings in the feed/discharge lines. Supply must be 208-240 V 1~/2~ 50/60 Hz, 16 A fuse, max 12 A, with country-specific plug specified at ordering; USB and RS232 are available for control.
Install only in 5-40 °C ambient, non-ATEX, dry locations (IP20); a drip tray is required below the unit and cables underneath must be protected from liquid. Do not move the unit while operating. Whisper mode cuts flow to 14 l/min at 0.2 bar, so verify heat load before enabling it.
The drain valve (#6839) is optional and must be ordered separately for gravity fluid changes. Freeze protection requires glysantine or ethylene glycol mixed with water; anti-corrosion agents are mandatory if chlorides or bromide are added. The power cable and country-specific plug must be specified at ordering.