Technical Data Sheet — C-VLR 1000 HV vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Bomba de vacío de garras secas C-VLR 1000 HV+ con accionamiento de velocidad variable (VSD); tamaño único 1000 HV+; alimentación del convertidor de frecuencia 3~ 400 (-15 %) – 480 V (+10 %), 47–63 Hz; motor nominal 400 V, frecuencia de corte 60 Hz.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Nominal suction capacity | 380 – 1140 m³/h p.1 ↗ | C-VLR 1000 HV+ |
| Ultimate vacuum at continuous operation | 200 mbar (abs.) p.1 ↗ | C-VLR 1000 HV+ |
| Connection voltage frequency converter | 400 (-15 %) – 480 V (+10 %) (47 – 63 Hz) V p.1 ↗ | 3~, C-VLR 1000 HV+ |
| Current drawn frequency converter | 39,9 A p.1 ↗ | C-VLR 1000 HV+ |
| Motor rating | 22,0 kW p.1 ↗ | C-VLR 1000 HV+ |
| Rated voltage motor | 400 V p.1 ↗ | 3~, C-VLR 1000 HV+ |
| Cut-off frequency motor | 60 Hz p.1 ↗ | C-VLR 1000 HV+ |
| Main fuse | 63 A p.1 ↗ | C-VLR 1000 HV+ |
| Speed | 1200 – 3600 (20 – 60 Hz) min-1 p.1 ↗ | C-VLR 1000 HV+ |
| Average noise level | 78 – 82 (50 – 60 Hz) dB(A) p.1 ↗ | EN ISO 3744, C-VLR 1000 HV+ |
| max. weight without motor | 790 kg p.1 ↗ | C-VLR 1000 HV+ |
| Oil capacity | 2,8 l p.1 ↗ | C-VLR 1000 HV+ |
| Protection class | IP 55 p.1 ↗ | C-VLR 1000 HV+ |
| Motor protection | PTC Sensor p.1 ↗ | C-VLR 1000 HV+ |
Operating Limits
- Ultimate vacuum at continuous operation: 200 mbar (abs.) p.1 ↗
- Frequency converter supply frequency: 47 – 63 Hz p.1 ↗
- Speed range: 1200 – 3600 min-1 (20 – 60 Hz) p.1 ↗
- Protection class: IP 55 p.1 ↗