BINDER MK 720
BINDER MK 720 — Climate chambers with Temperature -40…180 °C.
The BINDER MK 720 is a 734-litre dynamic climate chamber built for rapid temperature cycling between -40 °C and 180 °C, with a 4.0 K/min average heating rate and a 100-minute full-span cool-down. Its 8.7 kW electrical demand and 570 kg empty mass place it in the large-frame class of the MK series, intended for batch testing of bulky assemblies under reproducible thermal profiles.
BINDER MK Series — Model Comparison & Selection
| Model | Temperature, °C | Depth, cm | Height, cm | Interior height, mm | Interior volume, L | Interior width, mm |
|---|---|---|---|---|---|---|
| MK 720 Current | -40–180 | 114 | 200.5 | 1020 | 734 | 1200 |
| MK 1020 | -40–180 | 148 | 200.5 | 1020 | 991 | 1200 |
| MK 1020 CO₂ | -48–180 | 148 | 200.5 | 1020 | 991 | 1200 |
| MK 115 | -40–180 | 86.5 | 172.5 | 480 | 115 | 600 |
| MK 240 | -40–180 | 92.5 | 171 | 700 | 228 | 735 |
| MK 240 CO₂ | -50...180 | 92.5 | 171 | 700 | 228 | 735 |
| MK 400 | -40–180 | 140 | 171 | 700 | 417 | 735 |
| MK 400 CO₂ | -50...180 | 140 | 171 | 700 | 417 | 735 |
| MK 56 | -40–180 | 77.8 | 144.5 | 420 | 60 | 400 |
| MK 720 CO₂ | -48–180 | 114 | 200.5 | 1020 | 734 | 1200 |
Full specifications
| Temperature | -40...180 °C |
| Interior volume | 734 L |
| Load per rack | 40 kg (MK720-400V, 50 Hz) |
| Nominal power | 8.7 kW |
| Article Number mfr | 9020 |
| Depth | 1140 mm (MK720-400V, 50 Hz) |
| Height | 2005 mm (MK720-400V, 50 Hz) |
| Interior height | 1020 mm (MK720-400V, 50 Hz) |
| Interior width | 1200 mm (MK720-400V, 50 Hz) |
| Width | 1580 mm (MK720-400V, 50 Hz) |
| Net weight of the unit (empty) mfr | 570 kg |
| Power frequency | 50 Hz |
| Rated voltage | 400 V |
| Unit fuse | 16.0 A |
| Phase (Nominal voltage) mfr | 3 N/PE |
| Cooling down time from 180°C to -40°C mfr | 100 min |
| Average heating-up rate according to IEC 60068-3-5 between -40°C and 180°C mfr | 4.0 K/min |
Description
Construction and series positioning
- The MK 720 occupies the upper end of the MK series: its 734 L interior (1,200 mm wide × 1,020 mm high) is roughly three times the MK 240 and six times the MK 115, while the MK 1020 remains larger. The 720 is the practical choice when specimen racks or fixtures exceed the 40 kg per-rack load limit of smaller frames but the 1020's footprint is not justified.
- The chamber is a floor-standing cabinet with 1,580 mm external width, 1,140 mm depth and 2,005 mm height; the 570 kg empty weight and 8.7 kW nominal power mean it is not a benchtop or mobile unit.
Thermal behaviour
- The working range spans -40 °C to 180 °C. Temperature uniformity is stated as 0.3…2.0 K and fluctuation as 0.1…0.5 K, both dependent on set value, so tight uniformity is achieved near the middle of the range rather than at the extremes.
- The 4.0 K/min average heating rate (IEC 60068-3-5, -40 °C to 180 °C) and the 100-minute cool-down from 180 °C to -40 °C define the fastest full-span transitions; partial-span cycles are correspondingly shorter. No digitized curve points were supplied, so rate-versus-temperature behaviour between the endpoints is not characterised here.
Electrical and control architecture
- The standard MK720-400V variant (Art.-No. 9020-0377) operates on 400 V 3 N/PE 50 Hz with a 16.0 A unit fuse. A second variant, MK720-480V-C (Art.-No. 9020-0356), adds a voltage and frequency converter for 480 V 3~ 60 Hz sites; the two are distinct order codes and must not be mixed.
- The data sheet digest does not detail controller I/O, interface protocols or programming modes; those must be taken from the full operating manual before integration with a test sequencer.
Integration & Operating Notes
The 8.7 kW nominal load on a 400 V three-phase neutral-earthed supply requires a dedicated 16.0 A fused circuit; sharing the circuit with other high-draw equipment risks nuisance tripping during heat-up and invalidates the specified ramp rates. Confirm the site neutral is bonded and the supply frequency is 50 Hz before ordering the standard variant.
Each rack position is rated for 40 kg; distributing heavy specimens across multiple levels rather than concentrating them on one shelf preserves airflow and avoids exceeding the structural limit. Uneven loading also degrades the 0.3…2.0 K uniformity figure, which is specified for defined conditions.
The standard 9020-0377 unit is 400 V 50 Hz only. For 480 V 3~ 60 Hz installations the MK720-480V-C (9020-0356) with integrated voltage and frequency converter is the correct article; specifying the standard unit for a 60 Hz grid is a configuration error that cannot be corrected in the field.
Selection & Integration Q&A
Pick the 720 when specimen batches need more than the MK 240's working volume but do not justify the MK 1020's larger frame; its 734 L interior and 40 kg per-rack rating suit multi-shelf loads of bulky assemblies. The 1020 is the step up only if the 720's 1,200 mm interior width is insufficient.
The standard MK720-400V needs 400 V 3 N/PE 50 Hz with a 16.0 A unit fuse and draws 8.7 kW nominal; provide a dedicated fused circuit. Sites on 480 V 3~ 60 Hz must order the MK720-480V-C variant with its converter instead of the standard article.
The data sheet digest lists only the chamber and, for the 480 V variant, the integrated converter; racks, specimen fixtures, interface cables and any calibration accessories are not stated as included. Confirm the delivery scope and required rack quantities against the order documentation before commissioning.