Operating Instructions — L-BV2 ATEX (EN)
Technical Reference Summary
Covered Models & Document Scope
This document is an ATEX supplement (610.44440.40.200, edition 11.2019) to the base operating instructions 610.44440.40.000. It covers L-Series liquid ring vacuum pumps/compressors of series L-BV2 | L-BV5 ATEX, types 2BV2060, 2BV2061, 2BV2070, 2BV2071, 2BV5110, 2BV5111, 2BV5121, 2BV5131, 2BV5161. The EC/EU declaration lists variants 2BV2060-..D..-Z, 2BV2061-..D..-Z, 2BV2070-..D..-Z, 2BV2071-..D..-Z, 2BV5110-..D..-Z, 2BV5111-..D..-Z, 2BV5121-..D..-Z, 2BV5131-..D..-Z, 2BV5161-..D..-Z and 2BV2060-..G..-Z, 2BV2070-..G..-Z, 2BV2071-..G..-Z, 2BV5110-..G..-Z, 2BV5121-..G..-Z, with option F91, marked II 2G Ex h IIC T3 Gb. Two constructions exist: normal requirements and higher corrosion-resistance/hygiene requirements (only 2BV2070, 2BV2071 and 2BV5..).
Section-by-Section Technical Breakdown
Replaces point 2 'Intended Use' of the base manual. Defines the ATEX scope: internal space category 2G, temperature class T4 (internal) and T3 (surrounding area) if maximum temperatures are respected, and installation permitted in areas where explosive gas/vapour atmospheres occur occasionally. Lists operating liquid requirements and forbidden applications.
- Suitable for conveying gases/vapours where a potentially explosive atmosphere is occasionally expected; internal space category 2G.
- Temperature class T4 for internal space and T3 for surrounding area if maximum temperatures are complied with.
- Installation for category 2G allowed where explosive gases/vapours occur occasionally.
- Operating liquid ignition temperature must be above 150 °C.
- Normally water with pH 6 to 9; free of foreign matter, crystalline precipitates and sticking/jamming substances.
- Operating liquid heat capacity < 3 kJ/kg K or boiling point not 20 K above input temperature requires manufacturer consultation.
- Forbidden: use in zones 0, 20, 21 and 22; operation with a frequency converter; modifications; dismantling maintenance by operator.
Specifies operating liquid temperature limits and minimum suction pressure conditions. The operating liquid temperature must be between +5 °C and +65 °C with a nominal value of +15 °C. Suction pressure must stand at least 50 mbar above the vapour pressure of the operating fluid, otherwise the manufacturer must be consulted.
- Operating liquid temperature: min +5 °C (+41 °F), nominal +15 °C (+59 °F), max +65 °C (+149 °F).
- Suction pressure p1 min must be at least 50 mbar above vapour pressure pVapour of the operating fluid.
- If p1 min ≤ pVapour + 50 mbar or operating conditions change (media, temperatures), consult the manufacturer.
- Process gas use must be ensured for cavitation protection if an explosive gas mixture could arise from ambient air entering.
Covers setting up the unit, mechanical connection of suction and discharge branches, connection of system components and ancillaries, and electrical motor connection. Requires pressure monitoring on the discharge side, compulsory monitoring of operating liquid feed and liquid level, and defines bleeder resistance requirements for ATEX.
- Drive motor type of protection must match ambient atmosphere per 2014/34/EU.
- Added equipment/components must meet device group II category requirements unless they have their own ignition source.
- Bleeder resistance of each accessory/attached part and of the unit must be < 10^6 Ohm to ground when assembled.
- Pressure monitoring G2 must be installed downstream of the gas output flange; unit must switch off if p2 max is exceeded.
- Suction line must have bleeder resistance < 10^6 Ohm if operating with cavitation protection.
- Filters required if foreign bodies can enter during operation or standstill.
- Monitoring systems must be fully functional independently of one another, also with computer-programmed controls.
Defines compulsory monitoring of continual operating liquid feed and liquid level before start-up, with alternative sensor principles and disconnection conditions. Figure 1 defines measuring point positions F1–F5, G1, G2 and drain tappings A, B, C for 2BV20.. and 2BV51.. units.
- Operating liquid feed monitoring compulsory; alternative a) volume flow F1 with disconnection at ≤ 50 % of design operating fluid flow.
- Alternative b) operating fluid temperature F2 (drain tapping) or F5 (housing) with disconnection at ≥ 60 °C (140 °F).
- Blockable volume flow devices require an additional redundant monitoring system.
- Liquid level monitoring before start-up compulsory; sensors may be inductive proximity switches, solenoid-operated sensors or pressure-dependent sensors.
- Unit may only be switched on if fluid level is between hf min and hf max.
- Monitoring devices must be suitable/certified for the disconnection conditions and their installation category; EN ISO 13849 implementation recommended.
- Sensors in direct contact with internal space must be non-corrosive and certified for category 2.
Table of minimum and maximum operating liquid levels hf min / hf max per pump type, used as the switch-on condition for the liquid level monitoring. The liquid level monitoring device includes a shut-off valve that opens after switch-off and closes before start-up after level regulation.
- 2BV2060: hf min 75 mm (2.95 in), hf max 95 mm (3.74 in).
- 2BV2061 / 2BV2070: hf min 95 mm (3.74 in), hf max 120 mm (4.72 in).
- 2BV2071 / 2BV5110: hf min 116 mm (4.57 in), hf max 156 mm (6.14 in).
- 2BV5111 / 2BV5121: hf min 130 mm (5.12 in), hf max 170 mm (6.69 in).
- 2BV5131: hf min 140 mm (5.51 in), hf max 185 mm (7.28 in).
- 2BV5161: hf min 175 mm (6.89 in), hf max 235 mm (9.25 in).
- If venting to atmosphere is not possible, route the line back into the equipment behind the shut-off valve on the suction side.
ATEX assessment of accessories: stainless steel operating fluid separators 2BX1 102, 2BX2 103 and 2BX1 107, metal check valves 2BY6 9-type and metal gas ejectors 2BP5-type do not fall under 2014/34/EU because they have no own ignition sources. Bleeder resistance < 10^6 Ohm to ground is required for each when attached or installed.
- Separators 2BX1 102, 2BX2 103, 2BX1 107: no own ignition sources; propellant gas and operating fluid must not react chemically with the separator.
- Suction-side separator must be a pressure-resistant construction per 2014/68/EU; standard catalogue separator must not be used.
- Check valves 2BY6 9-type: no own ignition sources; bleeder resistance < 10^6 Ohm to ground.
- Gas ejectors 2BP5-type: no own ignition sources; bleeder resistance < 10^6 Ohm to ground; gas propellant must be free of statically rechargeable particles.
Requires strict adherence to the accompanying drive motor operating manual. Operation of the unit with a frequency converter is explicitly not permitted.
- Follow the drive motor operating manual strictly.
- Operation with a frequency converter is not permitted.
If a monitoring system shuts the unit down during operation, the cause must be identified and the problem rectified before restarting. The safety level required by the device category must not be reduced.
- Identify and rectify cause of any monitoring-triggered shutdown before restart.
- Do not go below the safety level required by the device category.
Defines operator-permitted maintenance and service intervals. The operator may not carry out maintenance, servicing or repair work requiring dismantling of the machine. Weekly dust removal and ball bearing service every 2 years or 18,000 operating hours.
- Weekly: remove dust deposits from unit.
- Every 2 years or 18,000 operating hours: ball bearings replaced or re-greased by service technician.
- No operator maintenance, servicing or repair requiring dismantling.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Operating liquid temperature limits are min +5 °C (+41 °F), nominal +15 °C (+59 °F), max +65 °C (+149 °F). p.5 ↗ | Cooling/feed systems must keep the operating liquid within this window; nominal +15 °C is the design point. | L-BV2 | L-BV5 ATEX series |
| Suction pressure p1 min must be at least 50 mbar above the vapour pressure pVapour of the operating fluid. p.5 ↗ | If p1 min ≤ pVapour + 50 mbar or media/temperatures change, the manufacturer must be consulted; otherwise cavitation risk. | L-BV2 | L-BV5 ATEX series |
| Operating liquid feed monitoring disconnection condition: volume flow ≤ 50 % of the design operating fluid flow. p.5 ↗ | Flow monitor F1 must be set to trip at half the design flow; blockable flow devices need a redundant monitoring system. | L-BV2 | L-BV5 ATEX series |
| Operating fluid temperature monitoring disconnection condition: temperature ≥ 60 °C (140 °F) measured at drain tapping F2 or housing F5. p.6 ↗ | Temperature sensors must be set to shut down the unit at 60 °C to protect the slide ring seal. | L-BV2 | L-BV5 ATEX series |
| Bleeder resistance for each installed accessory or attached part and for the unit must be < 10^6 Ohm to ground when assembled. p.5 ↗ | Earthing/bonding must be verified after assembly to avoid electrostatic ignition hazards. | L-BV2 | L-BV5 ATEX series and ancillaries |
| Pressure monitoring G2 must be installed downstream of the unit's gas output flange and must switch off the unit if p2 max from base manual section 3.3 is exceeded. p.5 ↗ | Discharge-side throttling overload protection is mandatory and must act directly on the unit. | L-BV2 | L-BV5 ATEX series |
| Operating liquid level switch-on window hf min/hf max: 2BV2060 75/95 mm; 2BV2061 and 2BV2070 95/120 mm; 2BV2071 and 2BV5110 116/156 mm; 2BV5111 and 2BV5121 130/170 mm; 2BV5131 140/185 mm; 2BV5161 175/235 mm. p.7 ↗ | Liquid level monitoring must only permit start-up when the level lies between these values. | Per type as listed |
| Operating liquid ignition temperature must be above 150 °C. p.4 ↗ | Selection of the operating fluid must respect this ATEX limit; normally water with pH 6 to 9. | L-BV2 | L-BV5 ATEX series |
| Operating fluids with heat capacity < 3 kJ/kg K or boiling point not 20 K above the input temperature require manufacturer consultation. p.4 ↗ | Non-water fluids must be checked against these thresholds before use. | L-BV2 | L-BV5 ATEX series |
| ATEX classification: internal space category 2G, temperature class T4; surrounding area temperature class T3 if maximum temperatures are complied with; marking II 2G Ex h IIC T3 Gb (option F91). p.3 ↗ | Installation is permitted only in areas where explosive gas/vapour atmospheres occur occasionally; zones 0, 20, 21 and 22 are forbidden. | L-BV2 | L-BV5 ATEX series |
| Operation with a frequency converter is not permitted. p.8 ↗ | Motor must be connected directly to the supply; VFD-driven operation is a forbidden misuse. | L-BV2 | L-BV5 ATEX series |
| Monitoring systems must be fully functional independently of one another, including when computer-programmed controls are used; EN ISO 13849 implementation is recommended. p.5 ↗ | Do not share a single controller path for liquid feed and liquid level monitoring; design for independence. | L-BV2 | L-BV5 ATEX series |
| Liquid level sensors in direct contact with the internal space must be non-corrosive and certified for category 2. p.6 ↗ | Sensor selection must match the ATEX category of the measuring point. | L-BV2 | L-BV5 ATEX series |
| Suction-side separator must be a pressure-resistant construction per 2014/68/EU; the standard catalogue separator must not be used. p.8 ↗ | When a suction-side separator is required, specify a pressure-resistant variant instead of the standard 2BX separator. | Units with suction-side separator |
| Gas ejector propellant must be free of statically rechargeable particles. p.8 ↗ | Propellant gas supply must be filtered/conditioned to avoid electrostatic charging. | Units with 2BP5-type gas ejector |
| Maintenance intervals: weekly dust removal; ball bearings replaced or re-greased every 2 years or 18,000 operating hours by a service technician. p.8 ↗ | Plan service intervals accordingly; operator may not perform dismantling work. | L-BV2 | L-BV5 ATEX series |
| If foreign bodies can enter during operation or standstill, suitable filters must be attached; gases/vapours must be free of solid matter. p.5 ↗ | Suction-side filtration is required where ingress risk exists. | L-BV2 | L-BV5 ATEX series |
| Higher corrosion-resistance and hygiene construction is available only for 2BV2070, 2BV2071 and 2BV5.. types. p.3 ↗ | For aggressive/hygienic duties, only these types can be specified in the corrosion-resistant construction. | 2BV2070, 2BV2071, 2BV5.. |