BINDER BD 23
BINDER BD 23 — Incubators with Temperature 5…100 °C.
The BD 23 is a 20 L natural-convection incubator in BINDER's BD series, configured as the 230 V/50 Hz standard variant (BD023-230V, Art. 9010-0187) with a CEE 7/7 plug. It covers +5 to 100 °C with 0.2 K fluctuation and 0.5 K uniformity, reaching 100 °C in 59 min. It serves as a compact benchtop unit for temperature-controlled incubation where forced-air circulation is not required.
Direct drop-in replacements
BINDER BD Series — Model Comparison & Selection
Full specifications
| Temperature | 5...100 °C |
| Heating-up time to 100 °C | 59 min |
| Interior volume | 20 L |
| Load per rack | 12 kg |
| Nominal power | 0.2 kW |
| Permitted load | 25 kg (BD023-230V) |
| Temperature fluctuation | 0.2 K |
| Temperature uniformity | 0.5 K |
| Back wall clearance | 100 mm (BD023-230V) |
| Side wall clearance | 50 mm (BD023-230V) |
| Article Number mfr | 9010 |
| Recovery time after door was opened for 30 s at 37°C mfr | 20 min |
| Depth | 520 mm (BD023-230V) |
| Height | 495 mm (BD023-230V) |
| Interior width | 222 mm (BD023-230V) |
| Width | 435 mm (BD023-230V) |
| Net weight of the unit (empty) mfr | 27 kg |
| Power frequency | 50 Hz |
| Rated voltage | 230 V |
| Unit fuse | 12.5 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- Natural-convection (gravity) chamber, 20 L interior, net interior dimensions 222 × 495 × 520 mm (W×H×D); exterior width 435 mm, empty weight 27 kg.
- This is the smallest chamber in the BD series; siblings BD 56, BD 115, BD 260 and BD 400 share the same +5 to 100 °C range but offer larger interiors. Choose BD 23 when bench space and sample batch size are the binding constraints.
- Two electrical variants exist: BD023-230V (230 V 1~, 50/60 Hz, CEE 7/7) and BD023UL-120V (120 V 1~, 60 Hz, NEMA 5-15). The facts here describe the 230 V variant only.
Behavior under load
- Temperature fluctuation 0.2 K and uniformity 0.5 K define the working tolerance across the chamber; no fan means these figures depend on loading pattern and free air movement, so avoid blocking the chamber floor and rear.
- Heating-up time to 100 °C is 59 min; recovery after a 30 s door opening at 37 °C is 20 min — relevant when sizing door-opening frequency in a protocol.
- Permitted load 25 kg total, 12 kg per rack; nominal power 0.2 kW.
Installation and operation
- Wall clearance: 100 mm at the rear, 50 mm at the sides; the unit is fused at 12.5 A.
- No digitized curve points or application/certification data were supplied; performance statements above are limited to the factory specification values.
Integration & Operating Notes
The BD023-230V is a single-phase 230 V unit drawing 0.2 kW nominal and protected by a 12.5 A fuse; the supply circuit and outlet must be rated accordingly. The 120 V/60 Hz UL variant (BD023UL-120V, NEMA 5-15) is a separate article and cannot be substituted on a 230 V installation.
The chamber relies on natural convection and passive heat exchange with the room; insufficient rear or side clearance compromises the 0.5 K uniformity figure and can overheat the housing. Plan bench depth for the 520 mm interior depth plus the 100 mm rear gap.
With 0.2 K fluctuation and 0.5 K uniformity specified, the 25 kg total / 12 kg per-rack load limits and free air paths must be maintained; dense or floor-covering loads block gravity circulation and lengthen the 20 min recovery after a 30 s door opening at 37 °C.
Selection & Integration Q&A
Pick BD 23 for small batches on a crowded bench: 20 L interior, 435 mm exterior width, 27 kg. Move to a sibling when sample count or rack area exceeds the 25 kg total / 12 kg per-rack load; all siblings share the +5 to 100 °C range, so the decision is purely chamber size and load capacity.
The BD023-230V needs single-phase 230 V, 50/60 Hz, 0.2 kW nominal, on a circuit with 12.5 A fuse protection and a CEE 7/7 outlet. The BD023UL-120V is a distinct article (120 V, 60 Hz, NEMA 5-15) and is not interchangeable on a 230 V supply.
Allow 100 mm behind and 50 mm at each side for natural-convection heat exchange. Keep loads within 25 kg total and 12 kg per rack and avoid blocking air paths; otherwise the specified 0.5 K uniformity and 20 min recovery at 37 °C after a 30 s door opening will not be met.
The standard scope covers the unit only; racks, stacking accessories and calibration certificates are not included and must be ordered separately. Size the rack order against the 12 kg per-rack limit and the 25 kg total load before installation.