Peter Huber Kältemaschinenbau Minichiller 1000 OLÉ Kompakter
Peter Huber Kältemaschinenbau Minichiller 1000 OLÉ Kompakter — Recirculating chillers.
The Minichiller 1000 OLÉ Kompakter is a compact recirculating chiller with a pressure/suction pump and OLED controller, covering -20 to 40 °C. Its fixed-speed pump delivers up to 24 l/min at 0.7 bar, distinguishing it from the speed-controlled 'P' variants. It serves closed-loop cooling of laboratory and industrial processes requiring a small footprint.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 1000 OLÉ Kompakter Current | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600-H OLÉ Kompakter | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600 OLÉ Kompakter | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Maximum delivery flow rate | 24 l/min (pressure pump; 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure- and suction pump |
| Temperature range | -20...40 °C |
| Weight | 36 kg |
| Current consumption | 4 A (max) |
| Fuse rating | 16 A |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Refrigerant | R-1270 (A3, H220) (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Maximum return flow temperature | 80 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The Minichiller 1000 OLÉ Kompakter is the base fixed-speed pump variant of the 1000 series; siblings include the 1000-H (heater) and 1000w-H (heater, wider) versions, as well as their OLÉ counterparts.
- Unlike models with 'P' in the name, this unit is not specifically intended for applications with high pressure drop; the pump speed is not adjustable.
- The refrigerant is R-1270 (A3, H220), a flammable natural refrigerant with GWP 0, requiring attention to room volume and ignition sources.
Behavior and media
- Temperature range is -20 to 40 °C, with a maximum return-line temperature of 80 °C.
- The pressure- and suction pump provides a maximum delivery flow rate of 24 l/min at 0.7 bar; whisper mode reduces this to 14 l/min and 0.2 bar for noise-sensitive installations.
- The plastic circulation pump is not resistant to acetone or polyglycols; these fluids require the optional more resistant pump.
- For freeze protection below 0 °C, water must be mixed with glysantine or ethylene glycol.
Installation, control and operation
- The unit requires a 208-240 V 1~/2~ 50/60 Hz supply with maximum current 4 A; a country-specific plug must be specified at order.
- Control is via the OLÉ controller with OLED display and 0.1 K resolution; interfaces include USB (Device) and RS232.
- Pump connection is M16x1 male; hose connector NW12 and sleeve nuts M16x1 are included.
- A minimum filling capacity of 2.8 l of heat transfer fluid is required.
- The unit must not be installed in an ATEX zone; a drip tray for condensation water and thermal fluid must be installed below the unit.
Integration & Operating Notes
Operation within a hazardous area can cause explosion due to the flammable R-1270 refrigerant and electrical components. Site the chiller in a non-classified area with adequate ventilation and no ignition sources.
Condensation water and thermal fluid can escape from connections or during maintenance. A drip tray must be installed below the temperature control unit to contain leaks and protect the floor.
Condensation can form at the cooling water connections and drip onto cables. Electrical lines directly below the unit must be protected against liquid ingress to prevent shock hazard.
Higher return temperatures can damage the chiller or invalidate safe operation. Ensure the application's heat load and flow rate keep the return line at or below 80 °C.
Sea water must not be used for water cooling. If salts such as chlorides or bromide are added to the water circuit, anti-corrosion agents are mandatory to prevent corrosion damage.
The standard plastic circulation pump is not resistant to acetone and polyglycols (depending on the manufacturer). These fluids require the optional more resistant pump to avoid pump damage.
A combination such as -5% voltage with +2% frequency is not allowed. Verify that the supply remains within EN60034-1 limits under all operating conditions to avoid invalid operation.
Single/two-phase units are supplied with a power cable and country-specific plug. The plug type must be stated when ordering; otherwise the unit may arrive without a suitable plug for the site.
A drain valve (#6839) is available as an optional accessory to simplify draining of the heat transfer fluid. Order it with the unit if regular fluid changes or maintenance draining are planned.
Selection & Integration Q&A
Choose this base model for cooling-only duty with a fixed-speed pump and no heater. The 1000-H adds heating; the 1000w-H offers a wider variant. Select a 'P' model if your application has high pressure drop, since this unit's pump speed is not adjustable.
The pump connection is M16x1 male; hose connector NW12 and sleeve nuts M16x1 are included. Do not install valves or quick-release couplings in the feed/discharge lines. Ensure at least 2.8 l filling capacity and use a drip tray below the unit.
Ambient temperature must be 5–40 °C. Do not install in an ATEX zone. Electrical lines below the unit must be protected from liquid. Cooling capacity drops as ambient temperature rises, so size with margin in warm rooms.
The drain valve (#6839) is optional. A country-specific plug must be specified at order. Anti-corrosion agents are required if salts are added to the water circuit. No maintenance schedule is detailed in the provided digests; refer to the manual's Service and Maintenance section.