Peter Huber Kältemaschinenbau Minichiller 1200 OLÉ Kompakter
Peter Huber Kältemaschinenbau Minichiller 1200 OLÉ Kompakter — Recirculating chillers.
The Minichiller 1200 OLÉ Kompakter is a compact recirculating chiller with a pressure/suction pump and OLED controller, rated for -20 to 40 °C with an 80 °C return-line allowance. Its 24 l/min pump and M16x1 connections distinguish it within the Minichiller series, serving laboratory and industrial cooling circuits.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 1200 OLÉ Kompakter Current | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600-H OLÉ Kompakter | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600 OLÉ Kompakter | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Maximum delivery flow rate | 24 l/min (max.; pressure pump, 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure- and suction pump |
| Temperature range | -20...40 °C |
| Weight | 36 kg (net) |
| Current consumption | 5 A (max.) |
| Fuse rating | 16 A |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Ambient temperature limit | 5...40 °C |
| Maximum return flow temperature | 80 °C (max.) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The Minichiller 1200 OLÉ Kompakter is a compact recirculating chiller from the Minichiller series, equipped with an OLÉ controller and OLED display. It uses a pressure- and suction pump with a maximum delivery flow rate of 24 l/min at 0.7 bar, and pump connections are M16x1 male. The pump speed is not adjustable. The unit weighs 36 kg net and is rated IP20. Within the series, sibling models such as the Minichiller 1000-H, 1000-H OLÉ, 1000 OLÉ, and 1000w-H Kompakter differ in configuration; this 1200 OLÉ variant is distinguished by its controller and pump characteristics.
Operating envelope and media behavior
The operating temperature range is -20 to 40 °C, with a maximum return-flow temperature of 80 °C, allowing higher return temperatures from the application. The refrigerant is R-1270 (A3, H220), a flammable natural refrigerant, so installation must consider A3 safety requirements. The plastic pump is not resistant to acetone or polyglycols; for freeze protection, water should be mixed with glysantine or ethylene glycol. Cooling capacity is specified at 20 °C room temperature and may drop at higher ambient temperatures. The unit is EMC-classified Class A, Group 1 to EN55011, intended for industrial environments.
Installation, control and operation
The unit requires a 208-240 V 1~/2~ 50/60 Hz supply with a maximum current of 5 A and a 16 A fuse. Voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not allowed. Single- and two-phase devices are delivered with a power cable and country-specific plug (specify when ordering). The pump connection is M16x1 male; included accessories are hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover. The unit must not be installed in an ATEX zone, and a drip tray for condensation water and thermal fluid must be installed below the unit. Electrical lines directly below the unit must be protected against liquid ingress. Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used. Do not install valves or quick-release couplings in the feed/discharge lines. The unit has USB (Device) and RS232 interfaces. Whisper mode reduces sound pressure to 51 dB(A) ±4 dB(A) but also reduces pump delivery to 14 l/min at 0.2 bar.
Integration & Operating Notes
The unit must not be installed or started within an ATEX zone because operation there can cause explosion. A condensation water and thermal fluid drip tray must be installed below the unit by the responsible body. Electrical lines directly below the unit must be protected against liquid ingress due to possible condensation.
The 208-240 V 1~/2~ 50/60 Hz supply must respect ±5% voltage and ±2% frequency tolerances, but the combination of -5% voltage with +2% frequency is explicitly not allowed. The maximum current is 5 A and a 16 A fuse is required. The country-specific plug must be specified at ordering.
The plastic pump is not resistant to acetone or polyglycols (depending on the manufacturer), so these fluids must be avoided or a more resistant pump specified. For freeze protection, water should be mixed with glysantine or ethylene glycol. Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used.
Do not install valves or quick-release couplings in the feed/discharge lines from the temperature control unit to the application and from the application to the temperature control unit. This avoids overpressure damage, especially to glass apparatus. The pump connection is M16x1 male; included accessories are hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover.
Whisper mode reduces sound pressure to 51 dB(A) ±4 dB(A) but also reduces pump delivery to 14 l/min at 0.2 bar, compared to the maximum 24 l/min at 0.7 bar. This trade-off must be considered when sizing the circuit for quiet operation.
The refrigerant is R-1270 (A3, H220), a flammable natural refrigerant. The installation location must be assessed for A3 refrigerant safety requirements, including checking the refrigerant charge against room size to avoid exceeding the limit value per m³ of ambient air.
Selection & Integration Q&A
Choose the 1200 OLÉ when you need the OLÉ controller with OLED display and a pressure/suction pump delivering up to 24 l/min at 0.7 bar. Sibling models differ in configuration; the 1000-H variants may include heating, while the 1200 OLÉ is cooling-only with an 80 °C return allowance. Select based on required cooling capacity and pump curve.
The pump connection is M16x1 male; included accessories are hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover. Do not install valves or quick-release couplings in the feed/discharge lines. Ensure the plastic pump is compatible with your fluid; avoid acetone and polyglycols. Use drinking water or filtered river/sea water for cooling, never sea water.
The unit is rated IP20 and must be operated between 5 °C and 40 °C ambient in a dry, protected location. It must not be installed in an ATEX zone. A drip tray for condensation water and thermal fluid must be installed below the unit. Electrical lines below the unit must be protected against liquid ingress. Cooling capacity is specified at 20 °C room temperature and may drop at higher ambient.
The base delivery includes hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover, plus a power cable with country-specific plug (specify at ordering). Anti-corrosion agents are mandatory if salts such as chlorides or bromide are added to the water circuit. For freeze protection, mix water with glysantine or ethylene glycol. Regular maintenance per the manual is required; service intervals are detailed in the Operation Manual.