The Minichiller 300 OLÉ Kompakter is a compact recirculating chiller with a pressure-and-suction pump and OLED display, covering -20 to 40 °C with 0.3 kW cooling at 15 °C. It is the smallest OLÉ-controlled variant in the series, distinguished from the 1000-series siblings by its 0.3 kW capacity. It serves as a point-of-use cooling source for laboratory and industrial circuits requiring sub-ambient temperature control.

Noise level
53 dB

Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Minichiller 300 OLÉ Kompakter Current 53OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 1000 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1000w-H Kompakter —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Minichiller 1000w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1000w Kompakter —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Minichiller 1200-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1200 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1200w-H Kompakter —Pilot ONEIII / FL-20–100——
Minichiller 1200w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 280 OLÉ Kompakter 53OLÉI / NFL-5–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300w-H OLÉ Kompakter 51OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300w OLÉ Kompakter 53OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 600-H OLÉ Kompakter 56OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 600 Kompakter —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D110-120V 1~ 60Hz
Minichiller 600 OLÉ Kompakter 56OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 60Hz
Minichiller 600w OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 800 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 800w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz

Full specifications

Core Performance & Functional Specifications
Noise level 53 dB(A)
Pump connection M16x1 AG male
Pump speed adjustable no
Pump type Pressure- and suction pump
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 23 kg
Electrical, Power & Drive Specifications
Power supply 220-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Maximum return flow temperature 80 °C
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Thermal behavior and media

Installation, control and operation

Integration & Operating Notes

Mounting
Install only in non-ATEX area with drip tray below

The unit must not be installed or started within an ATEX zone because operation there can cause explosion. A condensation water / thermal fluid drip tray must be installed below the temperature control unit by the responsible body. Electrical lines directly below the unit must be protected against liquid ingress.

Minichiller Operation Manual, pages 13, 15, 28
Electrical
Supply must stay within ±5 % voltage and ±2 % frequency

The combination of -5 % voltage and +2 % frequency is not allowed. The supply must be 220–240 V, 1~/2~, 50/60 Hz. Minimum fuse 10 A, maximum fuse 16 A at 2.8 A max current. A country-specific plug must be specified when ordering.

Minichiller 300 OLÉ Datasheet, page 2
Process Limits
Cooling capacity drops to 0.07 kW at -20 °C

Cooling capacity is 0.3 kW at 15 °C, 0.2 kW at 0 °C, 0.14 kW at -10 °C, and 0.07 kW at -20 °C. The load must be checked at the lowest operating temperature. Rated output data are valid at 20 °C room temperature; higher ambient temperatures reduce capacity.

Minichiller 300 OLÉ Datasheet, pages 1–2
Cooling & Media
Plastic pump incompatible with acetone and polyglycols

The plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). For sub-zero operation, water should be mixed with glysantine or ethylene glycol for freeze protection. Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used.

Minichiller 300 OLÉ Datasheet, page 2; Minichiller Operation Manual, page 28
Maintenance
Anti-corrosion agents mandatory if salts added to water circuit

The addition of anti-corrosion agents is mandatory if salts such as chlorides or bromide have been added to the water circuit. The refrigerant charge is 0.041 kg with GWP 0.02, giving a CO2 equivalent of 0.0 t, which simplifies leak-check and F-gas documentation obligations.

Minichiller Operation Manual, page 28; Minichiller 300 OLÉ Datasheet, page 1
Control & I/O
Pt100 input displays but does not control process temperature

The optional Pt100 sensor input only displays the process temperature and does not control it. The OLÉ controller provides an OLED display with 0.1 K resolution, USB (device) and RS232 interfaces. The pump speed is not adjustable.

Minichiller 300 OLÉ Datasheet, page 1

Selection & Integration Q&A

When should I choose the Minichiller 300 OLÉ Kompakter instead of a 1000-series sibling?

Choose the 300 when your heat load at the lowest operating temperature is below 0.07 kW at -20 °C or 0.3 kW at 15 °C. The 1000-series siblings offer higher cooling capacity for larger loads; the 300 is the smallest OLÉ-controlled variant.

What piping and fittings are required to connect the application to the pump?

The pump connection is M16x1 male; a hose connector NW12 and M16x1 sleeve nuts are included. Do not install valves or quick-release couplings in the feed/discharge lines to the application. Ensure the circuit can withstand the pump pressure.

What maintenance and accessories are needed beyond the base delivery?

Anti-corrosion agents are mandatory if salts are added to the water circuit. For sub-zero use, mix water with glysantine or ethylene glycol. A country-specific plug must be specified at ordering. The Pt100 sensor is optional and only displays temperature.