Peter Huber Kältemaschinenbau Minichiller 600 OLÉ Kompakter
Peter Huber Kältemaschinenbau Minichiller 600 OLÉ Kompakter — Recirculating chillers with Noise level 56 dB.
The Minichiller 600 OLÉ Kompakter is a compact recirculating chiller with a pressure/suction pump and OLÉ controller, covering -20 to 40 °C with an 80 °C maximum return temperature. It is distinguished within the Minichiller series by its 600-size cooling capacity and OLÉ interface (USB/RS232), while the 1000-series siblings offer larger capacity. It serves as a point-of-use cooling source for laboratory and industrial circuits requiring stable temperature control.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 600 OLÉ Kompakter Current | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 1000 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600-H OLÉ Kompakter | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Noise level | 56 dB(A) |
| Maximum delivery flow rate | 24 l/min (pressure pump; 0, 7 bar) suction pump; 0, 4 bar: 18 l/min |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure- and suction pump |
| Temperature range | -20...40 °C |
| Weight | 36 kg |
| Power supply | 110-120V 1~ 60Hz |
| Controller | OLÉ |
| Display resolution | 0, 1 K |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Maximum return flow temperature | 80 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and positioning
- Compact recirculating chiller using R-290 (A3, H220) refrigerant in the first stage; safety class I/NFL.
- OLÉ controller with OLED display, 0.1 K resolution, USB (Device) and RS232 interfaces.
- Pressure- and suction pump with M16x1 male connections; pump speed is not adjustable.
- Positioned in the Minichiller series below the 1000 and 1000-H variants, which provide higher cooling capacity; the 600 OLÉ is the smaller-capacity OLÉ-equipped model.
Performance and media
- Temperature range -20 to 40 °C; maximum return-line temperature 80 °C.
- Pump delivers up to 18 l/min at 0.4 bar in suction mode and 24 l/min at 0.7 bar in pressure mode.
- Cooling capacity is rated at 20 °C room temperature and derates as ambient temperature rises.
- Plastic pump is not resistant to acetone or polyglycols; freeze protection requires glycol/water mixture.
- Whisper mode reduces sound pressure to 51 dB(A) but limits pump delivery to 14 l/min and 0.2 bar.
Installation and operation
- Requires 110-120 V 1~ 60 Hz supply, 8.5 A max, 10 A fuse; voltage tolerance ±5% with frequency ±2%.
- IP20 protection; ambient 5-40 °C; must not be installed in ATEX zones.
- Drip tray required below unit; electrical lines below must be protected from liquid ingress.
- Cooling water must be drinking water or filtered river/sea water; sea water prohibited.
- Do not install valves or quick-release couplings in feed/discharge lines.
- Minimum filling capacity 2.8 l; expansion tank 2.2 l.
- EMC Class A Group 1; may cause interference in residential areas.
Integration & Operating Notes
Condensation and thermal fluid can escape from the chiller, so a drip tray must be installed below the unit and any electrical lines directly underneath must be protected against liquid ingress to prevent shock hazard.
The permissible return-line temperature is 80 °C; exceeding this limit can damage the chiller or trip alarms, so the process heat load returned to the unit must be checked against this value.
The unit draws up to 8.5 A and requires a minimum 10 A fuse; voltage tolerance is ±5% only with simultaneous frequency tolerance of ±2%, and certain combinations are not allowed, so site power quality must be verified before connection.
The standard plastic pump is not resistant to acetone or polyglycols (depending on manufacturer), so these fluids must be avoided or a more resistant pump specified to prevent premature failure and leaks.
Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used. Anti-corrosion agents are mandatory if salts such as chlorides or bromide are added to the water circuit.
The minimum filling capacity is 2.8 l and the expansion tank is 2.2 l; the heat-transfer fluid volume must be set accordingly, and for freeze protection water should be mixed with glysantine or ethylene glycol.
The OLÉ controller provides USB (Device) and RS232 interfaces for integration with external monitoring or control systems; the OLED display shows temperature with 0.1 K resolution.
Selection & Integration Q&A
Choose the 600 OLÉ when your heat load fits its smaller capacity and you need the OLÉ controller with USB/RS232. The 1000 and 1000-H variants offer higher cooling capacity for larger loads; select those if the 600's capacity is insufficient.
The pump connection is M16x1 male; hose connector NW12 and sleeve nuts M16x1 are included, so hoses must match this thread. A 110-120 V 1~ 60 Hz supply with 10 A fuse is required, and a country-specific plug must be specified at ordering.
Ambient temperature must be 5-40 °C, protection is IP20, and the unit must not be installed in an ATEX zone. A drip tray is required below the unit, and electrical lines underneath must be protected from liquid ingress.
The base delivery includes hose connector NW12 and sleeve nuts M16x1, but not the heat-transfer fluid; minimum filling is 2.8 l. For freeze protection, mix water with glysantine or ethylene glycol. Anti-corrosion agents are mandatory if salts are added to the water circuit.