Peter Huber Kältemaschinenbau Minichiller 1000w-H Kompakter
Peter Huber Kältemaschinenbau Minichiller 1000w-H Kompakter — Recirculating chillers.
The Minichiller 1000w-H Kompakter is a water-cooled recirculating chiller with a pressure/suction pump and Pilot ONE controller, covering -20 to 100 °C. Its 1 kW cooling capacity at +15 °C falls to 0.35 kW at -20 °C, so it suits low-temperature cooling of analytical or laboratory circuits where facility water is available. The 'w' denotes water cooling; the 'H' heater variant adds class III/FL overtemperature and low-level protection.
Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection
| Model | Noise level, dB | Controller | Safety class | Temperature range, °C | Interface | Power supply |
|---|---|---|---|---|---|---|
| Minichiller 1000w-H Kompakter Current | — | Pilot ONE | III / FL | -20–100 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1000w Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 1200w-H Kompakter | — | Pilot ONE | III / FL | -20–100 | — | — |
| Minichiller 1200w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 280 OLÉ Kompakter | 53 | OLÉ | I / NFL | -5–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300 OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w-H OLÉ Kompakter | 51 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 300w OLÉ Kompakter | 53 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 220-240V 1~/2~ 50/60Hz |
| Minichiller 600-H OLÉ Kompakter | 56 | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 600 Kompakter | — | Pilot ONE | I / NFL | -20–40 | Ethernet, USB (Host u. D | 110-120V 1~ 60Hz |
| Minichiller 600 OLÉ Kompakter | 56 | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 110-120V 1~ 60Hz |
| Minichiller 600w OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800 OLÉ Kompakter | — | OLÉ | I / NFL | -20–40 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
| Minichiller 800w-H OLÉ Kompakter | — | OLÉ | III / FL | -20–100 | USB (Device), RS232 Inte | 208-240V 1~/2~ 50/60Hz |
Full specifications
| Maximum delivery flow rate | 24 l/min (pressure pump max.; 0, 7 bar) |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure- and suction pump |
| External sensor connection | Pt100 |
| Temperature range | -20...100 °C |
| Weight | 40 kg |
| Current consumption | 12 A (max.) |
| Fuse rating | 16 A |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 3 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
The 1000w-H Kompakter is the water-cooled, heater-equipped member of the Minichiller 1000 compact series. Siblings include the air-cooled 1000-H and the OLÉ variants (1000 OLÉ, 1000-H OLÉ, 1000w-H OLÉ); this model is distinguished by water cooling ('w') and the heater ('H'), giving safety class III/FL with adjustable overtemperature protection and low-level protection. The refrigerant is R-290 (A3, H220), a flammable natural refrigerant, so room volume and ignition-source control must be checked against the charge on the rating plate.
Thermal behavior and media
Cooling capacity is strongly temperature-dependent: 1 kW at +15 °C, 0.8 kW at 0 °C, 0.55 kW at -10 °C and 0.35 kW at -20 °C. Selection must therefore be based on the lowest operating temperature, not the nominal figure. The pump is a speed-controlled pressure-and-suction type, adjustable to match the application; maximum delivery is 24 l/min at 0.7 bar. The plastic pump is not resistant to acetone or polyglycols. For freeze protection below 0 °C, water should be mixed with glysantine or ethylene glycol.
Installation, connection and control
Cooling water must be supplied at 5–20 °C with a differential pressure of at least 3 bar and a maximum pressure of 6 bar; below the dew point, pipes must be insulated. Cooling water connections are G1/2 male and pump connections M16x1 male. Electrical supply is 208–240 V, 1~ or 2~, 50/60 Hz, with maximum current 12 A and a 16 A fuse; voltage tolerance is ±5% and frequency ±2%, but -5% voltage combined with +2% frequency is not permitted. The Pilot ONE controller provides Ethernet, USB (host and device) and RS232 interfaces, plus a Pt100 external sensor connection. Protection rating is IP20, so a dry indoor location is required.
Integration & Operating Notes
Condensation and thermal fluid can escape from the unit, so a drip tray must be installed below it and any electrical lines directly underneath must be protected against liquid ingress. This prevents shock hazard and site contamination.
Facility cooling water outside this temperature range reduces capacity or causes condensation; differential pressure below 3 bar prevents proper operation, and pressure above 6 bar can damage the cooling circuit. Size the supply accordingly.
The supply must be 208–240 V at 50/60 Hz with ±5% voltage and ±2% frequency tolerance, but the combination of -5% voltage and +2% frequency is explicitly not allowed. Verify site quality before connection to avoid compressor or controller faults.
The unit uses R-290 (A3, H220), a flammable refrigerant. The charge on the rating plate and the room size must be checked so the refrigerant limit per m³ of ambient air is not exceeded; installation in an ATEX zone is prohibited.
Valves or quick-release couplings in the feed/discharge lines between the unit and the application can cause overpressure, especially with glass apparatus. Use unrestricted tubing runs and size the pump speed to the application pressure drop.
The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM. If chlorides or bromide are added to the water, anti-corrosion agents are mandatory; only drinking water or filtered river/sea water may be used, and sea water is not permitted.
Moving an operating chiller risks burns, freezing and escaping thermal fluid. Shut down and drain before relocation, and observe the ambient temperature range of 5–40 °C for reliable operation.
Selection & Integration Q&A
Choose the 1000w-H when facility cooling water (5–20 °C, 3–6 bar differential) is available and you need a heater with class III/FL protection. Air-cooled 1000-H suits sites without water; OLÉ variants differ in configuration and should be selected only if their specific features are required.
Supply cooling water at 5–20 °C with differential pressure 3–6 bar. Connections are G1/2 male for cooling water and M16x1 male for the pump circuit; provide matching hose adapters. Insulate pipes if water temperature is below the dew point.
Install indoors, dry, IP20 environment, ambient 5–40 °C, away from ATEX zones. Provide a drip tray and protect cables below. Verify refrigerant charge vs room volume. Electrical supply 208–240 V, 1~/2~, 50/60 Hz, max 12 A, 16 A fuse; avoid -5% voltage with +2% frequency.
Base delivery excludes fittings and hoses; order G1/2 and M16x1 adapters. Use anti-corrosion agents if salts are added; mix water with glysantine or ethylene glycol for freeze protection. The plastic pump is not resistant to acetone or polyglycols. Regular service per manual; no specific interval stated.