Peter Huber Kältemaschinenbau Minichiller 1200 OLÉ Kompakter
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Minichiller 1200 OLÉ Kompakter

Peter Huber Kältemaschinenbau Minichiller 1200 OLÉ Kompakter — Recirculating chillers.

The Minichiller 1200 OLÉ Kompakter is a compact recirculating chiller with a pressure/suction pump and OLED controller, rated for -20 to 40 °C with an 80 °C return-line allowance. Its 24 l/min pump and M16x1 connections distinguish it within the Minichiller series, serving laboratory and industrial cooling circuits.

Peter Huber Kältemaschinenbau Minichiller Series — Model Comparison & Selection

Model Noise level, dBControllerSafety classTemperature range, °CInterfacePower supply
Minichiller 1200 OLÉ Kompakter Current —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1000 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1000w-H Kompakter —Pilot ONEIII / FL-20–100Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Minichiller 1000w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1000w Kompakter —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D208-240V 1~/2~ 50/60Hz
Minichiller 1200-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 1200w-H Kompakter —Pilot ONEIII / FL-20–100——
Minichiller 1200w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 280 OLÉ Kompakter 53OLÉI / NFL-5–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300 OLÉ Kompakter 53OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300w-H OLÉ Kompakter 51OLÉIII / FL-20–100USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 300w OLÉ Kompakter 53OLÉI / NFL-20–40USB (Device), RS232 Inte220-240V 1~/2~ 50/60Hz
Minichiller 600-H OLÉ Kompakter 56OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 600 Kompakter —Pilot ONEI / NFL-20–40Ethernet, USB (Host u. D110-120V 1~ 60Hz
Minichiller 600 OLÉ Kompakter 56OLÉI / NFL-20–40USB (Device), RS232 Inte110-120V 1~ 60Hz
Minichiller 600w OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 800 OLÉ Kompakter —OLÉI / NFL-20–40USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz
Minichiller 800w-H OLÉ Kompakter —OLÉIII / FL-20–100USB (Device), RS232 Inte208-240V 1~/2~ 50/60Hz

Full specifications

Core Performance & Functional Specifications
Maximum delivery flow rate 24 l/min (max.; pressure pump, 0, 7 bar)
Pump connection M16x1 AG male
Pump speed adjustable no
Pump type Pressure- and suction pump
Temperature range -20...40 °C
Dimensions, Weight & Mechanical Design
Weight 36 kg (net)
Electrical, Power & Drive Specifications
Current consumption 5 A (max.)
Fuse rating 16 A
Power supply 208-240V 1~/2~ 50/60Hz
Interfaces, Connections & Control
Controller OLÉ
Display resolution 0, 1 K
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Maximum return flow temperature 80 °C (max.)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The Minichiller 1200 OLÉ Kompakter is a compact recirculating chiller from the Minichiller series, equipped with an OLÉ controller and OLED display. It uses a pressure- and suction pump with a maximum delivery flow rate of 24 l/min at 0.7 bar, and pump connections are M16x1 male. The pump speed is not adjustable. The unit weighs 36 kg net and is rated IP20. Within the series, sibling models such as the Minichiller 1000-H, 1000-H OLÉ, 1000 OLÉ, and 1000w-H Kompakter differ in configuration; this 1200 OLÉ variant is distinguished by its controller and pump characteristics.

Operating envelope and media behavior

The operating temperature range is -20 to 40 °C, with a maximum return-flow temperature of 80 °C, allowing higher return temperatures from the application. The refrigerant is R-1270 (A3, H220), a flammable natural refrigerant, so installation must consider A3 safety requirements. The plastic pump is not resistant to acetone or polyglycols; for freeze protection, water should be mixed with glysantine or ethylene glycol. Cooling capacity is specified at 20 °C room temperature and may drop at higher ambient temperatures. The unit is EMC-classified Class A, Group 1 to EN55011, intended for industrial environments.

Installation, control and operation

The unit requires a 208-240 V 1~/2~ 50/60 Hz supply with a maximum current of 5 A and a 16 A fuse. Voltage and frequency tolerances are ±5% and ±2%, but the combination of -5% voltage with +2% frequency is not allowed. Single- and two-phase devices are delivered with a power cable and country-specific plug (specify when ordering). The pump connection is M16x1 male; included accessories are hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover. The unit must not be installed in an ATEX zone, and a drip tray for condensation water and thermal fluid must be installed below the unit. Electrical lines directly below the unit must be protected against liquid ingress. Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used. Do not install valves or quick-release couplings in the feed/discharge lines. The unit has USB (Device) and RS232 interfaces. Whisper mode reduces sound pressure to 51 dB(A) ±4 dB(A) but also reduces pump delivery to 14 l/min at 0.2 bar.

Integration & Operating Notes

Mounting
Install below an ATEX-free zone with drip tray

The unit must not be installed or started within an ATEX zone because operation there can cause explosion. A condensation water and thermal fluid drip tray must be installed below the unit by the responsible body. Electrical lines directly below the unit must be protected against liquid ingress due to possible condensation.

Minichiller Operation Manual, pages 13, 15, 28
Electrical
Supply must stay within voltage/frequency envelope

The 208-240 V 1~/2~ 50/60 Hz supply must respect ±5% voltage and ±2% frequency tolerances, but the combination of -5% voltage with +2% frequency is explicitly not allowed. The maximum current is 5 A and a 16 A fuse is required. The country-specific plug must be specified at ordering.

Minichiller 1200 OLÉ Technical Data, pages 1-2
Process Limits
Avoid acetone and polyglycols with plastic pump

The plastic pump is not resistant to acetone or polyglycols (depending on the manufacturer), so these fluids must be avoided or a more resistant pump specified. For freeze protection, water should be mixed with glysantine or ethylene glycol. Only drinking water or filtered river/sea water may be used as cooling water; sea water must not be used.

Minichiller 1200 OLÉ Technical Data, page 2; Operation Manual, page 28
Installation
No valves or quick-release couplings in lines

Do not install valves or quick-release couplings in the feed/discharge lines from the temperature control unit to the application and from the application to the temperature control unit. This avoids overpressure damage, especially to glass apparatus. The pump connection is M16x1 male; included accessories are hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover.

Minichiller Operation Manual, page 31; Technical Data, page 2
Operation
Whisper mode trades flow for lower noise

Whisper mode reduces sound pressure to 51 dB(A) ±4 dB(A) but also reduces pump delivery to 14 l/min at 0.2 bar, compared to the maximum 24 l/min at 0.7 bar. This trade-off must be considered when sizing the circuit for quiet operation.

Minichiller 1200 OLÉ Technical Data, page 1
Safety
A3 refrigerant requires room assessment

The refrigerant is R-1270 (A3, H220), a flammable natural refrigerant. The installation location must be assessed for A3 refrigerant safety requirements, including checking the refrigerant charge against room size to avoid exceeding the limit value per m³ of ambient air.

Minichiller 1200 OLÉ Technical Data, page 1; Operation Manual, page 16

Selection & Integration Q&A

When should I choose the Minichiller 1200 OLÉ Kompakter instead of a sibling model like the 1000-H OLÉ or 1000w-H?

Choose the 1200 OLÉ when you need the OLÉ controller with OLED display and a pressure/suction pump delivering up to 24 l/min at 0.7 bar. Sibling models differ in configuration; the 1000-H variants may include heating, while the 1200 OLÉ is cooling-only with an 80 °C return allowance. Select based on required cooling capacity and pump curve.

What are the requirements for connecting the Minichiller 1200 OLÉ to my application circuit?

The pump connection is M16x1 male; included accessories are hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover. Do not install valves or quick-release couplings in the feed/discharge lines. Ensure the plastic pump is compatible with your fluid; avoid acetone and polyglycols. Use drinking water or filtered river/sea water for cooling, never sea water.

What are the ambient and installation limits for the Minichiller 1200 OLÉ?

The unit is rated IP20 and must be operated between 5 °C and 40 °C ambient in a dry, protected location. It must not be installed in an ATEX zone. A drip tray for condensation water and thermal fluid must be installed below the unit. Electrical lines below the unit must be protected against liquid ingress. Cooling capacity is specified at 20 °C room temperature and may drop at higher ambient.

What maintenance and accessories are required for the Minichiller 1200 OLÉ, and what is not included?

The base delivery includes hose connector NW12, sleeve nuts M16x1, blank plug, and expansion-vessel cover, plus a power cable with country-specific plug (specify at ordering). Anti-corrosion agents are mandatory if salts such as chlorides or bromide are added to the water circuit. For freeze protection, mix water with glysantine or ethylene glycol. Regular maintenance per the manual is required; service intervals are detailed in the Operation Manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Minichiller Operation Manual
Manual ·2,9 МБ ·84 pp.
View PDF
PDF
Minichiller 1200 OLÉ Technical Data
Datasheet ·104,0 КБ ·2 pp.
View PDF