BINDER FED 115
BINDER FED 115 — Drying ovens with Temperature 10…300 °C.
The FED 115 is a forced-convection drying and heating oven with enhanced timer functions, 116 L interior, and a 10–300 °C working range. Within the FED series it is the mid-size 230 V single-phase model (1.3 kW, 5.7 A), distinguished from the 720 by supply and from smaller sizes by usable volume. It serves precise tempering, drying, and heat treatment of non-flammable solids and bulk materials in laboratory and production processes.
BINDER FED Series — Model Comparison & Selection
Full specifications
| Temperature | 10...300 °C |
| Air change rate | 32 x/h |
| Heating time to 150°C | 18 min |
| Interior volume | 116 L |
| Load per rack | 30 kg (FED115-230V / FED115UL-120V) |
| Nominal power | 1.3 kW |
| Permitted load | 150 kg (FED115-230V / FED115UL-120V) |
| Temperature fluctuation | 0.3 K |
| Temperature uniformity | 1.2 K |
| Rear wall clearance | 160 mm (FED115-230V / FED115UL-120V) |
| Side wall clearance | 100 mm (FED115-230V / FED115UL-120V) |
| Article Number mfr | 9010 |
| Recovery time after door was opened for 30 s at 150°C mfr | 4 min |
| Depth | 605 mm (FED115-230V / FED115UL-120V) |
| Height | 705 mm (FED115-230V / FED115UL-120V) |
| Width | 710 mm (FED115-230V / FED115UL-120V) |
| Net weight of the unit (empty) mfr | 54 kg |
| Power frequency | 50 Hz |
| Rated voltage | 230 V |
| Unit fuse | 6.3 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The FED 115 uses forced convection (fan) with adjustable fan speed in 10 % steps, unlike the natural-convection ED series; it adds enhanced timer functions (Delayed Off, Temperature-dependent Delayed Off, Delayed On) compared with the FD series.
- Interior volume is 116 L with net dimensions 710 × 705 × 605 mm (W×H×D); empty weight 54 kg. It is the 115-size member of the FED family, between the 56 and 260 siblings; the 720 is a two-door, 400 V three-phase unit with internal 16 A breaker.
- Electrical: 230 V 1~ 50/60 Hz, nominal power 1.3 kW, nominal current 5.7 A, external chamber fuse 6.3 A time-lag (T) 5×20 mm / 250 V. The UL variant (FED115UL-120V) draws 11.7 A at 120 V.
Behavior under load and in operation
- Temperature range 10–300 °C; fluctuation 0.3 K, uniformity 1.2 K. Heating to 150 °C takes 18 min; recovery after 30 s door opening at 150 °C is 4 min.
- Air-change rate 32 x/h. Permitted load 150 kg total, 30 kg per rack. Loading must leave at least 10 % of interior dimensions as wall clearance and must not exceed half the usable volume to maintain airflow and uniformity.
- Overtemperature protection: class 1 device trips at 330 °C (FED 115); safety controller class 2.0 per DIN 12880, set-point range 10–300 °C (1 degree resolution). Set safety set-point 2–5 °C above process set-point.
Installation, control and operation
- Installation indoors on non-flammable surface; ambient 18–40 °C, max 70 % r.h. non-condensing, altitude ≤2000 m. Wall clearances: 160 mm rear, 100 mm side. IP 20; pollution degree 2, over-voltage category II.
- Controller R4 with 1-degree display; Ethernet standard on FED; USB for data recording. Fan speed set in 10 % steps. Timer functions include Delayed Off and temperature-dependent Delayed Off/Delayed On.
- Supply tolerance ±10 %; verify against type plate. Annual maintenance and electrical inspection required (EN 50678/VDE 0701, EN 50699/VDE 0702).
Integration & Operating Notes
The chamber must not be set in unventilated recesses. Rear clearance 160 mm and side clearance 100 mm are required for heat dissipation and airflow. Ambient must stay 18–40 °C and ≤70 % r.h. non-condensing; altitude ≤2000 m. IP 20 means no water protection—do not spill liquids.
Exceeding the load or filling more than half the usable volume prevents sufficient airflow and homogeneous temperature. Maintain at least 10 % of interior dimensions as wall clearance. Charging materials must be non-flammable and operating temperature below flash point; corrosive acids/halides are excluded.
The chamber must be maintained at least once a year by licensed electricians or BINDER-authorized personnel; warranty is void if non-authorized personnel perform maintenance. Annual repeat electrical inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 is required, plus a test before initial startup and after any repair. Replace door gasket only when cold.
For decontamination, the FED series can be hot-air sterilized at 190 °C for at least 30 minutes; all flammable goods must be removed first. Recommended cleaning agents are neutral cleaner art. 1002-0016 and disinfectant spray art. 1002-0022; do not use neutral cleaner on zinc-coated hinge parts or rear wall.
Selection & Integration Q&A
Choose the FED 115 for 116 L usable volume and 230 V single-phase supply (1.3 kW, 5.7 A). The FED 260 offers larger volume but also 230 V; the FED 720 requires 400 V three-phase, has a two-door design, and its max set-point depends on ambient temperature. Select the 115 when bench space and single-phase power are constraints.
The FED115-230V requires 230 V 1~ 50/60 Hz, nominal power 1.3 kW, current 5.7 A, with an external 6.3 A time-lag (T) 5×20 mm / 250 V fuse. Supply fluctuation must not exceed ±10 %. The UL variant needs 120 V 1~ 60 Hz, 11.7 A. Verify the type plate before connection.
Install indoors on a non-flammable surface with ambient 18–40 °C, max 70 % r.h. non-condensing, altitude ≤2000 m. Maintain 160 mm rear and 100 mm side clearance; do not install in unventilated recesses. IP 20 protects against solid objects >12.5 mm but not water. Supply tolerance ±10 %.
Annual maintenance by authorized personnel and annual electrical safety test per EN 50678/VDE 0701 and EN 50699/VDE 0702 are mandatory. Recommended consumables: neutral cleaner art. 1002-0016, disinfectant spray art. 1002-0022. Optional accessories include APT-COM 4 software, Pt100 sensor, analog output, HEPA filter, and inert gas connection. Ethernet is standard; USB for data recording.