BINDER KB 260 — Incubators with Temperature 0…70 °C.
The BINDER KB 260 is a 262 L cooling incubator with a 0–70 °C working range, 0.1 K fluctuation and 0.2 K uniformity, housed in a 930 mm wide cabinet. It is the mid-series 260 L modification, distinguished from smaller KB 65/130 and larger KB 470/1060 siblings by its 656 mm interior width and 200 kg permitted load. It serves as a temperature-controlled culture and storage chamber in laboratory workflows requiring stable, uniform conditions.
Direct drop-in replacements
BINDER KB Series — Model Comparison & Selection
Full specifications
| Temperature | 0...70 °C |
| Interior volume | 262 L |
| Load per rack | 40 kg |
| Max. heat compensation | 410 W |
| Nominal power | 1.3 kW |
| Permitted load | 200 kg (KB260-230V / KB260UL-120V) |
| Temperature fluctuation | 0.1 K |
| Temperature uniformity | 0.2 K |
| Back wall clearance | 100 mm (KB260-230V / KB260UL-120V) |
| Side wall clearance | 180 mm (KB260-230V / KB260UL-120V) |
| Article Number mfr | 9020 |
| Recovery time after door was opened for 30 s at 37°C mfr | 3 min |
| Depth | 900 mm (KB260-230V / KB260UL-120V) |
| Height | 1396 mm (KB260-230V / KB260UL-120V) |
| Interior width | 656 mm (KB260-230V / KB260UL-120V) |
| Width | 930 mm (KB260-230V / KB260UL-120V) |
| Net weight of the unit (empty) mfr | 174 kg |
| Power frequency | 50 Hz |
| Rated voltage | 220...240 V |
| Unit fuse | 16.0 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- The KB 260 is a single-phase (1~, 50 Hz) cooling incubator rated 220–240 V, 1.3 kW nominal, protected by a 16.0 A unit fuse.
- Interior volume is 262 L with a net interior width of 656 mm; net cabinet dimensions are 930 mm wide × 1,396 mm high × 900 mm deep, and the empty unit weighs 174 kg.
- Within the KB series, the 260 sits between the KB 130 and KB 470; all siblings share the 0–70 °C range, so the choice is driven by chamber volume and load rather than temperature capability.
- The permitted load is 200 kg, with a maximum of 40 kg per rack, and the unit can compensate up to 410 W of heat input.
Thermal behavior
- Temperature fluctuation is 0.1 K and uniformity 0.2 K across the 0–70 °C range, supporting stable incubation conditions.
- Recovery time after a 30 s door opening at 37 °C is 3 minutes, which matters for frequent-access protocols.
- The 410 W maximum heat compensation defines the limit for active loads (e.g., equipment or organisms generating heat) placed inside the chamber.
Installation and operation
- Required clearances are 100 mm at the rear and 180 mm at the sides for heat dispersal; the unit must not be installed in unventilated recesses.
- The data sheet lists two variants: KB260-230V (CEE 7/7 plug, Art.-No. 9020-0473) and KB260UL-120V (NEMA 5-20 plug, Art.-No. 9020-0501); the 230 V variant is the one covered by the 220–240 V rating above.
- The attached LED plant light module digest describes an accessory with its own independent controller; it is not part of the base KB 260 delivery and, if used, adds up to 220 W of heat at full output that must be compensated within the 410 W budget.
Integration & Operating Notes
The cabinet dissipates heat through its surfaces; violating the prescribed rear and side distances or installing it in an unventilated recess prevents heat dispersal and can cause overheating damage. Plan the bench or floor layout around the 930 mm width plus 180 mm on each side.
The unit is protected internally by a 16.0 A fuse and draws 1.3 kW nominal at 220–240 V single-phase. The upstream circuit breaker and wiring must be sized for this continuous load; do not share the circuit with other high-draw equipment on the same phase.
Any heat-generating load inside the chamber — including accessory lighting such as the LED plant light module, which contributes about 220 W at full output — counts against the 410 W maximum heat compensation. Exceeding it prevents the chamber from holding setpoint at the low end of the 0–70 °C range.
Rack loading is limited to 40 kg each and the total permitted load is 200 kg. Distribute heavy items across multiple racks rather than concentrating mass on one shelf, and account for the weight of any accessory racks or light bars added to the chamber.
An electrical repeat inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 is required annually and after any maintenance or repair. Maintenance itself must be performed at least once a year by licensed electricians or BINDER-authorized experts; work by unauthorized personnel voids the warranty.
The chamber and any attached accessories are for indoor use only and must operate in an ambient temperature of +18 °C to +32 °C. After transport or storage at temperatures down to −10 °C, allow at least one hour at the installation site before start-up to avoid condensation.
Selection & Integration Q&A
All KB siblings share the 0–70 °C range, so select on volume and load: the KB 260 offers 262 L and 200 kg permitted load with a 656 mm interior width. Choose the KB 130 for smaller batches or the KB 470 when 262 L is insufficient; the 260 balances bench footprint (930 mm wide) against capacity.
The 230 V variant (KB260-230V, Art.-No. 9020-0473) runs on 220–240 V, 1~, 50 Hz at 1.3 kW with a CEE 7/7 plug and a 16.0 A unit fuse; size the branch circuit accordingly. For 120 V sites order the KB260UL-120V (Art.-No. 9020-0501) with NEMA 5-20 plug.
Yes, within the 410 W maximum heat compensation. The BINDER LED plant light module, for example, adds about 220 W at full output, leaving roughly 190 W of margin; beyond 410 W the chamber cannot hold setpoint at the low end of its 0–70 °C range.
Plan an annual electrical safety inspection per EN 50678/VDE 0701 and EN 50699/VDE 0702 plus yearly maintenance by BINDER-authorized personnel. If the LED plant light accessory is used, its CR1225 controller battery and LED bars (replace after ~25,000 h or 6 years) are wear items not included with the base KB 260.