BINDER BD 260
BINDER BD 260 — Incubators with Temperature 5…100 °C.
The BD 260 is a 253 L natural-convection incubator with a +5 to 100 °C working range, 0.2 K fluctuation and 0.3 K uniformity, sized between the BD 115 and BD 400 siblings. Its 0.85 kW single-phase 230 V design and 75 min heat-up to 100 °C suit standard 37 °C incubation and warm storage where forced-air airflow is undesirable.
Direct drop-in replacements
BINDER BD Series — Model Comparison & Selection
Full specifications
| Temperature | 5...100 °C |
| Heating-up time to 100 °C | 75 min |
| Interior volume | 253 L (BD260-230V / BD260UL-120V) |
| Load per rack | 40 kg (BD260-230V / BD260UL-120V) |
| Nominal power | 0.85 kW |
| Permitted load | 270 kg (BD260-230V / BD260UL-120V) |
| Temperature fluctuation | 0.2 K |
| Temperature uniformity | 0.3 K |
| Article Number mfr | 9010 |
| Recovery time after door was opened for 30 s at 37°C mfr | 16 min |
| Depth | 760 mm (BD260-230V / BD260UL-120V) |
| Height | 940 mm (BD260-230V / BD260UL-120V) |
| Width | 810 mm (BD260-230V / BD260UL-120V) |
| Power frequency | 50 Hz |
| Rated voltage | 230 V |
| Unit fuse | 8.0 A |
| Phase (Nominal voltage) mfr | 1 |
Description
Construction and series positioning
- Stainless-steel 1.4301 (AISI 304) inner chamber, pre-heating chamber and door interior; natural convection (no fan) distinguishes BD from the forced-convection BF line.
- 253 L interior (810 × 940 × 760 mm net) places this model between the BD 115 and BD 400; all BD siblings share the +5 to 100 °C range, so selection is driven by usable volume and load, not temperature capability.
- BD models carry temperature safety device class 3.1 (DIN 12880) and a class 1 overtemperature protective device tripping at 120 °C; controller display resolves to 0.1 °C.
Behavior under load and in operation
- Factory data: 0.2 K temperature fluctuation and 0.3 K uniformity; recovery to set-point after a 30 s door opening at 37 °C is 16 min.
- Heating from ambient to 100 °C takes 75 min at 0.85 kW nominal power.
- Permitted load is 270 kg total with 40 kg per rack; the usable volume must not be loaded beyond half, and samples need at least 10 % of interior dimensions as wall clearance to preserve airflow and uniformity.
Installation, connection and control
- Single-phase 230 V 1N~ 50 Hz supply, 8.0 A external chamber fuse (T 5×20 mm, 250 V); the UL variant BD260UL-120V uses 120 V 1N~ 60 Hz with a NEMA 5-15 plug.
- IEC connector plug with shockproof plug; IP 20 housing, pollution degree 2, over-voltage category II (IEC 61010-1).
- Microprocessor controller with set-point entry, ramp and timer functions; safety controller set-point range 10–100 °C (0.1° resolution), set 2–5 °C above the process set-point.
- Optional RS 422 interface for APT-COM 4, additional Pt100 sensor, analog temperature output and disconnectable audible over-temperature alarm.
Integration & Operating Notes
The chamber does not carry its own branch protection for this size; the 8.0 A T 5×20 mm / 250 V fuse is external. Size the circuit and fuse accordingly, and verify supply voltage stays within ±10 % of 230 V nominal before connection.
Natural convection depends on free air movement; overloading or placing samples closer than 10 % of the interior dimensions to walls prevents homogeneous temperature distribution and invalidates the 0.3 K uniformity figure. Respect 40 kg per rack and 270 kg total.
The safety controller acts as an absolute maximum limit; set it 2–5 °C above the process set-point and re-check after every set-point change. Its permissible range is 10–100 °C on BD. After an overtemperature trip the chamber must cool below the reset threshold before restart.
Operation outside +18 to +40 °C ambient, above 70 % r.h. non-condensing, or above 2000 m altitude is outside approved conditions. Do not install in unventilated recesses or explosive areas; the 260 size requires four people lifting at the lower corners.
Maintenance must be performed at least once a year by licensed electricians or BINDER-authorized experts; repeat electrical testing per EN 50678/VDE 0701 and EN 50699/VDE 0702 is recommended before first start and after repair. Replace the door gasket only when cold.
BD chambers can be hot-air disinfected at 100 °C / 212 °F, not sterilized at 190 °C as the ED/FD ovens can. Remove all flammable goods first. Use neutral cleaning agent 1002-0016 and disinfectant spray 1002-0022; avoid neutral cleaner on zinc-coated hinge parts and rear wall.
Selection & Integration Q&A
All BD siblings share +5 to 100 °C, so pick by volume and load: the 260 offers 253 L with 270 kg total and 40 kg per rack. Choose the 115 for smaller batches or the 400 when 253 L and the 810 mm width are insufficient; the 260 fits between them.
A 230 V 1N~ 50 Hz supply within ±10 %, protected by an external 8.0 A time-lag 5×20 mm fuse, connected via the IEC/shockproof plug. For remote monitoring, the optional RS 422 interface works with APT-COM 4; an analog temperature output and extra Pt100 are also optional.
Install indoors on a non-flammable surface at +18 to +40 °C, ≤70 % r.h. non-condensing, ≤2000 m altitude, with ventilation and no unventilated recess. Keep 10 % wall clearance and load no more than half the usable volume; the 260 needs four people to lift.
Schedule annual maintenance by BINDER-authorized personnel plus repeat electrical testing per EN 50678/50699. Consumables not included: 8.0 A T fuses, door gasket (replace cold), neutral cleaner 1002-0016 and disinfectant 1002-0022. RS 422/APT-COM 4, Pt100 and alarm are options.