Peter Huber Kältemaschinenbau CS 200 by Van der Heijden
Peter Huber Kältemaschinenbau CS 200 by Van der Heijden — Recirculating chillers with Noise level 78 dB.
The CS 200 is a 37-litre-bath recirculating chiller in the Cs Chiller series, operating from -20 to 15 °C with a 105 l/min pump at 4.7 bar. It is the largest sibling, distinguished by a 225–245 l fill volume and 510 kg mass. It serves process cooling loops requiring high flow and substantial fluid inventory.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| CS 200 by Van der Heijden Current | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 100 by Van der Heijden | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200-H by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 75 by Van der Heijden | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 25 | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550 OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
| Huber LCS 80 | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
Full specifications
| Noise level | 78 dB(A) |
| Bath volume | 37 l |
| Maximum delivery flow rate | 105 l/min (also 4, 7 bar pump pressure) |
| Minimum fill volume | 225 l |
| Pump connection | G1 AG male |
| Temperature range | -20...15 °C |
| Weight | 510 kg |
| Current consumption | 23 A (max) |
| Power supply | 400V 3~ 50Hz |
| Digital interface | RS232 |
| Ambient temperature limit | 5...32 °C |
| Protection rating | IP52 |
| Safety class | I / NFL |
Description
Construction and series positioning
The CS 200 is a circulating bath chiller with an internal bath volume of 37 l and a total system fill capacity of 225–245 l. It is the largest model in the Cs Chiller series, above the CS 100, CS 100-H, CS 125 and CS 125-H, which are lighter and quieter (70–75 dB(A) versus 78 dB(A) for the CS 200). The unit weighs 510 kg and is supplied with a 400 V 3~ 50 Hz supply, drawing up to 23 A and requiring 3×32 A fuses. The pump connection is G1 AG male, and the unit is protected to IP52.
Working range and media
- Temperature range: -20 to 15 °C.
- Recommended thermofluid: water–monoethylene glycol 50:50.
- Safety classification I/NFL per DIN 12876 restricts use with flammable liquids.
- Refrigerant R-449A (A1, H280), 12 kg charge (16.76 t CO2 equivalent).
- Cooling capacity is rated at 20 °C ambient and derates at higher ambient temperatures; selection must use actual site ambient.
Installation and operation
The chiller requires a 3-phase 400 V 50 Hz supply with 3×32 A fuses; devices under 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site. Voltage and frequency tolerances are interdependent: -5% voltage with +2% frequency is not allowed, while -5% voltage with -2% frequency is allowed. Ambient temperature must be 5–32 °C. Flow rate is adjusted via a manual bypass valve on the backside of the chiller. The unit emits Class A, Group 1 disturbances per EN55011, which may require additional EMC measures in sensitive environments. Space requirements around the 1400×1000×1800 mm unit must be respected for airflow and maintenance access.
Integration & Operating Notes
The chiller draws up to 23 A per phase and requires 3×32 A fuses. The electrical installation must be sized for this current and protection. A plug is not supplied for three-phase devices under 63 A, so a suitable plug must be provided on site.
A -5% voltage combined with +2% frequency is not allowed, while -5% voltage with -2% frequency is allowed. Site power quality must be checked against these combined tolerances to avoid invalid supply conditions.
Output data is valid for 20 °C room temperature. If ambient temperature rises, cooling capacity may drop, so selection must account for actual site ambient conditions to avoid undersizing.
The unit is rated IP52 and must be installed in ambient temperatures between 5 °C and 32 °C. Operation outside this range risks invalid performance or damage.
The recommended thermofluid is a 50:50 water–monoethylene glycol mixture, which must be used for proper operation and to protect the system. The internal tank holds between 225 l and 245 l, so system volume and expansion must be planned within this range.
The flow rate can be adjusted via a manual bypass valve on the backside of the chiller, allowing balancing of the circuit to match process requirements. The pump delivers up to 105 l/min at 4.7 bar.
Space requirements must be respected as per operating conditions, so clearance around the 1400×1000×1800 mm unit must be planned for airflow, maintenance access, and safe operation.
The equipment emits Class A, Group 1 disturbances per EN55011, which may require additional EMC measures in residential or sensitive environments.
Selection & Integration Q&A
Choose the CS 200 when the process requires a large fluid inventory (225–245 l fill) and high flow (105 l/min at 4.7 bar). The CS 100 and CS 125 have smaller capacities and lower noise (70–75 dB(A)), but the CS 200 is the largest and heaviest (510 kg) in the series.
The CS 200 requires a 400 V 3~ 50 Hz supply with max current 23 A and 3×32 A fuses. Three-phase devices under 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site. Voltage and frequency tolerances are interdependent: -5% voltage with +2% frequency is not allowed.
Install in ambient temperatures between 5 °C and 32 °C. Cooling capacity is rated at 20 °C ambient and derates at higher temperatures. The unit is IP52 and requires clearance around its 1400×1000×1800 mm footprint for airflow and maintenance.
The base delivery includes the chiller with cable but no plug; a suitable 3-phase plug must be provided. The recommended thermofluid is water–monoethylene glycol 50:50, which must be supplied separately. No maintenance schedule is specified in the available documents; consult the operating manual for service intervals.