Peter Huber Kältemaschinenbau Huber CS 25
Peter Huber Kältemaschinenbau Huber CS 25 — Recirculating chillers with Noise level 60 dB.
The Huber CS 25 is a 37-litre recirculating chiller with a -20…15 °C working range, positioned as the smallest capacity unit in the Cs Chiller series. It uses R-449A refrigerant and a 50 l/min, 4.5 bar pump to serve process loops requiring moderate cooling near ambient. Its 208 V two-phase supply and IP20 rating suit indoor industrial installations.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| Huber CS 25 Current | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| CS 100 by Van der Heijden | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200 by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 200-H by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 75 by Van der Heijden | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550 OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
| Huber LCS 80 | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
Full specifications
| Noise level | 60 dB(A) |
| Bath volume | 37 l |
| Minimum fill volume | 24 l |
| Pump connection | G1/2 AG male |
| Temperature range | -20...15 °C |
| Weight | 121 kg |
| Power supply | 208V 2~ 60Hz |
| Digital interface | RS232 |
| Ambient temperature limit | 5...32 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
The CS 25 is the lowest-capacity model in the Cs Chiller family; sibling units (CS 100, CS 100-H, CS 125, CS 125-H) step up in size and noise level (70–75 dB(A) versus 60 dB(A) here). The 37-litre bath and 24-litre minimum fill define a compact hydraulic circuit, while the 121 kg weight and IP20 enclosure indicate a floor-standing indoor unit. The pump connection is G1/2 AG male, and flow is trimmed by a manual bypass valve on the rear panel.
Working range and media
- Temperature range: -20…15 °C, with a safety classification of I / NFL per DIN 12876.
- Recommended thermofluid: water–monoethylene glycol 50:50, which provides freeze protection across the lower end of the range.
- Refrigerant: R-449A (A1, H280), 2 kg charge, CO₂ equivalent 2.79 t.
- Cooling capacity is rated at 20 °C ambient and derates as room temperature rises; size the loop for the actual ambient, not the catalogue figure.
Installation and operation
- Supply: 208 V 2~ 60 Hz, 12.5 A max, 2×20 A fuses; voltage tolerance ±5% and frequency ±2%, but the combination of -5% voltage with +2% frequency is not permitted.
- Three-phase devices below 63 A ship with cable but no plug, so a site-supplied plug is required.
- Ambient limit: 5…32 °C.
- Interface: RS232 for remote monitoring/control.
- EMC: EN55011 Class A, Group 1 — may cause radio interference in residential areas.
Integration & Operating Notes
The supply tolerance envelope is ±5% voltage and ±2% frequency, but the corner case of -5% voltage together with +2% frequency is explicitly prohibited. Verify the site supply against both limits simultaneously before commissioning, not just each independently.
The unit is delivered with a power cable but without a plug because it falls under the 63 A three-phase threshold. The installer must procure and fit a plug rated for the 208 V 2~ 60 Hz, 12.5 A supply and protect the circuit with 2×20 A fuses.
The recommended heat-transfer fluid is a 50:50 water–monoethylene glycol mixture. This concentration provides freeze protection down to the -20 °C lower limit and maintains heat transfer; substituting water alone risks freezing and poor performance at the cold end of the range.
Published cooling capacity is valid at 20 °C room temperature. If the installation space runs warmer (up to the 32 °C maximum), available cooling drops, so the loop heat load must be checked against the derated capacity rather than the catalogue value.
The refrigerant charge is 2 kg R-449A with a CO₂ equivalent of 2.79 t. This figure must be logged for periodic leak inspection and F-gas reporting obligations; R-449A is classified A1 with GHS hazard H280 (pressurized gas), so handling requires appropriate precautions.
The datasheet lists RS232 as the interface. Integrators planning supervisory control should provide an RS232 port or converter on the host side; no Ethernet or fieldbus option is stated for this model, so do not assume one is present.
Selection & Integration Q&A
Pick the CS 25 when the heat load fits its 37-litre bath and -20…15 °C range and low noise (60 dB(A)) matters. The CS 100/125 siblings are larger, noisier units (70–75 dB(A)) for higher duties; the CS 25 is the compact end of the series.
The pump connection is G1/2 AG male, so match it with G1/2 female fittings. Ensure the external circuit pressure drop is compatible with the pump's 50 l/min at 4.5 bar, and fill with at least 24 litres of 50:50 water–monoethylene glycol.
The unit ships with a power cable but no plug (three-phase below 63 A), so a site-supplied plug is needed. Thermofluid (50:50 water–monoethylene glycol) and process-side G1/2 fittings are also not part of the chiller delivery.