Peter Huber Kältemaschinenbau CS 200-H by Van der Heijden
Peter Huber Kältemaschinenbau CS 200-H by Van der Heijden — Recirculating chillers with Noise level 78 dB.
The CS 200-H is a 37-litre-bath, air-cooled recirculating chiller with a 6 kW heater and a 105 l/min pump, operating from -20 to 85 °C on a 400 V three-phase supply. It is the largest of the CS series, distinguished by its 225–245 l loop volume and 78 dB(A) sound level. It serves as a central temperature-control unit for large fluid circuits requiring both heating and cooling.
Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Minimum fill volume, m³ | Power supply | Pump connection | Temperature range, °C |
|---|---|---|---|---|---|---|
| CS 200-H by Van der Heijden Current | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–85 |
| CS 100 by Van der Heijden | 70 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 100-H by Van der Heijden | 71 | 5–32 | 0.175 | 400V 3~ 50Hz | G3/4 AG male | -20–85 |
| CS 200 by Van der Heijden | 78 | 5–32 | 0.225 | 400V 3~ 50Hz | G1 AG male | -20–15 |
| CS 20-H by Van der Heijden | 57 | 5–32 | 0.024 | 230V 1~ 50Hz | G3/8 AG male | -20–85 |
| CS 25 by Van der Heijden | 60 | 5–32 | 0.024 | 230V 1~ 50Hz | G1/2 AG male | -20–15 |
| CS 50 by Van der Heijden | 63 | 5–32 | 0.1 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| CS 75 by Van der Heijden | 66 | 5–32 | 0.16 | 400V 3~ 50Hz | G3/4 AG male | -20–15 |
| Huber CS 200-H | 78 | 5–32 | 0.225 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 25 | 60 | 5–32 | 0.024 | 208V 2~ 60Hz | G1/2 AG male | -20–15 |
| Huber CS 250HT OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G3/4 AG male | 10–22 |
| Huber CS 330-H OD | 78 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550-H OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–85 |
| Huber CS 550 OD | 79 | -20–50 | 0.16 | 460V 3~ 60Hz | G1 AG male | -20–15 |
| Huber LCS 80 | 77 | -20–50 | 0.04 | 460V 3~ 60Hz | G1 AG male | -45–15 |
Full specifications
| Noise level | 78 dB(A) |
| Bath volume | 37 l |
| Heating capacity | 6 kW |
| Maximum delivery flow rate | 105 l/min (also 4, 7 bar pump pressure) |
| Minimum fill volume | 225 l |
| Pump connection | G1 AG male |
| Temperature range | -20...85 °C |
| Weight | 515 kg |
| Current consumption | 23 A (max.) |
| Power supply | 400V 3~ 50Hz |
| Digital interface | RS232 |
| Ambient temperature limit | 5...32 °C |
| Protection rating | IP52 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The CS 200-H is an immersion-circulator chiller with a 37 l internal bath and a minimum loop fill of 225 l (maximum 245 l).
- It is the largest sibling in the CS series; the CS 100, CS 100-H, CS 125 and CS 125-H are smaller and quieter (70–75 dB(A) versus 78 dB(A) for this model).
- The condenser is air-cooled with a built-in high-efficiency fan motor; refrigerant is R-449A (A1, H280), 12 kg, CO2 equivalent 16.76 t.
- Hydraulic connection is a G1 male thread; flow is trimmed by a manual bypass valve on the rear panel.
Operating behaviour
- Working range is -20 to 85 °C with 6 kW heating capacity and a maximum delivery flow of 105 l/min at 4–7 bar pump pressure.
- Cooling capacity is rated at 20 °C room temperature and derates as ambient rises; the permitted ambient window is 5–32 °C.
- Recommended heat-transfer fluid is a 50:50 water–monoethylene glycol mixture.
- Electrical demand is 23 A maximum on a 400 V 3~ 50 Hz supply with a 3×32 A fuse.
Installation and control
- Three-phase units below 63 A are supplied with a cable but no plug; the customer must fit the plug.
- Voltage and frequency tolerances are coupled: ±5 % voltage only with ±2 % frequency; -5 % voltage with +2 % frequency is not allowed.
- The unit is Class A, Group 1 per EN55011 and IP52; it must not be exposed to water jets or immersion.
- An RS232 interface is provided for remote control/monitoring.
Integration & Operating Notes
The chiller accepts ±5 % voltage only when frequency stays within ±2 %, and the combination of -5 % voltage with +2 % frequency is explicitly forbidden. Verify the site supply quality against EN60034-1 before commissioning to avoid compressor or pump damage.
Because the unit draws 23 A (below 63 A), it ships with a cable but without a plug. The installing electrician must select and fit a plug rated for the 3×32 A fuse protection and the site's socket standard.
The tank filling capacity is specified as a minimum of 225 l and a maximum of 245 l. Size the external circuit and expansion volume so the total fill lands in this window; underfilling risks pump cavitation and overheating, overfilling risks overflow.
The recommended thermofluid is a 50:50 water–monoethylene glycol mixture. This protects against freezing at the -20 °C lower limit and maintains heat-transfer performance; other fluids may change viscosity, pump load and cooling capacity.
The condenser is air-cooled with a high-efficiency fan. Dust and debris on the fins reduce heat rejection and cooling capacity; schedule cleaning according to site dust load and monitor capacity drift as an indicator.
A manual bypass valve on the back of the chiller allows the delivery flow to be matched to the external circuit's resistance. Adjust it after installation to achieve the required pressure/flow point within the 105 l/min maximum and 4–7 bar pump pressure.
The unit is classified Class A, Group 1 under EN55011. It is intended for industrial environments; if installed near residential or sensitive electronics, additional EMC filtering or separation may be required.
Selection & Integration Q&A
Pick the CS 200-H when the circuit needs a 225–245 l fill volume, 6 kW heating and up to 105 l/min flow. The CS 100/125 siblings are smaller and quieter (70–75 dB(A)) but cannot serve large loops; choose them for lower volume and acoustic limits.
Provide G1 female fittings for the pump's G1 male thread, a 400 V 3~ 50 Hz supply protected at 3×32 A, and a customer-supplied plug (cable included, plug not). Fill with 50:50 water–monoethylene glycol within 225–245 l.
Install in 5–32 °C ambient with free air flow to the air-cooled condenser; capacity is rated at 20 °C and derates above it. IP52 allows dripping water but not jets or immersion. Keep supply within ±5 % voltage only with ±2 % frequency.
Base delivery includes the cable but no plug; the customer supplies the plug and the 50:50 water–glycol fluid. Periodically clean the air-cooled condenser to sustain capacity. No other consumables or accessories are specified in the datasheet.