Peter Huber Kältemaschinenbau CS 200 by Van der Heijden
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau CS 200 by Van der Heijden

Peter Huber Kältemaschinenbau CS 200 by Van der Heijden — Recirculating chillers with Noise level 78 dB.

The CS 200 is a 37-litre-bath recirculating chiller in the Cs Chiller series, operating from -20 to 15 °C with a 105 l/min pump at 4.7 bar. It is the largest sibling, distinguished by a 225–245 l fill volume and 510 kg mass. It serves process cooling loops requiring high flow and substantial fluid inventory.

Noise level
78 dB

Peter Huber Kältemaschinenbau Cs Chiller Series — Model Comparison & Selection

Model Noise level, dBAmbient temperature limit, °CMinimum fill volume, m³Power supplyPump connectionTemperature range, °C
CS 200 by Van der Heijden Current 785–320.225400V 3~ 50HzG1 AG male-20–15
CS 100 by Van der Heijden 705–320.16400V 3~ 50HzG3/4 AG male-20–15
CS 100-H by Van der Heijden 715–320.175400V 3~ 50HzG3/4 AG male-20–85
CS 200-H by Van der Heijden 785–320.225400V 3~ 50HzG1 AG male-20–85
CS 20-H by Van der Heijden 575–320.024230V 1~ 50HzG3/8 AG male-20–85
CS 25 by Van der Heijden 605–320.024230V 1~ 50HzG1/2 AG male-20–15
CS 50 by Van der Heijden 635–320.1400V 3~ 50HzG3/4 AG male-20–15
CS 75 by Van der Heijden 665–320.16400V 3~ 50HzG3/4 AG male-20–15
Huber CS 200-H 785–320.225460V 3~ 60HzG1 AG male-20–85
Huber CS 25 605–320.024208V 2~ 60HzG1/2 AG male-20–15
Huber CS 250HT OD 78-20–500.16460V 3~ 60HzG3/4 AG male10–22
Huber CS 330-H OD 78-20–500.16460V 3~ 60HzG1 AG male-20–85
Huber CS 550-H OD 79-20–500.16460V 3~ 60HzG1 AG male-20–85
Huber CS 550 OD 79-20–500.16460V 3~ 60HzG1 AG male-20–15
Huber LCS 80 77-20–500.04460V 3~ 60HzG1 AG male-45–15

Full specifications

Core Performance & Functional Specifications
Noise level 78 dB(A)
Bath volume 37 l
Maximum delivery flow rate 105 l/min (also 4, 7 bar pump pressure)
Minimum fill volume 225 l
Pump connection G1 AG male
Temperature range -20...15 °C
Dimensions, Weight & Mechanical Design
Weight 510 kg
Electrical, Power & Drive Specifications
Current consumption 23 A (max)
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Digital interface RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...32 °C
Protection rating IP52
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

The CS 200 is a circulating bath chiller with an internal bath volume of 37 l and a total system fill capacity of 225–245 l. It is the largest model in the Cs Chiller series, above the CS 100, CS 100-H, CS 125 and CS 125-H, which are lighter and quieter (70–75 dB(A) versus 78 dB(A) for the CS 200). The unit weighs 510 kg and is supplied with a 400 V 3~ 50 Hz supply, drawing up to 23 A and requiring 3×32 A fuses. The pump connection is G1 AG male, and the unit is protected to IP52.

Working range and media

Installation and operation

The chiller requires a 3-phase 400 V 50 Hz supply with 3×32 A fuses; devices under 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site. Voltage and frequency tolerances are interdependent: -5% voltage with +2% frequency is not allowed, while -5% voltage with -2% frequency is allowed. Ambient temperature must be 5–32 °C. Flow rate is adjusted via a manual bypass valve on the backside of the chiller. The unit emits Class A, Group 1 disturbances per EN55011, which may require additional EMC measures in sensitive environments. Space requirements around the 1400×1000×1800 mm unit must be respected for airflow and maintenance access.

Integration & Operating Notes

Electrical
Supply must be 400 V 3~ 50 Hz with 3×32 A fusing

The chiller draws up to 23 A per phase and requires 3×32 A fuses. The electrical installation must be sized for this current and protection. A plug is not supplied for three-phase devices under 63 A, so a suitable plug must be provided on site.

Technical Datasheet, Specifications
Electrical
Voltage and frequency tolerances are interdependent

A -5% voltage combined with +2% frequency is not allowed, while -5% voltage with -2% frequency is allowed. Site power quality must be checked against these combined tolerances to avoid invalid supply conditions.

Technical Datasheet, Specifications
Process Limits
Cooling capacity derates above 20 °C ambient

Output data is valid for 20 °C room temperature. If ambient temperature rises, cooling capacity may drop, so selection must account for actual site ambient conditions to avoid undersizing.

Technical Datasheet, Overview
Process Limits
Ambient temperature must stay within 5–32 °C

The unit is rated IP52 and must be installed in ambient temperatures between 5 °C and 32 °C. Operation outside this range risks invalid performance or damage.

Technical Datasheet, Specifications
Cooling & Media
Use water–monoethylene glycol 50:50 as thermofluid

The recommended thermofluid is a 50:50 water–monoethylene glycol mixture, which must be used for proper operation and to protect the system. The internal tank holds between 225 l and 245 l, so system volume and expansion must be planned within this range.

Technical Datasheet, Operation
Control & I/O
Flow adjusted via manual bypass valve on rear

The flow rate can be adjusted via a manual bypass valve on the backside of the chiller, allowing balancing of the circuit to match process requirements. The pump delivers up to 105 l/min at 4.7 bar.

Technical Datasheet, Operation
Mounting
Respect space requirements around the unit

Space requirements must be respected as per operating conditions, so clearance around the 1400×1000×1800 mm unit must be planned for airflow, maintenance access, and safe operation.

Technical Datasheet, Installation
Compliance
Class A, Group 1 EMC disturbances may require filtering

The equipment emits Class A, Group 1 disturbances per EN55011, which may require additional EMC measures in residential or sensitive environments.

Technical Datasheet, Compliance

Selection & Integration Q&A

When should I choose the CS 200 over the smaller CS 100 or CS 125 models?

Choose the CS 200 when the process requires a large fluid inventory (225–245 l fill) and high flow (105 l/min at 4.7 bar). The CS 100 and CS 125 have smaller capacities and lower noise (70–75 dB(A)), but the CS 200 is the largest and heaviest (510 kg) in the series.

What are the electrical supply and protection requirements for the CS 200?

The CS 200 requires a 400 V 3~ 50 Hz supply with max current 23 A and 3×32 A fuses. Three-phase devices under 63 A are supplied with cable but without a plug, so a suitable plug must be provided on site. Voltage and frequency tolerances are interdependent: -5% voltage with +2% frequency is not allowed.

What ambient and installation limits apply to the CS 200?

Install in ambient temperatures between 5 °C and 32 °C. Cooling capacity is rated at 20 °C ambient and derates at higher temperatures. The unit is IP52 and requires clearance around its 1400×1000×1800 mm footprint for airflow and maintenance.

What maintenance and accessories are required that are not included in the base delivery?

The base delivery includes the chiller with cable but no plug; a suitable 3-phase plug must be provided. The recommended thermofluid is water–monoethylene glycol 50:50, which must be supplied separately. No maintenance schedule is specified in the available documents; consult the operating manual for service intervals.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
CS 200 Circulating Bath — Technical Datasheet
Datasheet ·164,8 КБ ·2 pp.
View PDF