Peter Huber Kältemaschinenbau Petite Fleur w Dynamisches
Peter Huber Kältemaschinenbau Petite Fleur w Dynamisches — Temperature control units.
Hydraulically sealed circulator with a thermally passive expansion tank, rated for externally closed loops from -40 to 200 °C. The water-cooled 'w' variant uses R-290 (0.06 kg) and requires 2–6 bar cooling-water differential pressure. It suits precise temperature control where low-temperature cooling capacity is modest (0.04 kW at -40 °C).
Peter Huber Kältemaschinenbau Unistate Bis 45C Series — Model Comparison & Selection
| Model | Noise level, dB | Display resolution | Power supply | Pump connection | Pump type | Temperature range, °C |
|---|---|---|---|---|---|---|
| Petite Fleur w Dynamisches Current | — | 0, 01 | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Grande Fleur Dynamisches | — | — | — | — | — | — |
| Grande Fleur w Dynamisches | — | 0, 01 | 208-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -40–200 |
| Grande Fleur w-eo Dynamisches | — | — | — | — | — | — |
| Petite Fleur-eo Dynamisches | 58 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M16x1 AG male | Pressure pump, variable | -40–200 |
| Unistat 410w Dynamisches | 61 | 0, 01 K | 220-240V 1~/2~ 50/60Hz | M24x1, 5 AG male | Pressure pump, variable | -45–250 |
| Unistat 425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat 430w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P405w Dynamisches | — | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st | -45–250 |
| Unistat P425 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P425w Dynamisches | 61 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430 Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
| Unistat P430w Dynamisches | 65 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | -40–250 |
Full specifications
| Control output | POKO ONE |
| Expansion volume | 2 l |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | -40...200 °C |
| Weight | 47 kg |
| Current consumption | 11 A (max) |
| Fuse rating | 16 A |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 26 л/час (at 15°C, flow -20°C) at 15°C, flow 0°C: 34 l/h |
| Cooling water differential pressure | 2 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Hydraulically sealed circulation circuit with an atmospheric, thermally passive expansion tank (2 l), which prevents heat-transfer-fluid vapour formation and moisture absorption.
- Water-cooled condenser ('w' suffix) instead of an air-cooled condenser; the sibling Grande Fleur models differ in size and cooling configuration, while this Petite Fleur w is the compact water-cooled unit.
- Refrigerant R-290 (A3, H220), charge 0.06 kg; safety class III / FL.
- Pilot ONE controller with POKO ONE control output; Pt100 external sensor input; interfaces Ethernet, USB host/device and RS232.
Behavior under load and media
- Temperature range -40…200 °C with 0.01 K display resolution.
- Cooling power with ethanol falls from 0.45 kW at 0 °C to 0.04 kW at -40 °C, so low-temperature operation has very limited heat removal capacity.
- Variable-speed pressure pump delivers up to 25 l/min at a maximum delivery pressure of 0.9 bar; external circuit pressure drop must be checked against this curve.
- Heat-transfer fluid viscosity must not exceed 50 mm²/s at the lowest working temperature; different fluid types must never be mixed and the circuit must be rinsed when changing fluid type.
- Minimum filling capacity 1.5 l; expansion volume 2 l.
Installation, connection and operation
- Cooling-water connections G1/2 male; differential pressure at the connection must be at least 2 bar and no more than 6 bar; intake water temperature 5–20 °C; consumption 34 l/h at 15 °C with 0 °C flow and 26 l/h at 15 °C with -20 °C flow.
- Power supply 220–240 V, 1~/2~, 50/60 Hz, max. current 11 A, 16 A fuse; three-phase devices below 63 A are supplied with cable but without a plug.
- Voltage/frequency tolerances ±5 % / ±2 %, but -5 % voltage combined with +2 % frequency is not allowed.
- Ambient temperature 5–40 °C; protection rating IP20; EN55011 Class A, Group 1 (may cause radio interference in residential areas).
- Circulation flow must connect to the lower port of the application and return to the higher port to vent air bubbles; power cables longer than 3 m must not be used so the unit can be disconnected from the mains.
Integration & Operating Notes
Below 2 bar the condenser receives insufficient flow and cooling performance collapses; above 6 bar the water-cooled circuit and fittings are overstressed. Verify the site supply at the G1/2 male connection before commissioning.
Operation outside this window risks condensation inside the unit or loss of rated cooling capacity. If the cooling water is below the dew point, pipes inside the unit must be insulated to prevent condensation.
The supply tolerances are ±5 % voltage and ±2 % frequency, but the combination of -5 % voltage and +2 % frequency is explicitly not allowed because it can overload the compressor and pump. Check the site supply against both limits simultaneously.
Devices with current consumption below 63 A are supplied with a cable only, so the site must provide a suitable plug and a 16 A fused supply. Power cables longer than 3 m must not be used so the unit can always be disconnected from the mains.
The responsible body must install a condensation-water / thermal-fluid drip tray below the temperature control unit. Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation.
The unit must not be installed or started in an ATEX zone without an Ex px cabinet. For natural-refrigerant units, if the charge exceeds 8 g per m³ of room air, a calibrated gas warning sensor is mandatory; units with more than 1 kg refrigerant must not be installed below ground level.
The circulation flow from the unit must attach to the lower connection point of the application and the return to the higher connection point, so that air bubbles can vent. Reversing these connections traps air and prevents proper circulation.
The cooling water supply must be shut off even for short downtimes such as overnight to avoid water damage and condensation risks. Electrical lines directly below the unit must be protected against liquid ingress.
Selection & Integration Q&A
Pick the Petite Fleur w for compact, externally closed loops needing -40…200 °C with modest cooling load (0.04 kW at -40 °C). Choose a Grande Fleur sibling when higher cooling capacity or a different cooling configuration is required; the Petite Fleur w is the water-cooled compact unit with 0.06 kg R-290.
Provide cooling water at 5–20 °C with 2–6 bar differential pressure at the G1/2 male connections (34 l/h at 0 °C flow, 26 l/h at -20 °C). Electrical: 220–240 V, 1~/2~, 50/60 Hz, max. 11 A, 16 A fuse; three-phase units come with cable but no plug.
Ambient 5–40 °C, IP20, EN55011 Class A Group 1. Install a drip tray below the unit, protect cables below against condensation, do not install in an ATEX zone without an Ex px cabinet, and keep power cables ≤3 m for disconnection.
The base delivery excludes the plug (three-phase units ship with cable only), the drip tray, and the heat-transfer fluid. The fluid must be selected for ≤50 mm²/s at the lowest temperature; never mix fluid types and rinse the circuit when changing fluid.